The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Enhancement of Vascular Structures in3D and 2D Angiographic Images
Abstract
A number of imaging techniques are being used for diagnosis and treatment of vascular pathologies like stenoses, aneurysms, embolisms, malformations and remodelings, which may affect a wide range of anatomical sites. For computer-aided detection and highlighting of potential sites of pathology or to improve visualization and segmentation, angiographic images are often enhanced by Hessian based filters. These filters aim to indicate elongated and/or rounded structures by an enhancement function based on Hessian eigenvalues. However, established enhancement functions generally produce a response, which exhibits deficiencies such as poor and non-uniform response for vessels of different sizes and varying contrast, at bifurcations and aneurysms. This may compromise subsequent analysis of the enhanced images. This paper has three important contributions: i) reviews several established enhancement functions and elaborates their deficiencies, ii) proposes a novel enhancement function, which overcomes the deficiencies of the established functions, and iii) quantitatively evaluates and compares the novel and the established enhancement functions on clinical image datasets of the lung, cerebral and fundus vasculatures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An introduction to ROC analysis
Fawcett, T. (2006) · Pattern Recognition Letters · doi:10.1016/j.patrec.2005.10.010 · Cited by 21,879
Toward a quantitative assessment of diffusion anisotropy
Pierpaoli, C., & Basser, P. J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360612 · Cited by 2,405
Retinal Imaging and Image Analysis
Abramoff, M. D., Garvin, M. K., & Sonka, M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084567 · Cited by 1,439
Blood vessel segmentation methodologies in retinal images – A survey
Fraz, M. M., Remagnino, P., Hoppe, A., Uyyanonvara, B., Rudnicka, A. R., Owen, C. G., & Barman, S. A. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2012.03.009 · Cited by 1,001
A review of 3D vessel lumen segmentation techniques: Models, features and extraction schemes
Lesage, D., Angelini, E. D., Bloch, I., & Funka-Lea, G. (2009) · Medical Image Analysis · doi:10.1016/j.media.2009.07.011 · Cited by 920
Retinal vessel extraction by matched filter with first-order derivative of Gaussian
Zhang, B., Zhang, L., Zhang, L., & Karray, F. (2010) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2010.02.008 · Cited by 505
Odstrcilik, J., Kolar, R., Budai, A., Hornegger, J., Jan, J., Gazarek, J., Kubena, T., Cernosek, P., Svoboda, O., & Angelopoulou, E. (2013) · IET Image Processing · doi:10.1049/iet-ipr.2012.0455 · Cited by 472
Model-Based Detection of Tubular Structures in 3D Images
Krissian, K., Malandain, G., Ayache, N., Vaillant, R., & Trousset, Y. (2000) · Computer Vision and Image Understanding · doi:10.1006/cviu.2000.0866 · Cited by 404
Li, Q., Sone, S., & Doi, K. (2003) · Medical Physics · doi:10.1118/1.1581411 · Cited by 349
Tissue classification based on 3D local intensity structures for volume rendering
Sato, Y., Westin, C., Bhalerao, A., Nakajima, S., Shiraga, N., Tamura, S., & Kikinis, R. (2000) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/2945.856997 · Cited by 338
Vessel enhancing diffusionA scale space representation of vessel structures
MANNIESING, R., VIERGEVER, M., & NIESSEN, W. (2006) · Medical Image Analysis · doi:10.1016/j.media.2006.06.003 · Cited by 232
Villablanca, J. P., Jahan, R., Hooshi, P., et al. (2002) · PubMed · Cited by 229
Vessel tree reconstruction in thoracic CT scans with application to nodule detection
Gady Agam, B., Armato, S. G., & Wu, C. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.844167 · Cited by 174
Beyond Frangi: an improved multiscale vesselness filter
Jerman, T., Pernuš, F., Likar, B., & Špiclin, Ž. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2081147 · Cited by 100
Self-citationDiscriminative vessel segmentation in retinal images by fusing context-aware hybrid features
Cheng, E., Du, L., Wu, Y., Zhu, Y. J., Megalooikonomou, V., & Ling, H. (2014) · Machine Vision and Applications · doi:10.1007/s00138-014-0638-x · Cited by 93
Oriented Gaussian Mixture Models for Nonrigid 2D/3D Coronary Artery Registration
Baka, N., Metz, C., Schultz, C. J., van Geuns, R., Niessen, W. J., & van Walsum, T. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2300117 · Cited by 79
Automatic segmentation, detection and quantification of coronary artery stenoses on CTA
Shahzad, R., Kirişli, H. A., Metz, C., Tang, H., Schaap, M., A, L. J. V. V., Niessen, W. J., & van Walsum, T. (2013) · International journal of cardiac imaging · doi:10.1007/s10554-013-0271-1 · Cited by 79
Automatic Hepatic Vessel Segmentation Using Graphics Hardware
Erdt, M., Raspe, M., & Suehling, M. (2008) · Lecture notes in computer science · doi:10.1007/978-3-540-79982-5_44 · Cited by 64
A Novel Approach for Detection of Tubular Objects and Its Application to Medical Image Analysis
Bauer, C. H., & Bischof, H. (2008) · Lecture notes in computer science · doi:10.1007/978-3-540-69321-5_17 · Cited by 60
Analysis of Distance/Similarity Measures for Diffusion Tensor Imaging
Peeters, T. H. J. M., Rodrigues, P., Vilanova, A., & Romeny, B. M. T. H. (2009) · Mathematics and visualization · doi:10.1007/978-3-540-88378-4_6 · Cited by 46
Mesenteric Vasculature-Guided Small Bowel Segmentation on 3-D CT
Zhang, W., Liu, J., Yao, J., Louie, A., Nguyen, T. B., Wank, S. A., Nowinski, W. L., & Summers, R. M. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2271487 · Cited by 46
Luu, H. M., Klink, C., Moelker, A. D., Niessen, W. J., & van Walsum, T. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/10/3905 · Cited by 41
Model-Based Vasculature Extraction From Optical Fluorescence Cryomicrotome Images
Goyal, A., Lee, J., Lamata, P., van den Wijngaard, J. P. H. M., van Horssen, P., Spaan, J. A. E., Siebes, M., Grau, V., & Smith, N. P. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2227275 · Cited by 37
Wiemker, R., Klinder, T., Bergtholdt, M., Meetz, K., Carlsen, I. C., & Bülow, T. (2012) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/tvcg.2012.136 · Cited by 36
A system to detect cerebral aneurysms in multimodality angiographic data sets
Hentschke, C. M., Beuing, O., Paukisch, H., Scherlach, C., Skalej, M., & Tönnies, K. D. (2014) · Medical Physics · doi:10.1118/1.4890775 · Cited by 30
Cost-effectiveness of CTA, MRA and DSA in patients with non-traumatic subarachnoid haemorrhage
Sailer, A. M., Grutters, J. P. C., Wildberger, J. E., Hofman, P. A. M., Wilmink, J. T., & van Zwam, W. H. (2013) · Insights into Imaging · doi:10.1007/s13244-013-0264-6 · Cited by 29
Stacked Multiscale Feature Learning for Domain Independent Medical Image Segmentation
Kiros, R., Popuri, K., Cobzaş, D., & Jägersand, M. (2014) · Lecture notes in computer science · doi:10.1007/978-3-319-10581-9_4 · Cited by 23
Model-Based Automated Extraction of Microtubules From Electron Tomography Volume
Jiang, M. X., Ji, Q., & McEwen, B. F. (2006) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2006.872042 · Cited by 17
Cited by
Transcranial ultrafast ultrasound localization microscopy of brain vasculature in patients
Demené, C., Robin, J., Dizeux, A., Heiles, B., Pernot, M., Tanter, M., & Perren, F. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00697-x · Cited by 370
Shipley, F. B., Dani, N., Xu, H., Deister, C., Cui, J., Head, J. P., Sadegh, C., Fame, R. M., Shannon, M. L., Flores, V. I., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.08.024 · Cited by 118
Chen, J., Ding, L., Viana, M. P., Lee, H., Sluezwski, M. F., Morris, B., Hendershott, M. C., Yang, R., Mueller, I. A., & Rafelski, S. M. (2018) · doi:10.1101/491035 · Cited by 99
Metadata
- Authors
- Jerman, T., Pernus, F., Likar, B., & Spiclin, Z.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2016-09
- Volume
- 35
- Issue
- 9
- Pages
- 2107-2118
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2334170987
- Cited by
- 294
- References
- 28
- FWCI
- 10.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.