The DOI matches its Crossref record.
A Matheematical Model for Positron-Emission Tomography Systems Having Time-of-Flight Measurements
Abstract
Improvements in high speed electronics and scintillation-crystal technology now permit usable differential time-of-flight measurements to be made in tomography systems that employ coincidence detection of the annihilation photons created with positron emitting radionuclides. A mathematical model for these new measurements is developed in this paper. Reconstruction algorithms and their signal-to-noise ratio performance are given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Deformable templates using large deformation kinematics
Christensen, G. E., Rabbitt, R. D., & Miller, M. I. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.536892 · Cited by 1,142
A Statistical Model for Positron Emission Tomography
Vardi, Y., Shepp, L. A., & Kaufman, L. (1985) · Journal of the American Statistical Association · doi:10.1080/01621459.1985.10477119 · Cited by 863
Benefit of Time-of-Flight in PET: Experimental and Clinical Results
Karp, J. S., Surti, S., Daube-Witherspoon, M. E., & Muehllehner, G. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.044834 · Cited by 584
Volumetric transformation of brain anatomy
Christensen, G. E., Joshi, S. C., & Miller, M. I. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.650882 · Cited by 438
Noise and Edge Artifacts in Maximum-Likelihood Reconstructions for Emission Tomography
Snyder, D. L., Miller, M. I., Thomas, L. J., & Politte, D. G. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307831 · Cited by 421
Self-citationTime of flight in PET revisited
Moses, W. W. (2003) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2003.817319 · Cited by 336
Focus on time-of-flight PET: the benefits of improved time resolution
Conti, M. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1711-y · Cited by 335
Update on time-of-flight PET imaging
Surti, S. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.114.145029 · Cited by 303
The Use of Sieves to Stabilize Images Produced with the EM Algorithm for Emission Tomography
Snyder, D. L., & Miller, M. I. (1985) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1985.4334521 · Cited by 278
Self-citationState of the art and challenges of time-of-flight PET
Conti, M. (2009) · Physica Medica · doi:10.1016/j.ejmp.2008.10.001 · Cited by 274
Roadmap toward the 10 ps time-of-flight PET challenge
Lecoq, P., Morel, C., Prior, J. O., Visvikis, D., Gundacker, S., Auffray, E., Križan, P., Turtos, R. M., Thers, D., Charbon, E., et al. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab9500 · Cited by 258
Stopping Rule for the MLE Algorithm Based on Statistical Hypothesis Testing
Veklerov, E., & Llacer, J. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307849 · Cited by 254
Lessons Learned During the Conduct of Clinical Studies in The Dental PBRN
Gilbert, G. H., Richman, J. S., Gordan, V. V., Rindal, D. B., Fellows, J. L., Benjamin, P. L., Wallace‐Dawson, M., Williams, O. D., & for The DPBRN Collaborative Group (2011) · Journal of Dental Education · doi:10.1002/j.0022-0337.2011.75.4.tb05069.x · Cited by 59
Metadata
- Authors
- Snyder, D. L., Thomas, L. J., & Ter-Pogossian, M. M.
- Venue
- IEEE Transactions on Nuclear Science
- Published
- 1981-06
- Volume
- 28
- Issue
- 3
- Pages
- 3575-3583
- ISSN
- 0018-9499 (ISSN-L)
- OpenAlex
- W2097704405
- Cited by
- 217
- References
- 0
- FWCI
- 8.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.