Cited by 73Neuroscience and Neural EngineeringMuscle activation and electromyography studiesEEG and Brain-Computer Interfaces

Localization and Recovery of Peripheral Neural Sources With Beamforming Algorithms

Open access
Wodlinger, Brian, Durand, Dominique M.·2009·IEEE Transactions on Neural Systems and Rehabilitation Engineering

Abstract

The peripheral nervous system carries sensory and motor information that could be useful as command signals for function restoration in areas such as neural prosthetics and functional electrical stimulation (FES). Nerve cuff electrodes provide a robust and safe technique for recording nerve signals. However, a method to separate and recover signals from individual fascicles is necessary. Prior knowledge of the electrode geometry was used to develop an algorithm which assumes neither signal independence nor detailed knowledge of the nerve's geometry/conductivity, and is applicable to any wide-band near-field situation. When used to recover fascicular activities from simulated nerve cuff recordings in a realistic human femoral nerve model, this beamforming algorithm separates signals as close as 1.5 mm with cross-correlation coefficient, R > 0.9 (10% noise). Ten simultaneous signals could be recovered from individual fascicles with only a 20% decrease in R compared to a single signal. At high noise levels (40%), sources were localized to 180 +/- 170 microm in the 12 x 3 mm cuff. Localizing sources and using the resulting positions in the recovery algorithm yielded R = 0.66 +/- 0.10 in 10% noise for five simultaneous muscle-activation signals from synergistic fascicles. These recovered signals should allow natural, robust, closed-loop control of multiple degree-of-freedom prosthetic devices and FES systems.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2009.2034072

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Data from multiple electrodes near the nerve can be used to estimate the origin of the signal using signal processing techniques such as spatial filtering.

    “In addition, the data from multiple electrodes near the nerve can be used to estimate the origin of the signal using various signal processing techniques, like spatial filtering (Wodlinger and Durand, 2009).”

    From Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics (2018) · cites this paper as Wodlinger and Durand, 2009

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 18

  1. [1]Loeb GE Peck RA Cuff Electrodes For Chronic Stimulation And Recording Of Peripheral Nerve Activity J Neurosci Methods 64 95 103 1 1996 8869489
  2. [3]Rozman J Zorko B Bunc M Selective Recording Of Electroneurograms From The Sciatic Nerve Of A Dog With Multi-Electrode Spiral Cuffs Jpn J Physiol 50 509 14 10 2000 11120917
  3. [4]Tesfayesus W Yoo P Moffitt M Durand DM Blind Source Separation Of Nerve Cuff Recordings Proceedings Of The 25th International Conference Of The Ieee/Embs Cancun, Mexico 2003 17271612
  4. [5]Tesfayesus W Durand DM Blind Source Separation Of Peripheral Nerve Recordings J Neural Eng 4 S157 67 9 2007 17873415
  5. [8]Zariffa J Popovic MR Solution Space Reduction In The Peripheral Nerve Source Localization Problem Using Forward Field Similarities Journal Of Neural Engineering 5 191 202 6 2008 18460742
  6. [9]Zariffa J Popovic MR Application Of Eeg Source Localization Algorithms To The Monitoring Of Active Pathways In Peripheral Nerves 30th Annual International Ieee Embs Conference Vancouver, British Columbia, Canada 2008 19163642
  7. [10]Sekihara K Nagarajan SS Adaptive Spatial Filters For Electromagnetic Brain Imaging Springer 2008
  8. [12]Weinstein D Zhukov L Johnson C Lead-Field Bases For Electroencephalography Source Imaging Ann Biomed Eng 28 1059 65 9 2000 11132189
  9. [14]Otsu N A Threshold Selection Method From Gray-Level Histograms Ieee Transactions On Systems, Man, And Cybernetics 9 62 66 1979
  10. [15]Schiefer MA Triolo RJ Tyler DJ A Model Of Selective Activation Of The Femoral Nerve With A Flat Interface Nerve Electrode For A Lower Extremity Neuroprosthesis Ieee Trans Neural Syst Rehabil Eng 16 195 204 4 2008 18403289 PMC2920206
  11. [16]Moore JW Joyner RW Brill MH Waxman SD Najar-Joa M Simulations Of Conduction In Uniform Myelinated Fibers. Relative Sensitivity To Changes In Nodal And Internodal Parameters Biophys J 21 147 60 2 1978 623863 PMC1473353
  12. [17]Meeks JP Jiang X Mennerick S Action Potential Fidelity During Normal And Epileptiform Activity In Paired Soma-Axon Recordings From Rat Hippocampus J Physiol 566 425 41 7 15 2005 15890699 PMC1464751
  13. [18]Jezernik S Sinkjaer T On Statistical Properties Of Whole Nerve Cuff Recordings Ieee Trans Biomed Eng 46 1240 5 10 1999 10513129
  14. [19]Kenneth E Hild I Erdogmus Deniz Príncipe José Blind Source Separation Using Renyi’s Mutual Information Ieee Signal Processing Letters 8 2001
  15. [20]Pascual-Marqui RD Standardized Low-Resolution Brain Electromagnetic Tomography (Sloreta): Technical Details Methods Find Exp Clin Pharmacol 24 Suppl D 5 12 2002 12575463
  16. [21]Gorodnitsky IF Rao BD Sparse Signal Reconstruction From Limited Data Using Focuss: A Re-Weighted Minimum Norm Algorithm Ieee Transactions On Signal Processing 45 600 616 3 1997
  17. [22]Han S Jeong KH Principe J Robust Adaptive Minimum Entropy Beamformer In Impulsive Noise Ieee Workshop On Machine Learning For Signal Processing 2007 437 440
  18. [24]Choi AQ Cavanaugh JK Durand DM Selectivity Of Multiple-Contact Nerve Cuff Electrodes: A Simulation Analysis Ieee Trans Biomed Eng 48 165 72 2 2001 11296872

Cited by

Sorted by citations

Authors
Wodlinger, B., & Durand, D. M.
Affiliations
Case Western Reserve University (US)
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2009-10
Volume
17
Issue
5
Pages
461-468
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2106364212
Cited by
73
References
2
Citations by year
2026: 1 · 2025: 2 · 2023: 2 · 2022: 6 · 2021: 2 · 2020: 8 · 2019: 6 · 2018: 6 · 2017: 3 · 2016: 9 · 2015: 2 · 2014: 7 · 2013: 1 · 2012: 4
FWCI
2.49
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
National Institute of Neurological Disorders and Stroke (R01NS032845)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
Keywords
beamforming, cuff electrodes, peripheral nerve recording, functional electrical stimulation, neuroprosthetics, feedback control
MeSH terms
Action Potentials, Algorithms, Animals, Computer Simulation, Electrodes, Implanted, Equipment Design, Humans, Models, Neurological, Peripheral Nerves, Sensitivity and Specificity, Reproducibility of Results, Computer-Aided Design, Equipment Failure Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review