CoChat

Automatic Quality Assessment of Echocardiograms Using Convolutional Neural Networks: Feasibility on the Apical Four-Chamber View

Abdi, Amir H., Luong, Christina, Tsang, Teresa, Allan, Gregory, Nouranian, Saman, Jue, John, Hawley, Dale, Fleming, Sarah, Gin, Ken, Swift, Jody, Rohling, Robert, Abolmaesumi, Purang · 2017 · IEEE Transactions on Medical Imaging
Cited by 137

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Echocardiography (echo) is a skilled technical procedure that depends on the experience of the operator. The aim of this paper is to reduce user variability in data acquisition by automatically computing a score of echo quality for operator feedback. To do this, a deep convolutional neural network model, trained on a large set of samples, was developed for scoring apical four-chamber (A4C) echo. In this paper, 6,916 end-systolic echo images were manually studied by an expert cardiologist and were assigned a score between 0 (not acceptable) and 5 (excellent). The images were divided into two independent training-validation and test sets. The network architecture and its parameters were based on the stochastic approach of the particle swarm optimization on the training-validation data. The mean absolute error between the scores from the ultimately trained model and the expert's manual scores was 0.71 ± 0.58. The reported error was comparable to the measured intra-rater reliability. The learned features of the network were visually interpretable and could be mapped to the anatomy of the heart in the A4C echo, giving confidence in the training result. The computation time for the proposed network architecture, running on a graphics processing unit, was less than 10 ms per frame, sufficient for real-time deployment. The proposed approach has the potential to facilitate the widespread use of echo at the point-of-care and enable early and timely diagnosis and treatment. Finally, the approach did not use any specific assumptions about the A4C echo, so it could be generalizable to other standard echo views.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2017.2690836

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 137

Metadata

Authors
Abdi, A. H., Luong, C., Tsang, T., Allan, G., Nouranian, S., Jue, J., Hawley, D., Fleming, S., Gin, K., Swift, J., Rohling, R., & Abolmaesumi, P.
Venue
IEEE Transactions on Medical Imaging
Published
2017-06
Volume
36
Issue
6
Pages
1221-1230
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2605159090
Cited by
137
References
5
FWCI
3.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automatic Quality Assessment of Echocardiograms Using Convolutional Neural Networks: Feasibility on the Apical Four-Chamber View. https://app.cochat.ai/papers/10.1109/tmi.2017.2690836
The paper
Abdi, A. H., Luong, C., Tsang, T., Allan, G., Nouranian, S., Jue, J., Hawley, D., Fleming, S., Gin, K., Swift, J., Rohling, R., & Abolmaesumi, P. (2017). Automatic Quality Assessment of Echocardiograms Using Convolutional Neural Networks: Feasibility on the Apical Four-Chamber View. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2017.2690836

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.