Increased selectivity of clinical peripheral nerve interfaces
Abstract
Selective, spiral peripheral nerve interfaces have been implemented in several clinical applications. Modeling results and intraoperative validation studies of the Flat Interface Nerve Electrode (FINE) demonstrate that with single channel, monopolar stimulation the FINE can increase the selectivity of neural stimulation. We hypothesize the stimulation selectivity can be further improved and potentially equal to intrafascicular stimulation by more sophisticated stimulation fields and interfascicular placement of electrodes with directed stimulation surfaces. We have developed an accurate linear approximation to the double cable model that is fast enough to implement non-gradient descent optimization techniques. Simulations suggest that anodal surround field shaping and directed interfascicular stimulation can increase the stimulation selectivity without placing electrodes inside the fascicles.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Modeling studies have predicted that this effect could be avoided by implanting directional contacts adjacent to the fascicles.
“Modeling studies have predicted that this effect could be avoided by implanting directional contacts adjacent to the fascicles [55].”
From Directed stimulation with interfascicular interfaces for peripheral nerve stimulation (2021) · cites this paper as [55]
Cites
McIntyre, C. C., Richardson, A. G., & Grill, W. M. (2002) · Journal of Neurophysiology · doi:10.1152/jn.00353.2001 · Cited by 764 · see citing works
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398 · see citing works
Self-citationModeling the effects of electric fields on nerve fibers: Determination of excitation thresholds
Warman, E., Grill, W. M., & Durand, D. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.184700 · Cited by 328 · see citing works
Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
Yoshida, K., & Horch, K. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.243412 · Cited by 208 · see citing works
Schiefer, M. A., Triolo, R. J., & Tyler, D. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.918425 · Cited by 148 · see citing works
Self-citationFascicular perineurium thickness, size, and position affect model predictions of neural excitation
Grinberg, Y., Schiefer, M. A., Tyler, D. J., & Gustafson, K. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2010348 · Cited by 145 · cited 1× · see citing works
“activate [ 22 ]. This would significantly decrease the”
BackgroundChronic Response of the Rat Sciatic Nerve to the Flat Interface Nerve Electrode
Tyler, D. J., & Durand, D. M. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1569263 · Cited by 144 · see citing works
Self-citationPolasek, K. H., Hoyen, H. A., Keith, M. W., Kirsch, R. F., & Tyler, D. J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2032603 · Cited by 142 · see citing works
Self-citationSelective stimulation of the human femoral nerve with a flat interface nerve electrode
Schiefer, M. A., Polasek, K. H., Triolo, R. J., Pinault, G. C. J., & Tyler, D. J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026006 · Cited by 130 · see citing works
Self-citationHuman nerve stimulation thresholds and selectivity using a multi-contact nerve cuff electrode
Polasek, K. H., Hoyen, H. A., Keith, M. W., & Tyler, D. J. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891383 · Cited by 111 · see citing works
Self-citationTarler, M. D., & Mortimer, J. T. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.828415 · Cited by 110 · see citing works
Muscle recruitment with intrafascicular electrodes
Nannini, N., & Horch, K. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83589 · Cited by 94 · see citing works
Fabrication and characteristics of an implantable, polymer-based, intrafascicular electrode
Lawrence, S. M., Dhillon, G. S., & Horch, K. W. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(03)00231-0 · Cited by 93 · see citing works
Standing After Spinal Cord Injury With Four-Contact Nerve-Cuff Electrodes for Quadriceps Stimulation
Fisher, L. E., Miller, M. E., Bailey, S. N., Davis Jr., J. A., Anderson, J. S., Rhode, L., Tyler, D. J., & Triolo, R. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2003390 · Cited by 90 · see citing works
Self-citationFisher, L. E., Tyler, D. J., Anderson, J. S., & Triolo, R. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046010 · Cited by 89 · see citing works
Self-citationSubfascicle stimulation selectivity with the flat interface nerve electrode
Leventhal, D. K., & Durand, D. M. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1569266 · Cited by 81 · see citing works
Localization and Recovery of Peripheral Neural Sources With Beamforming Algorithms
Wodlinger, B., & Durand, D. M. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2034072 · Cited by 73 · see citing works
Predicting myelinated axon activation using spatial characteristics of the extracellular field
Peterson, E. J., Izad, O., & Tyler, D. J. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046030 · Cited by 64 · see citing works
Self-citationPrediction of Myelinated Nerve Fiber Stimulation Thresholds: Limitations of Linear Models
Moffitt, M. A., McIntyre, C. C., & Grill, W. M. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820382 · Cited by 64 · see citing works
Recruitment characteristics of nerve fascicles stimulated by a multigroove electrode
Koole, P., Holsheimer, J., Struijk, J. J., & Verloop, A. J. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559348 · Cited by 56 · see citing works
Chronic histological effects of the flat interface nerve electrode
Leventhal, D. K., Cohen, M., & Durand, D. M. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/2/004 · Cited by 43 · see citing works
Intraoperative evaluation of the spiral nerve cuff electrode on the femoral nerve trunk
Polasek, K. H., Schiefer, M. A., Pinault, G. C. J., Triolo, R. J., & Tyler, D. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/6/066005 · Cited by 33 · see citing works
Self-citationComputationally Efficient Method in Predicting Axonal Excitation
Izad, O. (2009) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 6 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133 · see citing works
Directed stimulation with interfascicular interfaces for peripheral nerve stimulation
Koppaka, S., Hess-Dunning, A., & Tyler, D. J. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac33e8 · Cited by 7 · see citing works
Self-citation
- Authors
- Tyler, D. J., Peterson, E. J., Brill, N., & White, K.
- Affiliations
- Case Western Reserve University (US)
- Venue
- 2011 5th International IEEE/EMBS Conference on Neural Engineering
- Publisher
- IEEE
- Published
- 2011-04
- Pages
- 257-260
- ISSN
- 1948-3554 (ISSN-L)
- OpenAlex
- W2149161039
- Cited by
- 10
- References
- 23
- Citations by year
- 2024: 2 · 2023: 1 · 2022: 1 · 2021: 1 · 2019: 2 · 2018: 1 · 2014: 1 · 2013: 1
- FWCI
- 1.81
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- International IEEE/EMBS Conference on Neural Engineering (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Pain Management and Treatment
- Keywords
- peripheral nerve interfaces, stimulation selectivity, neurostimulation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review