Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 38 of the 42 references it cites were found in a registry or an index.

Stimulation selectivity of the “thin-film longitudinal intrafascicular electrode”(tfLIFE) and the “transverse intrafascicular multi-channel electrode”(TIME) in the large nerve animal model

Kundu, Aritra, Harreby, Kristian Rauhe, Yoshida, Ken, Boretius, Tim, Stieglitz, Thomas, Jensen, Winnie · 2014 · IEEE Transactions on Neural Systems and Rehabilitation Engineering

Abstract

Neural prostheses are limited by the availability of peripheral neural electrodes to record the user's intention or provide sensory feedback through functional electrical stimulation. Our objective was to compare the ability of the novel “transverse intrafascicular multi-channel electrode” (TIME) and an earlier generation “thin-film longitudinal intrafascicular electrode” (tfLIFE) to selectively stimulate nerve fascicles and activate forelimb muscles in pigs. TIME was designed to access a larger subpopulation of fascicles than tfLIFE and should therefore be able to selectively activate a larger number of muscles. Electrodes were implanted in the median nerve, and sequential electric stimulation was applied to individual contacts. The compound muscle action potentials of seven muscles were recorded to quantify muscle recruitment. As expected, TIME was able to recruit more muscles with higher selectivity than tfLIFE (significant difference when comparing the performance of an entire electrode); a similar activation current was used (no significant difference). Histological analysis revealed that electrodes were located between fascicles, which influenced the selectivity and activation current level. In conclusion, TIME is a viable neural interface for selective activation of multiple fascicles in human-sized nerves that may assist to pave the way for future neuroprosthesis applications.

Overview

Integrity signals

Registry

Crossref · 10.1109/tnsre.2013.2267936

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 42 references

Research works printed but not linked: 9

  1. swindle, 1998, Comparative anatomy and physiology of the pig, Scand J Lab Animal Sci, 25, 1
  2. pond, 1978, The Biology of the Pig, 13
  3. kundu, 2012, Comparison of median and ulnar nerve mrorphology of danish landrace pigs and g�ttingen mini pigs, 10th Annu Conf IFESS
  4. bridges, 2010, Revolutionizing prosthetics 2009: Dexterous control of an upper-limb neuroprosthesis, Johns Hopkins APL Tech Dig, 28, 210
  5. dario, 2002, CYBERHAND?A consortium project for enhanced control of powered artificial hands based on direct neural interfaces, 33rd Neural Prosthesis Workshop
  6. robblee, 1990, Electrochemical guidelines for selection of protocols and electrode materials for neural stimulation, Neural Prostheses Fundamental Studies, 25
  7. kundu, 0, Assessment of the biocompatibility of the transverse intrafascicular multi-channel electrode (TIME) following sub-chronic implantation in the median nerve of the G�ttingen mini-pig, J Neural Eng
  8. harreby, 0, Evaluation of the chronic stimulation performance of the Transverse, Intrafascicular, Multi-channel Electrode (TIME) in the G�ttingen mini-pig, IEEE Trans Neural Syst Rehabil Eng
  9. kundu, 2010, Dependence of implantation angle of the transverse, intrafascicular electrode (TIME) on selective activation of pig forelimb muscles, Artif Organs, 34, 43a

Cited by

See all 83

Metadata

Authors
Kundu, A., Harreby, K. R., Yoshida, K., Boretius, T., Stieglitz, T., & Jensen, W.
Affiliations
  • Aalborg University (DK)
  • University of Freiburg (DE)
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2014-03
Volume
22
Issue
2
Pages
400-410
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W1971319333
Cited by
83
References
42
Citations by year
2026: 3 · 2025: 5 · 2024: 5 · 2023: 4 · 2022: 8 · 2021: 5 · 2020: 10 · 2019: 10 · 2018: 7 · 2017: 11 · 2016: 7 · 2015: 3 · 2014: 4
FWCI
2.28
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • VBN Forskningsportal (Aalborg Universitet) (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
Keywords
intrafascicular electrodes, functional electrical stimulation, median nerve, compound muscle action potential, muscle recruitment, neural interfaces, neural prostheses, porcine model
MeSH terms
Action Potentials, Algorithms, Analysis of Variance, Animals, Data Interpretation, Statistical, Electric Stimulation, Electrodes, Implanted, Equipment Design, Female, Forelimb, Peripheral Nerves, Recruitment, Neurophysiological, Swine, Muscle, Skeletal, Neural Prostheses

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stimulation selectivity of the “thin-film longitudinal intrafascicular electrode”(tfLIFE) and the “transverse intrafascicular multi-channel electrode”(TIME) in the large nerve animal model. https://app.cochat.ai/papers/10.1109/tnsre.2013.2267936
The paper
Kundu, A., Harreby, K. R., Yoshida, K., Boretius, T., Stieglitz, T., & Jensen, W. (2014). Stimulation selectivity of the “thin-film longitudinal intrafascicular electrode”(tfLIFE) and the “transverse intrafascicular multi-channel electrode”(TIME) in the large nerve animal model. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2013.2267936

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.