The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
The role of feed-forward and feedback processes for closed-loop prosthesis control
Open accessAbstract
BACKGROUND: It is widely believed that both feed-forward and feed-back mechanisms are required for successful object manipulation. Open-loop upper-limb prosthesis wearers receive no tactile feedback, which may be the cause of their limited dexterity and compromised grip force control. In this paper we ask whether observed prosthesis control impairments are due to lack of feedback or due to inadequate feed-forward control. METHODS: Healthy subjects were fitted with a closed-loop robotic hand and instructed to grasp and lift objects of different weights as we recorded trajectories and force profiles. We conducted three experiments under different feed-forward and feed-back configurations to elucidate the role of tactile feedback (i) in ideal conditions, (ii) under sensory deprivation, and (iii) under feed-forward uncertainty. RESULTS: (i) We found that subjects formed economical grasps in ideal conditions. (ii) To our surprise, this ability was preserved even when visual and tactile feedback were removed. (iii) When we introduced uncertainty into the hand controller performance degraded significantly in the absence of either visual or tactile feedback. Greatest performance was achieved when both sources of feedback were present. CONCLUSIONS: We have introduced a novel method to understand the cognitive processes underlying grasping and lifting. We have shown quantitatively that tactile feedback can significantly improve performance in the presence of feed-forward uncertainty. However, our results indicate that feed-forward and feed-back mechanisms serve complementary roles, suggesting that to improve on the state-of-the-art in prosthetic hands we must develop prostheses that empower users to correct for the inevitable uncertainty in their feed-forward control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Factors influencing the force control during precision grip
Westling, G., & Johansson, R. S. (1984) · Experimental Brain Research · doi:10.1007/bf00238156 · Cited by 1,027
Kuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583
Computational principles of sensorimotor control that minimize uncertainty and variability
Bays, P. M., & Wolpert, D. M. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.120121 · Cited by 359
Robotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees
Marasco, P. D., Kim, K., Colgate, J. E., Peshkin, M. A., & Kuiken, T. A. (2011) · Brain · doi:10.1093/brain/awq361 · Cited by 335 · cited 2×
“Vivid sensations of embodiment and prosthesis ownership can only be achieved through physiologically appropriate cutaneous feedback [15].”
BackgroundDecoding a New Neural–Machine Interface for Control of Artificial Limbs
Zhou, P., Lowery, M. M., Englehart, K. B., Huang, H., Li, G., Hargrove, L., Dewald, J. P. A., & Kuiken, T. A. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00178.2007 · Cited by 215 · cited 1×
“Nevertheless, state-of-the-art upper limb prostheses are still open-loop devices with limited degrees of control, described as “clumsy” [9] and requiring considerable mental effort [10].”
BackgroundPatterson, P. E., & Katz, J. A. (1992) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.1992.01.0001 · Cited by 147
Cholewiak, R. W., & Collins, A. A. (2000) · Perception & Psychophysics · doi:10.3758/bf03212124 · Cited by 116
Research works printed but not linked: 16
- 10.1007/BF02440956 · DOI
- 10.1007/BF02442481 · DOI
- 10.1109/10.68206 · DOI
- 10.1016/j.brainresbull.2008.01.017 · DOI
- 10.1007/s00422-008-0279-0 · DOI
- 10.1109/TNSRE.2005.856072 · DOI · Paper page
- 10.1016/j.apmr.2008.05.016 · DOI
- 10.1007/s00422-006-0124-2 · DOI · Paper page
- 10.1177/1545968309338194 · DOI
- 10.1007/BF02347046 · DOI
- 10.1016/j.humov.2004.10.005 · DOI
- 10.3109/03093641003767207 · DOI
- 10.1109/TNSRE.2002.1031977 · DOI
- 10.1109/10.68204 · DOI · Paper page
- 10.1080/17470210801985235 · doi:10.1080/17470210801985235
- 10.1186/1743-0003-7-42 · DOI
Cited by
Sensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Restoration of sensory information via bionic hands
Bensmaia, S. J., Tyler, D. J., & Micera, S. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00630-8 · Cited by 257
Schiefer, M., Tan, D., Sidek, S. M., & Tyler, D. J. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/1/016001 · Cited by 255
Haptic wearables as sensory replacement, sensory augmentation and trainer – a review
Shull, P. B., & Damian, D. D. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0055-z · Cited by 245
Metadata
- Authors
- Saunders, I., & Vijayakumar, S.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2011
- Volume
- 8
- Issue
- 1
- Pages
- 60
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2115327539
- Cited by
- 193
- References
- 7
- FWCI
- 4.97
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The role of feed-forward and feedback processes for closed-loop prosthesis control. https://app.cochat.ai/papers/10.1186/1743-0003-8-60
- The paper
- Saunders, I., & Vijayakumar, S. (2011). The role of feed-forward and feedback processes for closed-loop prosthesis control. Journal of NeuroEngineering and Rehabilitation. https://doi.org/10.1186/1743-0003-8-60
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.