Continuous Detection and Decoding of Dexterous Finger Flexions With Implantable MyoElectric Sensors
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A rhesus monkey was trained to perform individuated and combined finger flexions of the thumb, index, and middle finger. Nine implantable myoelectric sensors (IMES) were then surgically implanted into the finger muscles of the monkey's forearm, without any adverse effects over two years postimplantation. Using an inductive link, EMG was wirelessly recorded from the IMES as the monkey performed a finger flexion task. The EMG from the different IMES implants showed very little cross correlation. An offline parallel linear discriminant analysis (LDA) based algorithm was used to decode finger activity based on features extracted from continuously presented frames of recorded EMG. The offline parallel LDA was run on intraday sessions as well as on sessions where the algorithm was trained on one day and tested on following days. The performance of the algorithm was evaluated continuously by comparing classification output by the algorithm to the current state of the finger switches. The algorithm detected and classified seven different finger movements, including individual and combined finger flexions, and a no-movement state (chance performance = 12.5%) . When the algorithm was trained and tested on data collected the same day, the average performance was 43.8+/-3.6% n=10. When the training-testing separation period was five months, the average performance of the algorithm was 46.5+/-3.4% n=8. These results demonstrated that using EMG recorded and wirelessly transmitted by IMES offers a promising approach for providing intuitive, dexterous control of artificial limbs where human patients have sufficient, functional residual muscle following amputation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Self-citation
Research works printed but not linked: 21
- schieber, 1991, individuated finger movements of rhesus monkeys: a means of quantifying the independence of the digits, J Neurophysiol, 65, 1381, 10.1152/jn.1991.65.6.1381 · DOI · Paper page
- 10.1109/IEMBS.2008.4649123 · DOI
- 10.1152/jn.00480.2004 · DOI · Paper page
- 10.1109/IEMBS.2007.4352644 · DOI
- 10.1109/IEMBS.2005.1616206 · DOI · Paper page
- 10.1109/IEMBS.2003.1279658 · DOI
- 10.1109/IEMBS.2006.259871 · DOI
- 10.1159/000147465 · DOI
- 10.1109/TBME.2006.881774 · DOI
- 10.1023/A:1008810007672 · DOI
- 10.1109/TBME.2008.2005942 · DOI · Paper page
- 10.1109/IEMBS.2008.4650414 · DOI
- 10.1109/TNSRE.2007.916269 · DOI · Paper page
- 10.1109/TBME.2008.2005485 · DOI · Paper page
- 10.1152/jn.00760.2006 · DOI
- 10.1109/TBME.2006.889192 · DOI · Paper page
- 10.1109/MSPEC.2009.4734314 · DOI
- schieber, 1995, muscular production of individuated finger movements: the roles of extrinsic finger muscles, J Neurosci, 15, 284, 10.1523/JNEUROSCI.15-01-00284.1995 · DOI · Paper page
- 10.1046/j.1525-1594.2002.06938.x · DOI · Paper page
- 10.1097/01.prs.0000242487.62487.fb · DOI · Paper page
- legere, 1993, isometric muscle fatigue effects on pattern recognition ability of a new myoelectric prosthesis control system, Myoelectric Controls Symp, 10
Cited by
Scheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Self-citationFlexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Classification of Simultaneous Movements Using Surface EMG Pattern Recognition
Young, A. J., Smith, L. H., Rouse, E. J., & Hargrove, L. J. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2232293 · Cited by 320
Current state of digital signal processing in myoelectric interfaces and related applications
Hakonen, M., Piitulainen, H., & Visala, A. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.02.009 · Cited by 305
Metadata
- Authors
- Baker, J. J., Scheme, E., Englehart, K., Hutchinson, D. T., & Greger, B.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2010-08
- Volume
- 18
- Issue
- 4
- Pages
- 424-432
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2113966143
- Cited by
- 77
- References
- 1
- FWCI
- 4.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous Detection and Decoding of Dexterous Finger Flexions With Implantable MyoElectric Sensors. https://app.cochat.ai/papers/10.1109/tnsre.2010.2047590
- The paper
- Baker, J. J., Scheme, E., Englehart, K., Hutchinson, D. T., & Greger, B. (2010). Continuous Detection and Decoding of Dexterous Finger Flexions With Implantable MyoElectric Sensors. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2010.2047590
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.