The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Real-Time, Label-Free Detection of Biological Entities Using Nanowire-Based FETs
Abstract
Nanowire (NW)-based FETs are promising devices with potential applications ranging from health monitoring to drug discovery. In fact, these devices have demonstrated the ability to detect a variety of analytes such as particular DNA sequences, cancer biomarkers, and larger entities such as viruses. These sensor devices have also been used to monitor enzymatic activities and study the behavior of potential drug molecules. The detection of the analytes occurs with high specificity and sensitivity in reasonably short time. Here, we review the recent literature produced in the field of NW FET biosensors. We elaborate on the parameters that ultimately influence device performance such as methods of NW production, device dimensionality, and active measurement conditions. Significant progress has been made in this field of technology; however, it is often difficult to compare literature reports due to differences in both measurement conditions and data analysis. The standardization of certain active measurement conditions, such as the ionic strength of the analyte solutions, and manipulation of data are proposed to facilitate comparison between different NW biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Cancer nanotechnology: opportunities and challenges
Ferrari, M. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1566 · Cited by 4,558
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Importance of the Debye Screening Length on Nanowire Field Effect Transistor Sensors
Stern, E., Wagner, R., Sigworth, F. J., Breaker, R., Fahmy, T. M., & Reed, M. A. (2007) · Nano Letters · doi:10.1021/nl071792z · Cited by 806
Surface Charge Sensitivity of Silicon Nanowires: Size Dependence
Elfström, N., Juhasz, R., Sychugov, I., Engfeldt, T., Karlström, A. E., & Linnros, J. (2007) · Nano Letters · doi:10.1021/nl0709017 · Cited by 275
Cited by
Chen, K.-I., Li, B.-R., & Chen, Y.-T. (2011) · Nano Today · doi:10.1016/j.nantod.2011.02.001 · Cited by 645
Vollmer, F., & Yang, L. (2012) · nanoph · doi:10.1515/nanoph-2012-0021 · Cited by 546
Duan, X., Li, Y., Rajan, N. K., Routenberg, D. A., Modis, Y., & Reed, M. A. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.82 · Cited by 366
Recent advances in wide bandgap semiconductor biological and gas sensors
Pearton, S. J., Ren, F., Wang, Y.-L., Chu, B. H., Chen, K. H., Chang, C. Y., Lim, W., Lin, J., & Norton, D. P. (2010) · Progress in Materials Science · doi:10.1016/j.pmatsci.2009.08.003 · Cited by 286
Microfluidic-based biosensors toward point-of-care detection of nucleic acids and proteins
Choi, S., Goryll, M., Sin, L. Y. M., Wong, P. K., & Chae, J. (2011) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0638-8 · Cited by 270
Metadata
- Authors
- Curreli, M., Zhang, R., Ishikawa, F. N., Chang, H.-K., Cote, R. J., Zhou, C., & Thompson, M. E.
- Venue
- IEEE Transactions on Nanotechnology
- Published
- 2008-11
- Volume
- 7
- Issue
- 6
- Pages
- 651-667
- ISSN
- 1536-125X (ISSN-L)
- 1941-0085
- OpenAlex
- W2100606738
- Cited by
- 220
- References
- 5
- FWCI
- 8.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-Time, Label-Free Detection of Biological Entities Using Nanowire-Based FETs. https://app.cochat.ai/papers/10.1109/tnano.2008.2006165
- The paper
- Curreli, M., Zhang, R., Ishikawa, F. N., Chang, H.-K., Cote, R. J., Zhou, C., & Thompson, M. E. (2008). Real-Time, Label-Free Detection of Biological Entities Using Nanowire-Based FETs. IEEE Transactions on Nanotechnology. https://doi.org/10.1109/tnano.2008.2006165
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.