CoChat

Amplitude- and Frequency-Dependent Changes in Neuronal Regularity Parallel Changes in Tremor With Thalamic Deep Brain Stimulation

Kuncel, Alexis M., Cooper, Scott E., Wolgamuth, Barbara R., Grill, Warren M. · 2007 · IEEE Transactions on Neural Systems and Rehabilitation Engineering
Cited by 73

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

The mechanisms by which deep brain stimulation (DBS) alleviates tremor remain unclear, but successful treatment can be achieved with properly selected frequency and amplitude. The clinical tremor response to thalamic DBS for essential tremor is dependent on the stimulation frequency and amplitude, and for high frequencies (> or = 90 Hz), increasing amplitude suppressed tremor, whereas for low frequencies (< 60 Hz), increasing amplitude aggravated tremor. We studied the effects of stimulation frequency and amplitude on the output of a population of intrinsically active model neurons to test the hypothesis that regularization of neuronal firing patterns is responsible for the clinical effectiveness of DBS. The firing patterns of model thalamocortical neurons were dependent on stimulation frequency and amplitude in a manner similar to the clinical tremor response. Above a critical frequency, increasing amplitude reduced the coefficient of variation (CV) of the neuronal firing pattern, whereas for low frequencies, increasing the amplitude increased the CV of neuronal activity. The correlation between the changes in tremor and the changes in the CV of neuronal firing supports the hypothesis that regularization of neuronal firing pattern during DBS is one of the mechanisms underlying the suppression of tremor.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2007.897004

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 73

Metadata

Authors
Kuncel, A. M., Cooper, S. E., Wolgamuth, B. R., & Grill, W. M.
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2007-06
Volume
15
Issue
2
Pages
190-197
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2162816158
Cited by
73
References
5
FWCI
2.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Amplitude- and Frequency-Dependent Changes in Neuronal Regularity Parallel Changes in Tremor With Thalamic Deep Brain Stimulation. https://app.cochat.ai/papers/10.1109/tnsre.2007.897004
The paper
Kuncel, A. M., Cooper, S. E., Wolgamuth, B. R., & Grill, W. M. (2007). Amplitude- and Frequency-Dependent Changes in Neuronal Regularity Parallel Changes in Tremor With Thalamic Deep Brain Stimulation. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2007.897004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.