The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Frequency-tuning technique for remote detection of heartbeat and respiration using low-power double-sideband transmission in the ka-band
Abstract
A Ka-band transceiver using low-power double-sideband transmission to detect human heartbeat and respiration signals is demonstrated. The Ka-band electromagnetic wave offers higher detection sensitivity on small movement due to its shorter wavelength. Indirect-conversion receiver architecture is chosen to reduce the dc offset and 1/f noise that can degrade the signal-to-noise ratio and detection accuracy. Furthermore, the double-sideband signals at the transmitter output can be in quadrature by choosing a proper frequency separation to relieve the severe null point problem that occurs at high frequency. As a result,the detection accuracy is significantly improved with low transmitted power. This radar sensor system achieves better than 80% detection accuracy at a distance of 2.0 m with a combined transmitted power of only 12.5 /spl mu/W in both sidebands.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Droitcour, A. D., Boric-Lubecke, O., Lubecke, V. M., Lin, J., & Kovacs, G. T. A. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.823552 · Cited by 662
Self-citationChen, K.-M., Huang, Y., Zhang, J., & Norman, A. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.817625 · Cited by 445
Microwave sensing of physiological movement and volume change: A review
Lin, J. C. (1992) · Bioelectromagnetics · doi:10.1002/bem.2250130610 · Cited by 299
Self-citationA microwave radio for Doppler radar sensing of vital signs
Droitcour, A., Lubecke, V., Lin, J., & Boric-Lubecke, O. (2002) · 2001 IEEE MTT-S International Microwave Sympsoium Digest (Cat. No.01CH37157) · doi:10.1109/mwsym.2001.966866 · Cited by 252
Self-citationA digital signal processor for Doppler radar sensing of vital signs
Lohman, B., Borić-Lubecke, O., Lubecke, V. M., Ong, P. W., & Sondhi, M. M. (2002) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2002.1044188 · Cited by 107
Droitcour, A. D., Borić-Lubecke, O., Lubecke, V. M., & Lin, J. (2003) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2002.993075 · Cited by 105
Self-citationDevelopment of the ring sensor for healthcare automation
Yang, B.-H., & Rhee, S. (2000) · Robotics and Autonomous Systems · doi:10.1016/s0921-8890(99)00092-5 · Cited by 88
Range correlation effects on phase and amplitude noise
Budge, M. C., & Burt, M. P. (2002) · IEEE SoutheastCon · doi:10.1109/secon.1993.465731 · Cited by 79
Singh, M. C., & Ramachandran, G. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.81568 · Cited by 67
Cited by
A Review on Recent Advances in Doppler Radar Sensors for Noncontact Healthcare Monitoring
Li, C., Lubecke, V. M., Boric-Lubecke, O., & Lin, J. (2013) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2013.2256924 · Cited by 821
Self-citationArctangent Demodulation With DC Offset Compensation in Quadrature Doppler Radar Receiver Systems
Park, B.-K., Boric-Lubecke, O., & Lubecke, V. M. (2007) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2007.895653 · Cited by 604
Self-citationRandom Body Movement Cancellation in Doppler Radar Vital Sign Detection
Li, C., & Lin, J. (2008) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2008.2007139 · Cited by 448
Self-citationA Review on Recent Progress of Portable Short-Range Noncontact Microwave Radar Systems
Li, C., Peng, Z., Huang, T.-Y., Fan, T., Wang, F.-K., Horng, T.-S., Munoz-Ferreras, J.-M., Gomez-Garcia, R., Ran, L., & Lin, J. (2017) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2017.2650911 · Cited by 372
Self-citationRadar remote monitoring of vital signs
Li, C., Cummings, J., Lam, J., Graves, E., & Wu, W. (2009) · IEEE Microwave Magazine · doi:10.1109/mmm.2008.930675 · Cited by 255
Metadata
- Authors
- Xiao, Y., Lin, J., Boric-Lubecke, O., & Lubecke, M.
- Venue
- IEEE Transactions on Microwave Theory and Techniques
- Published
- 2006-05
- Volume
- 54
- Issue
- 5
- Pages
- 2023-2032
- ISSN
- 0018-9480 (ISSN-L)
- OpenAlex
- W2155445740
- Cited by
- 259
- References
- 9
- FWCI
- 8.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.