Efficient Four-Coil Wireless Power Transfer for Deep Brain Stimulation
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This paper demonstrates a closed-loop wireless power transfer (WPT) system for deep brain stimulation-implanted biomedical applications. A novel two-layer PCB FR4 coil design is proposed as a second coil for enlarging the WPT efficiency. High-efficiency implantable WPT technology was achieved by applying an inner dual-layer printed spiral coil (PSC) and outer helical coil and this coordinated with a T-type impedance-matching network. To reduce the loading effect, which lowers Q factor in implanted devices, four-coil WPT systems are recommended compared with two- or three-coil WPT systems. A practical four-coil system was implemented for verification, for which a dual-layer printed circuit board composed of a PSC, with a load loop on the other side of FR4, was designed and implemented around the system on a chip. PSCs for biomedical implants can be optimized by designing the geometric parameters. The implant coil occupies an area measuring 5 × 5 mm, and is implemented on both an FR4 board and an implantable flexible substrate with the optimized geometric parameters. Finally, the transmission efficiencies of using FR4 and flexible printed circuit boards, at a distance of 10 mm, were 19.1% and 14.8% through the air and 11.7% and 7.7% through the tissue, respectively, thus enabling the supply of milliwatts of power to the stimulation circuits, and successfully demonstrating the stimulation tissue model with a V/I output current of up to 180 μA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 1×
“Deep brain stimulation (DBS) [1], [2] is proven to be an effective therapeutic method for PD treatment, and it has reached the maturation stage of DBS test methods for substantially suppressing and alleviating tremors as well as dystonia resulting from PD [3], [4].”
BackgroundLee, H.-M., Kwon, K. Y., Li, W., & Ghovanloo, M. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2355814 · Cited by 161 · cited 1×
“Previous related research [9]–[12] has been limited to”
BackgroundZargham, M., & Gulak, P. G. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2328318 · Cited by 115
Cited by
All-in-one self-powered flexible microsystems based on triboelectric nanogenerators
Zhang, X.-S., Han, M., Kim, B., Bao, J.-F., Brugger, J., & Zhang, H. (2018) · Nano Energy · doi:10.1016/j.nanoen.2018.02.046 · Cited by 297
Magnetoelectric effect: principles and applications in biology and medicine– a review
Kopyl, S., Surmenev, R., Surmeneva, M., Fetisov, Y., & Kholkin, A. (2021) · Materials Today Bio · doi:10.1016/j.mtbio.2021.100149 · Cited by 202
Wireless power transfer approaches for medical implants: a review
Haerinia, M., & Shadid, R. (2020) · Signals · doi:10.3390/signals1020012 · Cited by 174
Near-field wireless power transfer used in biomedical implants: a comprehensive review
Mahmood, A. I., Gharghan, S. K., Eldosoky, M. A., & Soliman, A. M. (2022) · IET Power Electronics · doi:10.1049/pel2.12351 · Cited by 59
Lyu, H., Wang, J., La, J.-H., Chung, J. M., & Babakhani, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2852680 · Cited by 47
Metadata
- Authors
- Yang, C.-L., Chang, C.-K., Lee, S.-Y., Chang, S.-J., & Chiou, L.-Y.
- Venue
- IEEE Transactions on Microwave Theory and Techniques
- Published
- 2017-07
- Volume
- 65
- Issue
- 7
- Pages
- 2496-2507
- ISSN
- 0018-9480 (ISSN-L)
- 1557-9670
- OpenAlex
- W2606214413
- Cited by
- 96
- References
- 3
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.