ERPs evoked by different matrix sizes: implications for a brain computer interface (BCI) system
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
A brain-computer interface (BCI) system may allow a user to communicate by selecting one of many options. These options may be presented in a matrix. Larger matrices allow a larger vocabulary, but require more time for each selection. In this study, subjects were asked to perform a target detection task using matrices appropriate for a BCI. The study sought to explore the relationship between matrix size and EEG measures, target detection accuracy, and user preferences. Results indicated that larger matrices evoked a larger P300 amplitude, and that matrix size did not significantly affect performance or preferences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 2×
“One class of evoked BCIs explored in the literature has been called a P300 BCI [1]–[3], [5].”
BackgroundEvoked-potential correlates of stimulus uncertainty
Sutton, S., Braren, M., Zubin, J., & John, E. R. (1965) · Science · doi:10.1126/science.150.3700.1187 · Cited by 3,061 · cited 1×
“Target flashes produced a robust P300 response, while nontarget flashes did not, as expected from prior work on the P300 [8], [14], for review see [11].”
ResultDynamic Brain Sources of Visual Evoked Responses
Makeig, S., Westerfield, M., Jung, T.-P., Enghoff, S., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2002) · Science · doi:10.1126/science.1066168 · Cited by 1,630 · cited 1×
“For example, recent work [6], [7] showed that ICA can separate components which vary with attention from those which do not.”
BackgroundThe mental prosthesis: assessing the speed of a P300-based brain-computer interface
Donchin, E., Spencer, K. M., & Wijesinghe, R. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847808 · Cited by 1,222 · cited 2×
“One class of evoked BCIs explored in the literature has been called a P300 BCI [1]–[3], [5].”
BackgroundJohnson, R. (1986) · Psychophysiology · doi:10.1111/j.1469-8986.1986.tb00649.x · Cited by 960 · cited 1×
“Target flashes produced a robust P300 response, while nontarget flashes did not, as expected from prior work on the P300 [8], [14], for review see [11].”
ResultThe P300 component of the event-related brain potential as an index of information processing
Duncan-Johnson, C. C., & Donchin, E. (1982) · Biological Psychology · doi:10.1016/0301-0511(82)90016-3 · Cited by 475 · cited 4×
“There was also a significant interaction between size and site, with larger matrices producing larger posterior P300s (see Table II; p = 0:039), and a highly significant interaction between attention and site; consistent with prior work, the attend versus ignore difference was larger over posterior sites.”
BackgroundInfluentialPolich, J. (1987) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(87)90052-9 · Cited by 420 · cited 1×
“17, and such improbable events had been shown to produce robust P300s [4], [9], [10], [12].”
BackgroundThe brain response interface: communication through visually-induced electrical brain responses
Sutter, E. E. (1992) · Journal of Microcomputer Applications · doi:10.1016/0745-7138(92)90045-7 · Cited by 417
Makeig, S., Westerfield, M., Jung, T.-P., Covington, J., Townsend, J., Sejnowski, T. J., & Courchesne, E. (1999) · The Journal of Neuroscience · doi:10.1523/jneurosci.19-07-02665.1999 · Cited by 385 · cited 1×
“For example, recent work [6], [7] showed that ICA can separate components which vary with attention from those which do not.”
Background
Cited by
Bashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
A comparison of classification techniques for the P300 Speller
Krusienski, D. J., Sellers, E. W., Cabestaing, F., Bayoudh, S., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/007 · Cited by 762
A P300-based brain–computer interface: Initial tests by ALS patients
Sellers, E. W., & Donchin, E. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.06.027 · Cited by 711
EMG and EOG artifacts in brain computer interface systems: A survey
Fatourechi, M., Bashashati, A., Ward, R. K., & Birch, G. E. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.10.019 · Cited by 638
Townsend, G., LaPallo, B. K., Boulay, C. B., Krusienski, D. J., Frye, G. E., Hauser, C. K., Schwartz, N. E., Vaughan, T. M., Wolpaw, J. R., & Sellers, E. W. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.030 · Cited by 570
“This relationship is found in standard oddball experiments (e.g., Duncan-Johnson and Donchin, 1977) and also in BCI applications (Allison and Pineda, 2003; Sellers et al., 2006).”
MethodResultSellers, E. W., Krusienski, D. J., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Biological Psychology · doi:10.1016/j.biopsycho.2006.04.007 · Cited by 501
Riemannian geometry for EEG-based brain-computer interfaces; a primer and a review
Congedo, M., Barachant, A., & Bhatia, R. (2017) · Brain-Computer Interfaces · doi:10.1080/2326263x.2017.1297192 · Cited by 456
Brain–computer interface systems: progress and prospects
Allison, B. Z., Wolpaw, E. W., & Wolpaw, J. R. (2007) · Expert Review of Medical Devices · doi:10.1586/17434440.4.4.463 · Cited by 420
Self-citationAn improved P300-based brain-computer interface
Serby, H., Yom-Tov, E., & Inbar, G. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.841878 · Cited by 403
P300 brain computer interface: current challenges and emerging trends
Fazel-Rezai, R., Allison, B. Z., Guger, C., Sellers, E. W., Kleih, S. C., & Kübler, A. (2012) · Frontiers in Neuroengineering · doi:10.3389/fneng.2012.00014 · Cited by 359
Self-citationTowards an independent brain–computer interface using steady state visual evoked potentials
Allison, B. Z., McFarland, D. J., Schalk, G., Zheng, S. D., Jackson, M. M., & Wolpaw, J. R. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.09.121 · Cited by 327
Self-citationFlashing characters with famous faces improves ERP-based brain–computer interface performance
Kaufmann, T., Schulz, S. M., Grünzinger, C., & Kübler, A. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/5/056016 · Cited by 300
A Comprehensive Survey of Brain Interface Technology Designs
Mason, S. G., Bashashati, A., Fatourechi, M., Navarro, K. F., & Birch, G. E. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9170-0 · Cited by 299
Does the ‘P300’ speller depend on eye gaze?
Brunner, P., Joshi, S., Briskin, S., Wolpaw, J. R., Bischof, H., & Schalk, G. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/5/056013 · Cited by 291
Steady-state somatosensory evoked potentials: suitable brain signals for brain-computer interfaces?
Muller-Putz, G. R., Scherer, R., Neuper, C., & Pfurtscheller, G. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.863842 · Cited by 288
A tactile P300 brain-computer interface
Brouwer (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00019 · Cited by 278
Visual modifications on the P300 speller BCI paradigm
Salvaris, M., & Sepulveda, F. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046011 · Cited by 197
Lulé, D., Noirhomme, Q., Kleih, S. C., Chatelle, C., Halder, S., Demertzi, A., Bruno, M.-A., Gosseries, O., Vanhaudenhuyse, A., Schnakers, C., et al. (2013) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.04.030 · Cited by 189
“Four healthy controls presented an observable negative deflection which is also often seen as a reaction to P3-BCI stimulation (Allison and Pineda, 2003; Bianchi et al., 2010; Kaufmann et al., 2011).”
InfluentialToward a high-throughput auditory P300-based brain–computer interface
Klobassa, D. S., Vaughan, T. M., Brunner, P., Schwartz, N. E., Wolpaw, J. R., Neuper, C., & Sellers, E. W. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.04.019 · Cited by 165
“This visual P300 speller paradigm is well established and provides reasonable control for a BCI (Donchin et al., 2000; Serby et al., 2005; Allison and Pineda, 2003; Krusienski et al., 2006; Sellers et al., 2006; Hoffmann et al., 2008).”
MethodHigh performance p300 speller for brain-computer interface
Guan, C., Thulasidas, M., & Wu, J. (2005) · IEEE International Workshop on Biomedical Circuits and Systems, 2004. · doi:10.1109/biocas.2004.1454155 · Cited by 165
“Brendan etc [11] studied the relationship between accuracy and various size of speller matrix.”
An adaptive P300-based control system
Jin, J., Allison, B. Z., Sellers, E. W., Brunner, C., Horki, P., Wang, X., & Neuper, C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036006 · Cited by 158
“P300 BCIs have been validated with disabled users, with visual, auditory and tactile stimuli (Allison and Pineda 2003, Hoffmann et al 2005, 2008, Sellers et al 2006, 2010, Allison and Pineda 2006, Sellers and Donchin 2006, Furdea et al 2009, K¨ubler et al 2009, Guger et al 2009, Townsend et al…”
BackgroundMethodResultInfluentialSelf-citationAricò, P., Borghini, G., Di Flumeri, G., Colosimo, A., Pozzi, S., & Babiloni, F. (2016) · Progress in Brain Research · doi:10.1016/bs.pbr.2016.04.021 · Cited by 145
A covert attention P300-based brain–computer interface: Geospell
Aloise, F., Aricò, P., Schettini, F., Riccio, A., Salinari, S., Mattia, D., Babiloni, F., & Cincotti, F. (2012) · Ergonomics · doi:10.1080/00140139.2012.661084 · Cited by 88
A comparison study of two P300 speller paradigms for brain–computer interface
Pan, J., Li, Y., Gu, Z., & Yu, Z. (2013) · Cognitive Neurodynamics · doi:10.1007/s11571-013-9253-1 · Cited by 46
“Usually, ear lobe or mastoid (i.e. bony outgrowth behind the ear) is used as reference channel (Allison and Pineda 2003; Allison and Pineda 2006; McFarland et al. 2011; Fazel-Rezai and Abhari 2009; Townsend et al. 2010; Guger et al. 2009; Talebi et al. 2012).”
BackgroundMethodInfluential
Metadata
- Authors
- Allison, B. Z., & Pineda, J. A.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2003-06
- Volume
- 11
- Issue
- 2
- Pages
- 110-113
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2160722169
- Cited by
- 225
- References
- 16
- FWCI
- 2.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.