Humans Can Integrate Force Feedback to Toes in Their Sensorimotor Control of a Robotic Hand
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Tactile sensory feedback is essential for dexterous object manipulation. Users of hand myoelectric prostheses without tactile feedback must depend essentially on vision to control their device. Indeed, improved tactile feedback is one of their main priorities. Previous research has provided evidence that conveying tactile feedback can improve prostheses control, although additional effort is required to solve problems related to pattern recognition learning, unpleasant sensations, sensory adaptation, and low spatiotemporal resolution. Still, these studies have mainly focused on providing stimulation to hairy skin regions close to the amputation site, i.e., usually to the upper arm. Here, we explored the possibility to provide tactile feedback to the glabrous skin of toes, which have mechanical and neurophysiological properties similar to the fingertips. We explored this paradigm in a grasp-and-lift task, in which healthy participants controlled two opposing digits of a robotic hand by changing the spacing of their index finger and thumb. The normal forces applied by the robotic fingertips to a test object were fed back to the right big and second toe. We show that within a few lifting trials, all the participants incorporated the force feedback received by the foot in their sensorimotor control of the robotic hand.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A multimodal cortical network for the detection of changes in the sensory environment
Downar, J., Crawley, A. P., Mikulis, D. J., & Davis, K. D. (2000) · Nature Neuroscience · doi:10.1038/72991 · Cited by 947 · cited 1×
“This is known to engage specific cortical networks [ 29 ], and certain parts of this network are particularly activated when the multimodal sensory information is relevant to a task [30], [31].”
BackgroundJohansson, R. S., & Westling, G. (1987) · Experimental Brain Research · doi:10.1007/bf00236210 · Cited by 865 · cited 1×
“In humans, the mechanoreceptors of the glabrous skin provide information about both force vectors and slip events [27], [ 28 ].”
BackgroundSelf-citationElectrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827
Integration of Proprioceptive and Visual Position-Information: An Experimentally Supported Model
van Beers, R. J., Sittig, A. C., & Gon, J. J. D. V. D. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.81.3.1355 · Cited by 742 · cited 1×
“One important factor concerns how signals in conflicting sensory sources are weighted, where the precision of each source with respect to the task can play a decisive role [ 33 ], [34].”
BackgroundDirect neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573
Dhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354 · cited 1×
“Direct intraneural stimulation might appear as a promising feedback method for the long term future [ 7 ], [8].”
MethodDesign and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands
Pylatiuk, C., Kargov, A., & Schulz, S. (2006) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-200604000-00007 · Cited by 156 · cited 1×
“Consequently there seems to be no need to limit the time during which the feedback stimulationisdelivered,asisrequiredwithvibrotactileandelectrotactile feedback devices [9], [ 14 ].”
BackgroundPatterson, P. E., & Katz, J. A. (1992) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.1992.01.0001 · Cited by 147
Cited by
Sensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Haptic wearables as sensory replacement, sensory augmentation and trainer – a review
Shull, P. B., & Damian, D. D. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0055-z · Cited by 245
“While many skin sites have been explored for tactile stimulation [49–52], fingertips are an attractive location due to the high density of the mechanoreceptors and the congruency of grasp sensation with the lost hand.”
BackgroundThe role of feed-forward and feedback processes for closed-loop prosthesis control
Saunders, I., & Vijayakumar, S. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-60 · Cited by 193
“In a similar way, prosthesis fingertip forces have been transferred to the stump [13] or even the toes of amputees [14] to create appropriate and useful sensations.”
BackgroundTan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., & Tyler, D. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/2/026002 · Cited by 175
Metadata
- Authors
- Panarese, A., Edin, B. B., Vecchi, F., Carrozza, M. C., & Johansson, R. S.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2009-12
- Volume
- 17
- Issue
- 6
- Pages
- 560-567
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2099005287
- Cited by
- 47
- References
- 8
- FWCI
- 1.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.