The DOI matches its Crossref record; 46 of the 48 references it cites were found in a registry or an index.
A review of portable FES-based neural orthoses for the correction of drop foot
Abstract
This paper reviews the technological developments in neural orthoses for the correction of upper motor neurone drop foot since 1961, when the technique was first proposed by Liberson and his co-workers. Drop foot stimulator (DFS) developments are reviewed starting with hard-wired single-channel and multichannel surface functional electrical stimulation (FES) systems, followed by implanted drop foot stimulators, and then continuing with microprocessor-based surface and implanted drop foot stimulators. The review examines the role of artificial and "natural" sensors as replacements for the foot-switch as the primary control sensor in drop foot stimulators. DFS systems incorporating real-time control of FES and completely implanted DFS systems finish the review.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These peaks were not as well defined compared to the CVs of activated iridium oxide in et al [1].”
From Flexible Nerve Stimulation Electrode With Iridium Oxide Sputtered on Liquid Crystal Polymer (2009) · cites this paper as [1]
In the citing paper
“Similar multiple peaks had been reported by Cogan et al. [1] and Slavcheva et al. [2].”
From Flexible Nerve Stimulation Electrode With Iridium Oxide Sputtered on Liquid Crystal Polymer (2009) · cites this paper as [1]
In the citing paper
“However, these peaks indicated an active Ir(IV) + e− ⇋ Ir(III) charge transfer mechanism.”
From Flexible Nerve Stimulation Electrode With Iridium Oxide Sputtered on Liquid Crystal Polymer (2009) · cites this paper as [1]
In the citing paper
“The charge storage capacity of the iridium oxide electrodes here was observed to be larger than the charge storage capacity obtained with activated iridium oxide films reported by Agnew et al [4] and sputtered iridium oxide films reported by Cogan et al. [1]”
From Flexible Nerve Stimulation Electrode With Iridium Oxide Sputtered on Liquid Crystal Polymer (2009) · cites this paper as [1]
In the citing paper
“The morphology and structure of the iridium oxide on the LCP substrate electrodes were markedly different compared to the cauliflower morphology reported by Cogan et al [1]and Slavcheva et al [2].”
From Flexible Nerve Stimulation Electrode With Iridium Oxide Sputtered on Liquid Crystal Polymer (2009) · cites this paper as [1]
In the citing paper
“Impedance testing of the sputtered iridium oxide films also revealed Bode plots with slightly higher impedances compared the sputtered iridium oxide films reported by Cogan et al. [1] and Slavcheva et al [2], but lower compared to electrodeposited and activated iridium oxide films [3].”
From Flexible Nerve Stimulation Electrode With Iridium Oxide Sputtered on Liquid Crystal Polymer (2009) · cites this paper as [1]
Citations
Cites
Gait Analysis: Normal and Pathological Function
(1992) · JAMA · doi:10.1001/jama.1992.03490220101046 · Cited by 3,888
Perry, J., Slac, K., & Davids, J. R. (1992) · Journal of Pediatric Orthopaedics · doi:10.1097/01241398-199211000-00023 · Cited by 1,157
Wt, L., Holmquest, H. J., Scot, D., & Dow, M. (1961) · PubMed · Cited by 898
Automatic stance-swing phase detection from accelerometer data for peroneal nerve stimulation
Willemsen, A., Bloemhof, F., & Boom, H. B. K. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.64463 · Cited by 170
Cutaneous whole nerve recordings used for correction of footdrop in hemiplegic man
Haugland, M. K., & Sinkjaer, T. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481970 · Cited by 168
Application of tilt sensors in functional electrical stimulation
Dai, R., Stein, R. B., Andrews, B. J., James, K. B., & Wieler, M. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.506403 · Cited by 167
Waters, R. L., McNeal, D. R., Faloon, W., & Clifford, B. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567050-00016 · Cited by 156 · cited 1×
“A follow-up study was also carried out ten years after the implant to assess the long-term performance of the implant [63].”
BackgroundExperimental correction of footdrop by electrical stimulation of the peroneal nerve
Waters, R. L., McNeal, D. R., & Perry, J. (1975) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-197557080-00002 · Cited by 152
Sensors for Use with Functional Neuromuscular Stimulation
Crago, P. E., Chizeck, H. J., Neuman, M. R., & Hambrecht, F. T. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325808 · Cited by 142
Multicenter evaluation of electrical stimulation systems for walking
Wieler, M., Stein, R. B., Ladouceur, M., Whittaker, M., Smith, A. W., Naaman, S. C., Barbeau, H., Bugaresti, J., & Aimone, E. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90188-0 · Cited by 133
Research works printed but not linked: 27
- Acimovic, A comparative study of the functionality of the second generation of peroneal stimulators, 621
- Bogataj, Gait pattern behavior of hemiplegic patients under the influence of a six-channel microprocessor stimulator in a real environment, 529
- Bowman, Effects of stimulus pulse duration on comfort during controlled motor contractions, 429
- Burridge, Clinical results of a preliminary investigation into the use of two channel stimulation to improve the quality of walking of patients with established hemiplegia, 8
- Creasey, Clinical neural prostheses beyond 2000, 517
- Dimitrijevic, 1968, Electronic control of paralyzed extremities, Bio-med. Eng., 8
- Ewins, The Compustim 10b electrical stimulator, 6
- Hourigan, 1999, Joint angle and acceleration analysis using integrated accelerometers, J. Bone Joint Surg. [BR], 81-B, 88
- Jeglic, Electrical stimulation of skeletal muscle by directly powered implanted R.F. receivers, 42
- Jeglic, Implantable muscle/nerve stimulator as part of an electronic brace, 593
- Karsznia, 1990, Why patients use or reject a peroneal muscle stimulator?, 251
- Kelih, 1988, Dual channel implantable stimulator, 127
- Kralj, 1971, Improvement in locomotion in hemiplegic patients with multichannel electrical stimulation, 45
- Leane, 1998, The incidence of drop foot following stroke in the St. Camillus’ Hospital catchment area within the Mid-Western Health Board, Ir. J. Med. Sc., 167, 275
- Lyons, The University of Limerick Drop Foot Stimulator, 68
- Lyons, Evaluation of a drop foot stimulator FES intensity envelope matched to tibialis anterior muscle activity during walking, 448
- McNeal, The effect of peripheral nerve implanted electrical stimulation on motor control in stroke patients
- Mourselas, Correction of drop foot using a fuzzy logic controlled miniature stimulator, 456
- Pedersen, 1986, Videnskab og Praksis—Original Meddelelse—Klinisk erfaring med en ny dropfodstimulator—Clinical experience with new peroneal stimulator, Ugeskrift for Laeger, 148, 1272
- Popovic, Programmable and portable electrical stimulator for transcutaneous FES applications—Complex motion, 238
- Prochazka, 1983, Electrical stimulation of paretic leg muscles in man, allowing feedback controlled movements to be generated from the wrist, J. Physiol., 343, 20P
- Schuck, 1973, Developing clinical devices for hemiplegic stroke patients, 535
- Sweeney, 1999, Fuzzy gait event detection in a Finite State Controlled FES Drop Foot Correction System, J. Bone Joint Surg. [BR], 81-B, 93
- Symons, Trigger switches for implantable gait stimulation, 319
- Taylor, Correction of bi-lateral dropped foot using the Odstock 2 Channel Stimulator (O2CHS)
- Taylor, 2000, IMPULSE Questionnaire, Salisbury FES Newslett., 10
- Vodovnik, Electronic walking aids for patients with peroneal palsy, 58
Cited by
Sorted by citations
Functional Electrical Stimulation for Neuromuscular Applications
Peckham, P. H., & Knutson, J. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140103 · Cited by 805
Methods for gait event detection and analysis in ambulatory systems
Rüterbories, J., Spaich, E. G., Larsen, B. T., & Andersen, O. K. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.03.007 · Cited by 350
Mrachacz‐Kersting, N., Jiang, N., Stevenson, A. J. T., Niazi, I. K., Kostić, V., Pavlovic, A. M., Radovanovic, S. M., Djuric-Jovicic, M. D., Agosta, F., Dremstrup, K., et al. (2015) · Journal of Neurophysiology · doi:10.1152/jn.00918.2015 · Cited by 277
Kottink, A. I. R., Oostendorp, L. J. M., Buurke, J. H., Nene, A. V., Hermens, H. J., & IJzerman, M. J. (2004) · Artificial Organs · doi:10.1111/j.1525-1594.2004.07310.x · Cited by 248
Long-term usability and bio-integration of polyimide-based intra-neural stimulating electrodes
Wurth, S., Capogrosso, M., Raspopovic, S., Gandar, J., Federici, G., Kinany, N., Cutrone, A., Piersigilli, A., Pavlova, N., Guiet, R., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.01.014 · Cited by 176
Metadata
- Authors
- Lyons, G. M., Sinkjaer, T., Burridge, J. H., & Wilcox, D. J.
- Affiliations
- University of Limerick (IE)
- University of Southampton (GB)
- Ollscoil na Gaillimhe – University of Galway (IE)
- ORCID
- Burridge, J.H.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2002-12
- Volume
- 10
- Issue
- 4
- Pages
- 260-279
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2165067332
- Cited by
- 277
- References
- 48
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 8 · 2023: 8 · 2022: 10 · 2021: 10 · 2020: 14 · 2019: 9 · 2018: 10 · 2017: 20 · 2016: 17 · 2015: 20 · 2014: 16 · 2013: 19 · 2012: 13
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- VBN Forskningsportal (Aalborg Universitet) (submittedVersion)
- Topics
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- foot drop, functional electrical stimulation, upper motor neuron lesion, surface stimulation
- MeSH terms
- Electrodes, Implanted, Electric Stimulation Therapy, Equipment Design, Foot, Humans, Microelectrodes, Miniaturization, Orthotic Devices, Peroneal Nerve, Therapy, Computer-Assisted, Transducers, Muscle, Skeletal, Gait Disorders, Neurologic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review