Stimulation Stability and Selectivity of Chronically Implanted Multicontact Nerve Cuff Electrodes in the Human Upper Extremity
Open accessAbstract
Nine spiral nerve cuff electrodes were implanted in two human subjects for up to three years with no adverse functional effects. The objective of this study was to look at the long term nerve and muscle response to stimulation through nerve cuff electrodes. The nerve conduction velocity remained within the clinically accepted range for the entire testing period. The stimulation thresholds stabilized after approximately 20 weeks. The variability in the activation over time was not different from muscle-based electrodes used in implanted functional electrical stimulation systems. Three electrodes had multiple, independent contacts to evaluate selective recruitment of muscles. A single muscle could be selectively activated from each electrode using single-contact stimulation and the selectivity was increased with the use of field steering techniques. The selectivity after three years was consistent with selectivity measured during the implant surgery. Nerve cuff electrodes are effective for chronic muscle activation and multichannel functional electrical stimulation in humans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The helical (Agnew et al., 1989) and spiral (Naples et al., 1988) type interfaces have been proven to be stable for decades in clinical applications (Fisher et al., 2009; Polasek et al., 2009).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Polasek et al., 2009
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Electrical stimulation in the form of spikes has been given to the residual stump nerve of a patient through typically implanted electrodes, and psychophysical judgments and verbal reports were gathered (Polasek et al., 2009; Schiefer et al., 2016).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Polasek et al., 2009
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“In a 3-year clinical study with two subjects, spiral cuff electrodes were shown to provide stable and selective stimulation without serious adverse reactions, after achieving stable stimulation thresholds around the 20th week [72].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [72]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zăgrean, L. (2014) · Acta Endocrinologica (Bucharest) · doi:10.4183/aeb.2014.529 · Cited by 1,922
The adaptive response of skeletal muscle to increased use
Salmons, S., & Henriksson, J. (1981) · Muscle & Nerve · doi:10.1002/mus.880040204 · Cited by 765
Katz, B., & Miledi, R. (1965) · Proceedings of the Royal Society B Biological Sciences · doi:10.1098/rspb.1965.0016 · Cited by 609
Veraart, C., Raftopoulos, C., Mortimer, J. T., Delbeke, J., Pins, D., Michaux, G., Vanlierde, A., Parrini, S., & Wanet-Defalque, M.-C. (1998) · Brain Research · doi:10.1016/s0006-8993(98)00977-9 · Cited by 418
A spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398 · cited 3×
“electrodes with up to 12 stimulation positions could selectively activate all four functions without using field steering [13].”
Self-citationSelective control of muscle activation with a multipolar nerve cuff electrode
Veraart, C., Grill, W. M., & Mortimer, J. T. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237694 · Cited by 320
The Effect of Stimulus Parameters on the Recruitment Characteristics of Direct Nerve Stimulation
Gorman, P. H., & Mortimer, J. T. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325041 · Cited by 313
Smith, B., Tang, Z., Johnson, M. W., Pourmehdi, S., Gazdik, M. M., Buckett, J. R., & Peckham, P. H. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.664202 · Cited by 270
Pattern recognition with the optic nerve visual prosthesis
Veraart, C., Wanet‐Defalque, M., Gérard, B., Vanlierde, A., & Delbeke, J. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.07305.x · Cited by 259
Cited by
Sorted by citations
Items 101–142 of 142
Zhang, J., Chou, C.-H., Hao, M., Li, Y., Yu, Y., & Lan, N. (2023) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2023.1298176 · Cited by 3
Schearer, E. M., & Wolf, D. N. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab68b3 · Cited by 3
Katic, N., Valle, G., & Raspopović, S. (2022) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_100-1 · Cited by 3
Improving Neuroprosthesis-Assisted Standing with Nerve-Based Stimulating Electrodes
Fisher, L. E. (2012) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 3
A Comparative Study of Cuff Electrode Designs: RF-Induced Heating in MRI and Therapeutic Efficiency
Xu, Y., Yang, L., Zhang, L., Wang, Z., & Chen, J. (2025) · IEEE Texas Symposium on Wireless and Microwave Circuits and Systems (WMCS) · doi:10.1109/wmcs63512.2025.11104917 · Cited by 2
Sensing and stimulation of the vagus nerve for artificial cardiac control
Ordelman, S. C. M. A. (2011) · doi:10.3990/1.9789036533096 · Cited by 2
Upper Extremity Neuroprosthetics for Spinal Cord Injury
Kilgore, K. L. (2021) · Springer eBooks · doi:10.1007/978-3-030-68545-4_5 · Cited by 1
Regnacq, L., Thota, A. K., Sanabria, A. O., McPherson, L. M., Renaud, S., Romain, O., Bornat, Y., Abbas, J. J., Jung, R., & Kölbl, F. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adc62a · Cited by 1
The Cutting Edge of Peripheral Nerve Surgery: A Look at Emerging Techniques
Garozzo, D., Llorian, E., Henriques, V. M., Sanches, G. E., Torrão, F., & Guedes, F. (2025) · Springer eBooks · doi:10.1007/978-3-031-92445-3_6 · Cited by 1
Differential Tissue‐Coupled Powering for Battery‐Free Injectable Electroceuticals
Wu, H., Mahmud, S. A. S., Halac, M., Omi, A. I., Rodas, D. S. B., Dados, J., Cheng, C., Jiang, A., Wallace, C., Singh, A., et al. (2026) · Advanced Science · doi:10.1002/advs.76915 · Cited by 1
Coste, C., Guiho, T., Ferreira, F. A., Bailly, F., Degeorge, B., Geffrier, A., Andreu, D., Teissier, J., Guiraud, D., & Fattal, C. (2026) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-025-01857-9 · Cited by 2
Li, M., Ly, C. M., Wen, J., Rustogi, P., & Meng, E. F. (2026) · Bioelectronic Medicine · doi:10.1186/s42234-025-00199-0 · Cited by 1
Influence of Selectivity Metric Choice on Motor Restoration With Neural Electrical Stimulation
Toni, L., Verardo, C., Micera, S., & Romeni, S. (2025) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner61569.2025.11588948 · Cited by 1
Maciejasz, P., Marcol, W., Paśniczek, R., Lewin‐Kowalik, J., & Hoffmann, K. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-11 · Cited by 1
Wang, R., Yu, H., & Li, Z. (2017) · Toxinology · doi:10.1007/978-981-10-2798-7_41-1 · Cited by 2
Kundu, A., Patrick, E. E., Currlin, S., Madler, R., Delgado, F., Fahmy, A., Verplancke, R., Ballini, M., Braeken, D., de Beeck, M. O., et al. (2024) · Micromachines · doi:10.3390/mi15020280 · Cited by 1
Stimulation for Return of Upper-Extremity Function
Kilgore, K. L., & Peckham, P. H. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-805353-9.00096-6 · Cited by 1
Katic, N., Valle, G., & Raspopović, S. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_100 · Cited by 1
Progress in Peripheral Neural Interfaces
Qiao, S., Mauser, K. A., & Yoshida, K. (2013) · Wiley eBooks · doi:10.1002/9781118628522.ch4 · Cited by 1
Cox, T. G. H. (2017) · Purdue e-Pubs (Purdue University System) · doi:10.7912/c2gd32 · Cited by 1
Tigra, W., Coste, C., Teissier, J., Gélis, A., Coulet, B., Divoux, J., & Guiraud, D. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/534362 · Cited by 1
Peripheral Nerve Interface, Epineural Electrode
Fisher, L. E. (2014) · Springer eBooks · doi:10.1007/978-1-4614-7320-6_210-1 · Cited by 1
Liu, Y., & Liu, J. (2012) · Frontiers of Mechanical Engineering · doi:10.1007/s11465-012-0352-1
Rewiring the Nervous System, Without Wires
Borton, D. A. (2016) · Wiley eBooks · doi:10.1002/9781119069225.ch3-2
Controlling Prostheses Using PNS Invasive Interfaces for Amputees
Carpaneto, J., Citi, L., Raspopović, S., Rigosa, J., & Micera, S. (2013) · Wiley eBooks · doi:10.1002/9781118628522.ch16
The Feasibility of an Upper Extremity Poststroke Neuroprosthesis
Makowski, N. S. (2013) · OhioLink ETD Center (Ohio Library and Information Network)
Neuroprostheses for Restoring Sensation
Tyler, D. J. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-805353-9.00103-0
Self-citationOsseointegrated Amputation Prostheses and Implanted Electrodes
Li, Y., Ortiz-Catalan, M., & Brånemark, R. (2021) · Springer eBooks · doi:10.1007/978-3-030-60746-3_6 · Cited by 1
Zehra, S. S. (2018) · UCL Discovery (University College London)
Stieglitz, T. (2010) · Bundesgesundheitsblatt - Gesundheitsforschung - Gesundheitsschutz
Wang, R., Yu, H., & Li, Z. (2018) · Micro/Nano technologies · doi:10.1007/978-981-10-5945-2_41
Peripheral Nerve Interface, Epineural Electrode
Fisher, L. E. (2022) · Springer eBooks · doi:10.1007/978-1-0716-1006-0_210
Peripheral Nerve Interface, Epineural Electrode
Fisher, L. E. (2015) · Springer eBooks · doi:10.1007/978-1-4614-6675-8_210
Modeling to Guide Implantable Electrode Design
Valle, G., & Micera, S. (2022) · River Publishers eBooks · doi:10.1201/9781003337973-5
Jakes, R. S., Alexander, B. J., Marcu, V., Ajiboye, A. B., & Tyler, D. J. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae0d31 · Cited by 1
Self-citationPaggi, V., Fallegger, F., Serex, L., Rizzo, O., Galan, K., Giannotti, A., Furfaro, I., Zinno, C., Bernini, F., Micera, S., et al. (2024) · Figshare · doi:10.6084/m9.figshare.25216803
Tigra, W., Dali, M., William, L., Fattal, C., Gélis, A., Divoux, J.-L., Coulet, B., Teissier, J., Guiraud, D., & Coste, C. (2020) · Figshare · doi:10.6084/m9.figshare.12332018
Toni, L., Fossati, V., Verardo, C., Losanno, E., Micera, S., & Romeni, S. (2026) · Research Square · doi:10.21203/rs.3.rs-10943457/v1
Metadata
- Authors
- Polasek, K. H., Hoyen, H. A., Keith, M. W., Kirsch, R. F., & Tyler, D. J.
- Affiliations
- Case Western Reserve University (US)
- MetroHealth Medical Center (US)
- Louis Stokes Cleveland VA Medical Center (US)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2009-10
- Volume
- 17
- Issue
- 5
- Pages
- 428-437
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- PMC
- PMC2927980
- OpenAlex
- W2128390902
- Cited by
- 142
- References
- 34
- Citations by year
- 2026: 4 · 2025: 7 · 2024: 8 · 2023: 5 · 2022: 7 · 2021: 10 · 2020: 9 · 2019: 10 · 2018: 12 · 2017: 9 · 2016: 11 · 2015: 9 · 2014: 10 · 2013: 15 · 2012: 6
- FWCI
- 2.22
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Case Western Reserve University
- National Institutes of Health (n01ns012333-006)
- National Institute of Neurological Disorders and Stroke (N01-NS-1-2333, R21NS058705, N01 NS012333)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Keywords
- cuff electrodes, chronic implantation, nerve conduction velocity, upper limb, functional electrical stimulation, multichannel stimulation, muscle recruitment
- MeSH terms
- Electrodes, Implanted, Electric Stimulation Therapy, Humans, Muscle Contraction, Paralysis, Prosthesis Design, Sensitivity and Specificity, Reproducibility of Results, Muscle, Skeletal, Equipment Failure Analysis, Upper Extremity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review