The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Surface-Modified Superparamagnetic Nanoparticles for Drug Delivery: Preparation, Characterization, and Cytotoxicity Studies
Abstract
Superparamagnetic iron oxide nanoparticles have been used for many years as magnetic resonance imaging (MRI) contrast agents or in drug delivery applications. In this study, a novel approach to prepare magnetic polymeric nanoparticles with magnetic core and polymeric shell using inverse microemulsion polymerization process is reported. Poly(ethyleneglycol) (PEG)-modified superparamagnetic iron oxide nanoparticles with specific shape and size have been prepared inside the aqueous cores of AOT/n-Hexane reverse micelles and characterized by various physicochemical means such as transmission electron microscopy (TEM), infrared spectroscopy, atomic force microscopy (AFM), vibrating sample magnetometry (VSM), and ultraviolet/visible spectroscopy. The inverse microemulsion polymerization of a polymerizable derivative of PEG and a cross-linking agent resulted in a stable hydrophilic polymeric shell of the nanoparticles. The results taken together from TEM and AFM studies showed that the particles are spherical in shape with core-shell structure. The average size of the PEG-modified nanoparticles was found to be around 40-50 nm with narrow size distribution. The magnetic measurement studies revealed the superparamagnetic behavior of the nanoparticles with saturation magnetization values between 45-50 electromagnetic units per gram. The cytotoxicity profile of the nanoparticles on human dermal fibroblasts as measured by standard 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay showed that the particles are nontoxic and may be useful for various in vivo and in vitro biomedical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mosmann, T. (1983) · Journal of Immunological Methods · doi:10.1016/0022-1759(83)90303-4 · Cited by 56,104
Fischer, D., Li, Y., Ahlemeyer, B., Krieglstein, J., & Kissel, T. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00445-3 · Cited by 2,329
Granqvist, C. G., & Buhrman, R. A. (1976) · Journal of Applied Physics · doi:10.1063/1.322870 · Cited by 1,613
Surface modification of superparamagnetic magnetite nanoparticles and their intracellular uptake
Zhang, Y., Kohler, N., & Zhang, M. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00267-8 · Cited by 1,264
Surface modification of nanoparticles to oppose uptake by the mononuclear phagocyte system
Storm, G., Belliot, S. O., Daemen, T., & Lasic, D. D. (1995) · Advanced Drug Delivery Reviews · doi:10.1016/0169-409x(95)00039-a · Cited by 877
Kim, D. K., Zhang, Y., Voit, W., Rao, K. V., & Muhammed, M. (2001) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(00)01224-5 · Cited by 772
Long circulating microparticulate drug carriers
Stolnik, S., Illum, L., & Davis, S. S. (1995) · Advanced Drug Delivery Reviews · doi:10.1016/0169-409x(95)00025-3 · Cited by 700
Chouly, C., Pouliquen, D., Lucet, I., Jeune, J. J., & Jallet, P. (1996) · Journal of Microencapsulation · doi:10.3109/02652049609026013 · Cited by 467
Long-circulating iron oxides for MR imaging
Weissleder, R., Bogdanov, A., Neuwelt, E. A., & Papisov, M. (1995) · Advanced Drug Delivery Reviews · doi:10.1016/0169-409x(95)00033-4 · Cited by 398
Preparation and Properties of Magnetite and Polymer Magnetite Nanoparticles
Dresco, P. A., Zaitsev, V. S., Gambino, R. J., & Chu, B. (1999) · Langmuir · doi:10.1021/la980971g · Cited by 373
Amiji, M., & Park, K. (1992) · Biomaterials · doi:10.1016/0142-9612(92)90128-b · Cited by 359
Zaitsev, V. S., Filimonov, D. S., Presnyakov, I. A., Gambino, R. J., & Chu, B. (1999) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1998.5993 · Cited by 310
Minireview Magnetically controlled targeted micro-carrier systems
Gupta, P. K., & Hung, C. T. (1989) · Life Sciences · doi:10.1016/0024-3205(89)90593-6 · Cited by 209
Weissleder, R., Lee, A. S., Khaw, B. A., Shen, T., & Brady, T. J. (1992) · Radiology · doi:10.1148/radiology.182.2.1732953 · Cited by 186
Preparation and characterization of monodisperse magnetite sols in microemulsion
Gobe, M., Kon-No, K., Kandori, K., & Kitahara, A. (1983) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(83)90411-3 · Cited by 175
Dunn, S. E., Brindley, A., Davis, S. S., Davies, M. C., & Illum, L. (1994) · Pharmaceutical Research · doi:10.1023/a:1018939521589 · Cited by 168
MR lymphography: study of a high-efficiency lymphotrophic agent.
Weissleder, R., Heautot, J. F., Schaffer, B., Nossiff, N. D., Papisov, M. I., Bogdanov, A. A., Jr., & Brady, T. J. (1994) · Radiology · doi:10.1148/radiology.191.1.8134576 · Cited by 120
Properties of Immobilized PEG Films and the Interaction with Proteins
Gölander, C.-G., Herron, J. N., Lim, K., Claesson, P. M., Stenius, P. J., & Andrade, J. D. (1992) · Springer eBooks · doi:10.1007/978-1-4899-0703-5_15 · Cited by 112
Liver MR imaging with iron oxides: toward consensus and clinical practice
Weissleder, R. (1994) · Radiology · doi:10.1148/radiology.193.3.7972790 · Cited by 101
Size Modulation of Polymeric Nanoparticles under Controlled Dynamics of Microemulsion Droplets
Munshi, N., De, T., & Maitra, A. (1997) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1997.4889 · Cited by 74
Cited by
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Synthesis and surface engineering of iron oxide nanoparticles for biomedical applications
Gupta, A. K., & Gupta, M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.10.012 · Cited by 6,771
Self-citationLewinski, N., Colvin, V., & Drezek, R. (2008) · Small · doi:10.1002/smll.200700595 · Cited by 2,810
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
Magnetic iron oxide nanoparticles: synthesis and surface functionalization strategies
Wu, W., He, Q., & Jiang, C. (2008) · Nanoscale Research Letters · doi:10.1007/s11671-008-9174-9 · Cited by 2,300
Metadata
- Authors
- Gupta, A. K., & Wells, S.
- Venue
- IEEE Transactions on Nanobioscience
- Published
- 2004-03
- Volume
- 3
- Issue
- 1
- Pages
- 66-73
- ISSN
- 1536-1241 (ISSN-L)
- OpenAlex
- W2150287384
- Cited by
- 634
- References
- 20
- FWCI
- 6.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.