The DOI matches its Crossref record.
Implanted Antennas Inside a Human Body: Simulations, Designs, and Characterizations
Abstract
Antennas implanted in a human body are largely applicable to hyperthermia and biotelemetry. To make practical use of antennas inside a human body, resonance characteristics of the implanted antennas and their radiation signature outside the body must be evaluated through numerical analysis and measurement setup. Most importantly, the antenna must be designed with an in-depth consideration given to its surrounding environment. In this paper, the spherical dyadic Green's function (DGF) expansions and finite-difference time-domain (FDTD) code are applied to analyze the electromagnetic characteristics of dipole antennas and low-profile patch antennas implanted in the human head and body. All studies to characterize and design the implanted antennas are performed at the biomedical frequency band of 402-405 MHz. By comparing the results from two numerical methodologies, the accuracy of the spherical DGF application for a dipole antenna at the center of the head is evaluated. We also consider how much impact a shoulder has on the performance of the dipole inside the head using FDTD. For the ease of the design of implanted low-profile antennas, simplified planar geometries based on a real human body are proposed. Two types of low-profile antennas, i.e., a spiral microstrip antenna and a planar inverted-F antenna, with superstrate dielectric layers are initially designed for medical devices implanted in the chest of the human body using FDTD simulations. The radiation performances of the designed low-profile antennas are estimated in terms of radiation patterns, radiation efficiency, and specific absorption rate. Maximum available power calculated to characterize the performance of a communication link between the designed antennas and an exterior antenna show how sensitive receivers are required to build a reliable telemetry link.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wireless Body Area Networks: A Survey
Movassaghi, S., Abolhasan, M., Lipman, J., Smith, D., & Jamalipour, A. (2014) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2013.121313.00064 · Cited by 1,538
Optimal Frequency for Wireless Power Transmission Into Dispersive Tissue
Poon, A. S. Y., O'Driscoll, S., & Meng, T. H. (2010) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2010.2044310 · Cited by 469
Powering implantable and ingestible electronics
Yang, S., Sencadas, V., You, S. S., Jia, N. Z., Srinivasan, S. S., Huang, H., Ahmed, A. E., Liang, J. Y., & Traverso, G. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202009289 · Cited by 183
Chow, E., Morris, M., & Irazoqui, P. (2013) · IEEE Microwave Magazine · doi:10.1109/mmm.2013.2248586 · Cited by 111
Review on medical implantable antenna technology and imminent research challenges
Soliman, M. M., Chowdhury, M. E. H., Khandakar, A., Islam, M. T., Qiblawey, Y., Musharavati, F., & Zal Nezhad, E. (2021) · Sensors · doi:10.3390/s21093163 · Cited by 95
Metadata
- Authors
- Kim, J., & Rahmat-Samii, Y.
- Venue
- IEEE Transactions on Microwave Theory and Techniques
- Published
- 2004-08
- Volume
- 52
- Issue
- 8
- Pages
- 1934-1943
- ISSN
- 0018-9480 (ISSN-L)
- OpenAlex
- W2156005252
- Cited by
- 757
- References
- 0
- FWCI
- 10.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implanted Antennas Inside a Human Body: Simulations, Designs, and Characterizations. https://app.cochat.ai/papers/10.1109/tmtt.2004.832018
- The paper
- Kim, J., & Rahmat-Samii, Y. (2004). Implanted Antennas Inside a Human Body: Simulations, Designs, and Characterizations. IEEE Transactions on Microwave Theory and Techniques. https://doi.org/10.1109/tmtt.2004.832018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.