Determining the Optimal Window Length for Pattern Recognition-Based Myoelectric Control: Balancing the Competing Effects of Classification Error and Controller Delay
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Pattern recognition-based control of myoelectric prostheses has shown great promise in research environments, but has not been optimized for use in a clinical setting. To explore the relationship between classification error, controller delay, and real-time controllability, 13 able-bodied subjects were trained to operate a virtual upper-limb prosthesis using pattern recognition of electromyogram (EMG) signals. Classification error and controller delay were varied by training different classifiers with a variety of analysis window lengths ranging from 50 to 550 ms and either two or four EMG input channels. Offline analysis showed that classification error decreased with longer window lengths (p < 0.01 ). Real-time controllability was evaluated with the target achievement control (TAC) test, which prompted users to maneuver the virtual prosthesis into various target postures. The results indicated that user performance improved with lower classification error (p < 0.01 ) and was reduced with longer controller delay (p < 0.01 ), as determined by the window length. Therefore, both of these effects should be considered when choosing a window length; it may be beneficial to increase the window length if this results in a reduced classification error, despite the corresponding increase in controller delay. For the system employed in this study, the optimal window length was found to be between 150 and 250 ms, which is within acceptable controller delays for conventional multistate amplitude controllers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chiang, L. H., Russell, E. L., & Braatz, R. D. (2001) · Advanced Textbooks in Control and Signal Processing · doi:10.1007/978-1-4471-0347-9_3 · Cited by 5,003
Estimating the Prevalence of Limb Loss in the United States: 2005 to 2050
Ziegler-Graham, K., MacKenzie, E. J., Ephraim, P. L., Travison, T. G., & Brookmeyer, R. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.11.005 · Cited by 2,816
Pattern Classification (2nd ed.)
Duda, R. O., Hart, P. E., & Stork, D. G. (1999) · Cited by 2,520
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 1×
“absolute value, number of zero crossings, waveform length, and number of slope sign changes [15]) were extracted from the corresponding channels of EMG data in each analysis window.”
MethodA robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Self-citationSupport Vector Machine-Based Classification Scheme for Myoelectric Control Applied to Upper Limb
Oskoei, M. A., & Hu, H. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.919734 · Cited by 829
Classification of the myoelectric signal using time-frequency based representations
Englehart, K., Hudgins, B., Parker, P. A., & Stevenson, M. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00066-1 · Cited by 645
Huang, Y., Englehart, K. B., Hudgins, B., & Chan, A. D. C. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856295 · Cited by 643
A Comparison of Surface and Intramuscular Myoelectric Signal Classification
Hargrove, L. J., Englehart, K., & Hudgins, B. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889192 · Cited by 518
Self-citationQuantifying Pattern Recognition—Based Myoelectric Control of Multifunctional Transradial Prostheses
Li, G., Schultz, A. E., & Kuiken, T. A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039619 · Cited by 443
Self-citationThe optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438
A heuristic fuzzy logic approach to EMG pattern recognition for multifunctional prosthesis control
Ajiboye, A. B., & Weir, R. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847357 · Cited by 415
Chu, J.-U., Moon, I., & Mun, M.-S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883695 · Cited by 352
Continuous Myoelectric Control for Powered Prostheses Using Hidden Markov Models
Chan, A. D. C., & Englehart, K. B. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.836492 · Cited by 343
Hargrove, L. J., Scheme, E. J., Englehart, K. B., & Hudgins, B. S. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039590 · Cited by 219
Self-citationGraupe, D., Salahi, J., & Kohn, K. H. (1982) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(82)90021-8 · Cited by 205
Myoelectric Prostheses: state of the art
Scott, R. N., & Parker, P. A. (1988) · Journal of Medical Engineering & Technology · doi:10.3109/03091908809030173 · Cited by 171
Hargrove, L., Losier, Y., Lock, B., Englehart, K., & Hudgins, B. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4353424 · Cited by 150
Self-citationSignal processing for the multistate myoelectric channel
Parker, P. A., Stuller, J. A., & Scott, R. N. (1977) · Proceedings of the IEEE · doi:10.1109/proc.1977.10545 · Cited by 147
A review on linear mixed models for longitudinal data, possibly subject to dropout
Molenberghs, G., & Verbeke, G. (2001) · Statistical Modelling · doi:10.1177/1471082x0100100402 · Cited by 126
REAL-TIME MYOELECTRIC CONTROL IN A VIRTUAL ENVIRONMENT TO RELATE USABILITY VS. ACCURACY
Lock, B. A., Englehart, K. B., & Hudgins, B. (2005) · DukeSpace (Duke University) · Cited by 122
Self-citationA review of the methods of processing EMG for use as a proportional control signal.
Hogan, N. (1976) · PubMed · Cited by 83
A Three-Terminal Approach to Developing Spin-Torque Written Magnetic Random Access Memory Cells
Braganca, P. M., Katine, J. A., Emley, N. C., Mauri, D., Childress, J. R., Rice, P. M., Delenia, E., Ralph, D. C., & Buhrman, R. A. (2008) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2008.2005187 · Cited by 76
Error rate in five-state myoelectric control systems
Paciga, J. E., Richard, P. D., & Scott, R. N. (1980) · Medical & Biological Engineering & Computing · doi:10.1007/bf02443381 · Cited by 41
ANALYSIS WINDOW INDUCED CONTROLLER DELAY FOR MULTIFUNCTIONAL PROSTHESES
Farrell, T. R., & Weir, R. F. F. (2008) · DukeSpace (Duke University) · Cited by 26
Applying Genetic Programming To Control Of An Artificial Arm
Farry, K. A., Fernandez, J. J., Abramczyk, R., Novy, M., & Atkins, D. J. (1997) · DukeSpace (Duke University) · Cited by 23
Cited by
Deep Learning for Electromyographic Hand Gesture Signal Classification Using Transfer Learning
Cote-Allard, U., Fall, C. L., Drouin, A., Campeau-Lecours, A., Gosselin, C., Glette, K., Laviolette, F., & Gosselin, B. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2896269 · Cited by 738
A wearable biosensing system with in-sensor adaptive machine learning for hand gesture recognition
Moin, A., Zhou, A., Rahimi, A., Menon, A., Benatti, S., Alexandrov, G., Tamakloe, S., Ting, J., Yamamoto, N., Khan, Y., et al. (2020) · Nature Electronics · doi:10.1038/s41928-020-00510-8 · Cited by 680
Gesture recognition by instantaneous surface EMG images
Geng, W., Du, Y., Jin, W., Wei, W., Hu, Y., & Li, J. (2016) · Scientific Reports · doi:10.1038/srep36571 · Cited by 595
Surface EMG-Based Inter-Session Gesture Recognition Enhanced by Deep Domain Adaptation
Du, Y., Jin, W., Wei, W., Hu, Y., & Geng, W. (2017) · Sensors · doi:10.3390/s17030458 · Cited by 363
Parajuli, N., Sreenivasan, N., Bifulco, P., Cesarelli, M., Savino, S., Niola, V., Esposito, D., Hamilton, T. J., Naik, G. R., Gunawardana, U., et al. (2019) · Sensors · doi:10.3390/s19204596 · Cited by 332
Metadata
- Authors
- Smith, L. H., Hargrove, L. J., Lock, B. A., & Kuiken, T. A.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2011-04
- Volume
- 19
- Issue
- 2
- Pages
- 186-192
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2148268262
- Cited by
- 443
- References
- 27
- FWCI
- 12.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.