Neural Prostheses: Electrophysiological and Histological Evaluation of Central Nervous System Alterations Due to Long-Term Implants of Sieve Electrodes to Peripheral Nerves in Cats

Panetsos, Fivos, Avendano, Carlos, Negredo, Pilar, Castro, Jorge, Bonacasa, Vanessa · 2008 · IEEE Transactions on Neural Systems and Rehabilitation Engineering
Cited by 20

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

We have investigated the alterations that the long-term implant of sieve electrodes to the peripheral nerves could evoke in the central nervous system by studying the neural activity at various levels of the somatosensory system [the implanted nerves, the dorsal column nuclei (DCN), and the primary somatosensory cortex (SI)] up to 30 months after implantation of the electrode in the distal median nerve in adult cats. This long survival period, which could correspond to 15 years within a human lifespan, enabled us to confirm the biocompatibility of the electrode. We also performed histological and molecular studies on sections of the spinal cord, DCN, and SI and electrophysiological recordings on of DCN and SI. Although in the "implanted" regions (ipsilateral nerve, ipsilateral DCN, and contralateral SI) there was apparently a good recovery of a number of molecular markers, mostly related to local metabolism and neurotransmission in central relay structures, the expression of calcium-binding proteins in the cortex, which identifies inhibitory interneurons, remained clearly abnormal, although they were never as altered as in case of irreversible, chronic denervations. Also, prominent anatomical disorganization was detected in the normal spatial arrangement of neural clusters within the DCN. With respect to the electrical activity the "implanted side" showed minor changes in response latency, intensity, and somatotopy, compared to control recordings. These findings show that central sensory-processing structures achieve fair, but not complete, levels of structural and functional reorganization following chronic intraneural implants of sieve electrodes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2008.923707

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 20

Metadata

Authors
Panetsos, F., Avendano, C., Negredo, P., Castro, J., & Bonacasa, V.
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2008-06
Volume
16
Issue
3
Pages
223-232
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2102834260
Cited by
20
References
7
FWCI
0.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Neural Prostheses: Electrophysiological and Histological Evaluation of Central Nervous System Alterations Due to Long-Term Implants of Sieve Electrodes to Peripheral Nerves in Cats. https://app.cochat.ai/papers/10.1109/tnsre.2008.923707
The paper
Panetsos, F., Avendano, C., Negredo, P., Castro, J., & Bonacasa, V. (2008). Neural Prostheses: Electrophysiological and Histological Evaluation of Central Nervous System Alterations Due to Long-Term Implants of Sieve Electrodes to Peripheral Nerves in Cats. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2008.923707

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.