In Vitro and In Vivo Evaluation of PEDOT Microelectrodes for Neural Stimulation and Recording
The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Cortical neural prostheses require chronically implanted small-area microelectrode arrays that simultaneously record and stimulate neural activity. It is necessary to develop new materials with low interface impedance and large charge transfer capacity for this application and we explore the use of conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) for the same. We subjected PEDOT coated electrodes to voltage cycling between -0.6 and 0.8 V, 24 h continuous biphasic stimulation at 3 mC/cm² and accelerated aging for four weeks. Characterization was performed using cyclic voltammetry, electrochemical impedance spectroscopy, and voltage transient measurements. We found that PEDOT coated electrodes showed a charge injection limit 15 times higher than Platinum Iridium (PtIr) electrodes and electroplated Iridium Oxide (IrOx) electrodes when using constant current stimulation at zero voltage bias. In vivo chronic testing of microelectrode arrays implanted in rat cortex revealed that PEDOT coated electrodes show higher signal-to-noise recordings and superior charge injection compared to PtIr electrodes.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In the recent decade, various nanomaterials[301,345,534,535] and conductive polymers[536–538] have also made their way into implantable stimulation electrodes, which have higher charge injection capacity (1~15 mC cm−2) compared to conventional materials (Pt 0.05~0.15 mC cm−2, TiN 0.9 mC cm−2).[39]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [534]
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243 · cited 3×
“Many neuroprostheses applications require that the same electrodes also be used for single unit neural recording and this places stringent constraints on the maximum area of the electrodes (typically smaller than 4000 [7]).”
BackgroundElectrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 3×
“More complete models of the electrode interface have been presented elsewhere [6], [28].”
BackgroundResponse of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 2×
“to glial scar formation around the electrodes [32] and the nature of the in vivo electrolyte [33].”
BackgroundConducting‐Polymer Nanotubes for Controlled Drug Release
Abidian, M. R., Kim, D. ‐., & Martin, D. C. (2006) · Advanced Materials · doi:10.1002/adma.200501726 · Cited by 869
Self-citationConducting polymers for neural interfaces: Challenges in developing an effective long-term implant
Green, R. A., Lovell, N. H., Wallace, G. G., & Poole-Warren, L. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.047 · Cited by 691 · cited 1×
“PEDOT is an electrically conducting polymer which is being investigated for improving the long-term performance of microfabricated neural prosthetic devices [17].”
BackgroundSchmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672
Impedance Characterization and Modeling of Electrodes for Biomedical Applications
Franks, W., Schenker, I., Schmutz, P., & Hierlemann, A. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847523 · Cited by 659 · cited 1×
“A simple electrical model of the tissue-electrode interface (adopted from [27]) is shown in Fig.”
MethodLudwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638 · cited 3×
“However, previous results [21] agree with our observation that PEDOT coated electrodes show a small improvement in signal to noise ratio of recordings.”
BackgroundResultInfluentialSelf-citationCui, X., & Martin, D. C. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00448-3 · Cited by 573 · cited 3×
“PEDOT coatings on electrodes lead to significant reduction in electrical impedance and increase in charge injection in vitro [18], [19].”
BackgroundSelf-citationIn vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
Weiland, J. D., Anderson, D. J., & Humayun, M. S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805487 · Cited by 382 · cited 6×
“It should be noted that the IrOx used in this work was electroplated and activated IrOx (AIROF) or sputtered IrOx (SIROF) might lead to different results.”
BackgroundInfluential
Research works printed but not linked: 2
- 0, Standard Practice for Accelerated Aging of Ultra-High Molecular Weight Polyethylene after Gamma Irradiation in Air
- 0, Standard Guide for Accelerated Aging of Sterile Barrier Systems for Medical Devices
Cited by
Items 201–300 of 342
Flexible Depth Probes with PEDOT:PSS Microelectrodes for Chronic Recording and Stimulation
Cornuéjols, R., Ivanov, A., Ghestem, A., Albon, A., Ytier, C., Nordlund, M., Mercier, J., Bernard, C., & Rezaei‐Mazinani, S. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5c02872 · Cited by 17
Golabchi, A., Wu, B., Du, Z. J., & Cui, X. T. (2025) · Advanced NanoBiomed Research · doi:10.1002/anbr.202400114 · Cited by 18
Tian, H., Liu, J., Kang, X., Wei, D., Zhang, C., Du, J., Yang, B. T., Chen, X., & Yang, C. (2014) · RSC Advances · doi:10.1039/c4ra07265k · Cited by 17
Polymerization of PEDOT/PSS/Chitosan-Coated Electrodes for Electrochemical Bio-Sensing
Sui, L., Zhang, B., Wang, J., & Cai, A. (2017) · Coatings · doi:10.3390/coatings7070096 · Cited by 17
“Recent findings of the application of PEDOT in bioengineering and medical fields, such as conductive coatings for neural microelectrodes [4,5], drug delivery system [6,7], biosensors [8,9] and tissue engineering [10], have attracted attention.”
BackgroundLee, D., Moon, H. C., Tran, B.-T., Kwon, D.-H., Kim, Y. H., Jung, S., Joo, J. H., & Park, Y. S. (2018) · Experimental Neurobiology · doi:10.5607/en.2018.27.6.593 · Cited by 17
A tissue-engineered neural interface with photothermal functionality
do Nascimento, A. T., Mendes, A. X., Begeng, J. M., Duchi, S., Stoddart, P. R., Quigley, A. F., Kapsa, R. M. I., Ibbotson, M. R., Silva, S. M., & Moulton, S. E. (2023) · Biomaterials Science · doi:10.1039/d3bm00139c · Cited by 15
Ultra‐Flexible µ‐ECoG Arrays Based on PEDOT:PSS Micropillars
Lunghi, A., Bianchi, M., Greco, P., Viaro, R., Lauro, M. D., Fadiga, L., & Biscarini, F. (2025) · Advanced Materials Interfaces · doi:10.1002/admi.202500051 · Cited by 15
Aqrawe, Z., Patel, N. D., Vyas, Y., Bansal, M., Montgomery, J. M., Travaš‐Sejdić, J., & Svirskis, D. M. (2020) · PLoS ONE · doi:10.1371/journal.pone.0237709 · Cited by 16
“Biocompatibility assessment is carried out through the growth of cell cultures onto an MEA in vitro [8, 17, 18] and foreign body responses to implanted electrode arrays in vivo [10, 13, 19].”
BackgroundGaunt, R. A., Bruns, T. M., Crammond, D. J., Tomycz, N. D., Moossy, J. J., & Weber, D. J. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091655 · Cited by 14
“A reduction in the impedance of the electrodetissue interface using surface modification techniques [5], [6] would also likely lead to an improvement in the yield of useful signals.”
BackgroundFabrication and ex vivo evaluation of activated carbon–Pt microparticle based glutamate biosensor
Nguyen, T. N. H., Nolan, J. K., Cheng, X., Park, H., Wang, Y., Lam, S., Lee, H., Kim, S. J., Shi, R., Chubykin, A. A., et al. (2020) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2020.114136 · Cited by 15
“5 orders of magnitude lower than that of C-Pt-PEDOT:PSS electrodes at 1 kHz, which is a commonly used metric for average impedance of electrode [30].”
BackgroundA trade-off between antifouling and the electrochemical stabilities of PEDOTs
Zhang, Y., Lin, H., Pan, Q., Qian, S.-H., Zhang, S., Zhuang, A., Zhang, S., Qiu, G., Cieplak, M., Sharma, P. S., et al. (2021) · Journal of Materials Chemistry B · doi:10.1039/d0tb01797c · Cited by 14
Open-source Toolkit: Benchtop Carbon Fiber Microelectrode Array for Nerve Recording
Richie, J. M., Patel, P. R., Welle, E. J., Dong, T., Chen, L., Shih, A. J., & Chestek, C. A. (2021) · Journal of Visualized Experiments · doi:10.3791/63099 · Cited by 14
ElMahmoudy, M., Curto, V. F., Ferro, M. D., Hama, A., Malliaras, G. G., O'Connor, R. P., & Sanaur, S. (2018) · Journal of Applied Polymer Science · doi:10.1002/app.47029 · Cited by 14
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1807.07590 · Cited by 14
Self-citationSaghir, S., Imenes, K., & Schiavone, G. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1150147 · Cited by 13
“For instance, it has been demonstrated that metal electrodes coated with organic conductors can outperform uncoated controls (Khodagholy et al., 2011; Venkatraman et al., 2011).”
BackgroundPorous PU/PEDOT:PSS electrodes for probing bioelectricity in Oscillatoria sp. Cohorts
Cotta, F. C., Correia, D., Amaral, R., Bacellar, F. L., Duci, D., Lopes, L., Cortes, L., Zalar, P., Perkins, R. G., & Rocha, P. R. F. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.155480 · Cited by 13
Modulation of the electrical double layer in metals and conducting polymers
Morgado, J. (2022) · Scientific Reports · doi:10.1038/s41598-021-03948-8 · Cited by 15
Wang, M., Ye, F., Li, L., Wen, F., Guo, B., Jin, M., Xu, J., Zhou, Y., Kang, X., Ji, B., et al. (2022) · Micromachines · doi:10.3390/mi13020199 · Cited by 13
Brunton, E., Winther‐Jensen, B., Wang, C., Yan, E. B., Gooie, S. H., Lowery, A. J., & Rajan, R. (2015) · Frontiers in Neuroengineering · doi:10.3389/fneng.2015.00005 · Cited by 17
Electrodes for Long-Term Esophageal Electrocardiography
Niederhäuser, T., Haeberlin, A., Marisa, T., Jungo, M., Goette, J., Jacomet, M., Abächerli, R., & Vogel, R. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2261067 · Cited by 14
“Nevertheless, the surface characteristics of PEDOT are not impaired and similar values for Rp and Cp as compared to TiN and IrOx are observed.”
BackgroundRen, G., Yang, J., Wang, X., Hu, G., Chen, H., Fang, Q., & Yang, A. (2025) · ACS Applied Polymer Materials · doi:10.1021/acsapm.4c04052 · Cited by 13
Fabrication of iridium oxide neural electrodes at the wafer level
Zhang, H., Pei, W., Zhao, S., Yang, X., Liu, R., Liu, Y., Wu, X. M., Guo, D., Gui, Q., Guo, X., et al. (2016) · Science China Technological Sciences · doi:10.1007/s11431-016-6099-x · Cited by 12
Electrodeposited coatings for neural electrodes: A review
Li, L., & Jiang, C. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117492 · Cited by 11
Yang, X., Pei, W., Wei, C., Yang, X., Zhang, H., Wang, Y., Yuan, M., Gui, Q., Liu, Y., Wang, Y., et al. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.114022 · Cited by 11
Focalizing electrical neural stimulation with penetrating microelectrode arrays: A modeling study
Joucla, S., Rousseau, L., & Yvert, B. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.05.006 · Cited by 11
“Such low impedance material corresponds typically to porous metal layers such as black-Pt or more advanced and robust nano or macro/meso-porous structures, which are the focus of current developments (Venkatraman et al., 2011; Heim et al., 2012a) (see also Heim et al., 2012b).”
BackgroundDesigning parylene coating for implantable brain–machine interfaces
Ebrahimibasabi, S., Golshahi, M., Shahraki, N., Shabestari, D. T., Sajjadi, M., Hashemi, S., Borchert, A., Baker, I., Khalifehzadeh, L., & Arami, H. (2025) · RSC Advances · doi:10.1039/d5ra04683a · Cited by 10
Improving Fast Ripples Recording With Model-Guided Design of Microelectrodes
Harrach, M. A., Dauly, G., Mousavi, H., Dieuset, G., Benquet, P., Ismailova, E., & Wendling, F. (2023) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2023.3250763 · Cited by 10
Wang, A. Y., Jung, D., Park, J.-S., Junek, G. V., & Wang, H. (2019) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2019.2905509 · Cited by 10
“may generate undesired electrochemical reactions, damage electrodes, and harm nearby tissues [9], [16]–[18].”
BackgroundElizalde, M. L. M., Acha, C., Moreno, M. S., & Antonel, P. S. (2022) · Journal of Materials Chemistry C · doi:10.1039/d2tc03175b · Cited by 10
Electrodes and instrumentation for neurostimulation
Merrill, D. R. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00002-2 · Cited by 11
Wu, Y., Nagane, S. S., Baugh, Q., Lo, C., Chhatre, S. S., Lee, J., Sitarik, P., Kayser, L. V., & Martin, D. C. (2023) · Giant · doi:10.1016/j.giant.2023.100163 · Cited by 9
Self-citationA Dual Function Conductive Nano Ink for Printed Electronics Connections
Pradhan, S., & Yadavalli, V. K. (2023) · Organic Electronics · doi:10.1016/j.orgel.2023.106959 · Cited by 9
Kassanos, P., Florent Seichepine, A., & Yang, G. (2019) · IEEE International Conference on Bioinformatics and Bioengineering (BIBE) · doi:10.1109/bibe.2019.00129 · Cited by 9
“Platinum black [19], PEDOT:PSS [20], carbon nanotube (CNT) and composite PEDOT-CNT [21] depositions, are among the approaches to achieve this that we are currently examining.”
BackgroundElectroceuticals for neural regenerative nanomedicine
Tomaskovic‐Crook, E., Higginbottom, S. L., James, E. C., Rathbone, S. J. C., & Crook, J. M. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-820223-4.00007-3 · Cited by 12
Conducting Polymers to Control and Monitor Cells
Jimison, L. H., Rivnay, J., & Owens, R. M. (2013) · Wiley eBooks · doi:10.1002/9783527650965.ch02 · Cited by 9
Ye, Y., Tian, Y., Liu, H., Liu, J., Zhou, C., Xu, C., Zhou, T., Nie, Y., Wu, Y. C., Qin, L., et al. (2025) · Exploration · doi:10.1002/exp.70040 · Cited by 8
“The 60 ◦ C immersion for 4 weeks, known as an accelerated aging test, is equivalent to approximately 20 weeks at body temperature (37 ◦ C), according to ASTM guidelines [26].”
Biosynthetic conductive polymer composites for tissue-engineering biomedical devices
Green, R. A., & Goding, J. A. (2015) · Elsevier eBooks · doi:10.1016/b978-1-78242-105-4.00011-0 · Cited by 12
A Fibre-Optic Platform for Sensing Nitrate Using Conducting Polymers
Shahnia, S., Ebendorff‐Heidepriem, H., Evans, D., & Shahraam Afshar, V. (2020) · Sensors · doi:10.3390/s21010138 · Cited by 8
Tuermer-Lee, J. X., Lim, A., Ah, L., Blau, R., Qie, Y., Shipley, W., Kayser, L. V., Russman, S. M., Tao, A. R., Dayeh, S. A., et al. (2023) · ACS Macro Letters · doi:10.1021/acsmacrolett.3c00514 · Cited by 8
Schander, A., Stemmann, H., Kreiter, A. K., & Lang, W. (2017) · EUROSENSORS Conference (EUROSENSORS) · doi:10.3390/proceedings1040511 · Cited by 8
Idogawa, S., Yamashita, K., Kubota, Y., Sawahata, H., Sanda, R., Yamagiwa, S., Numano, R., Koida, K., & Kawano, T. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.128442 · Cited by 8
Xu, S., Deng, Y., Luo, J., Liu, Y., He, E., Yang, Y. F., Zhang, K., Sha, L., Dai, Y., Tao, M., et al. (2022) · Biosensors · doi:10.3390/bios12070546 · Cited by 8
Characteristics of PEDOT:PSS thin films spin-coated on ITO
Broski, A., Guo, Y., Khan, W., & Li, W. (2017) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems.2017.8017016 · Cited by 8
Dong, M., Coleman, H. A., Tonta, M. A., Xiong, Z., Li, D., Thomas, S., Liu, M., Fallon, J. B., Parkington, H. C., & Forsythe, J. S. (2022) · Nanoscale · doi:10.1039/d2nr04421h · Cited by 7
Multi-Channel Microscale Nerve Cuffs for Spatially Selective Neuromodulation
Riley, M., Tala, F., Johnson, K. J., & Johnson, B. C. (2024) · Micromachines · doi:10.3390/mi15081036 · Cited by 6
“Furthermore, PEDOT:PSS’s superior charge and discharge capability is important for closed-loop neuromodulation where recording starts immediately after stimulation (Figure 2A) [58,59] and has been shown to be a better neural recording electrode material with higher SNRs [60].”
BackgroundSitarik, P., & Martin, D. C. (2022) · ChemElectroChem · doi:10.1002/celc.202200231 · Cited by 6
Self-citationPEDOT:PSS coated gold nanopillar microelectrodes for neural interfaces
Nick, C., Thielemann, C., & Schlaak, H. F. (2014) · IEEE International Conference on Manipulation, Manufacturing and Measurement on the Nanoscale (3M-NANO) · doi:10.1109/3m-nano.2014.7057309 · Cited by 6
“The conducting polymer Poly(3,4-ethylenedioxy-thiophene) (PEDOT) also provides a low impedance [15-17], high charge injection capacities [18-21] and high stability [22-24].”
BackgroundHung, J.-N., Vo, D. N. K., Ho, H. P. T., & Tsai, M. (2022) · Biomacromolecules · doi:10.1021/acs.biomac.2c00271 · Cited by 6
Are ‘Next Generation’ Bioelectronics Being Designed Using Old Technologies?
Green, R. A. (2018) · Bioelectronics in Medicine · doi:10.2217/bem-2018-0008 · Cited by 6
Electrode Materials: State-of-the-Art and Experiments
Aryan, N. P., Kaim, H., & Rothermel, A. (2014) · Springer briefs in electrical and computer engineering · doi:10.1007/978-3-319-10052-4_6 · Cited by 8
A tassel-type multilayer flexible probe for invasive neural recording
Ye, Z.-P., Jing, Q., Ni, Y.-L., Wu, Z., Xiao, X., & Xiong, S. (2022) · Chip · doi:10.1016/j.chip.2022.100024 · Cited by 5
Killilea, J., Lee, A., Cuttaz, E. A., Miceli, G. C., Suquia, L. L., Goding, J. A., Chapman, C. A. R., & Green, R. A. (2025) · Advanced NanoBiomed Research · doi:10.1002/anbr.202400149 · Cited by 6
Benchtop Carbon Fiber Microelectrode Array Fabrication ToolkitPreprint
Richie, J., Patel, P. R., Welle, E. J., Dong, T., Chen, L., Shih, A. J., & Chestek, C. A. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.03.22.436422 · Cited by 5
“Our current tip coating, PEDOT:pTS, may also need to be replaced as it tends to degrade overtime, which is an undesirable trait for a chronic probe [35], [44], [54].”
BackgroundFlexible Microelectrode Arrays with Enhanced Electrochemical Properties Using Platinum Ditelluride
Jeanpierre, G. M., Omodon, S. C., Goldberg, S. D., González, J., Lu, H., Han, S. S., Baker, M. N., Madariaga, A., Rausch, M. K., Jung, Y., et al. (2025) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.5c01581 · Cited by 4
Chan, K. S., Guo, Y., Duan, Q., Wang, X., Hao, Y., Wu, S., & Dai, X. (2026) · ACS Nano · doi:10.1021/acsnano.6c05215 · Cited by 5
Shang, S., Xu, Y., Jin, M., Ni, C., Jiang, H., Wang, X., Wang, X., Cheng, Y., Wang, M., Zhang, S., et al. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2024.136891 · Cited by 4
Leusmann, E., Abkai, C., Tittelbach, M., & Poppendieck, W. (2024) · PLoS ONE · doi:10.1371/journal.pone.0315779 · Cited by 4
Electrically Conductive Polymers and Composites for Biomedical Applications
Haryanto, H., & Khan, M. M. (2018) · Wiley eBooks · doi:10.1002/9783527807918.ch11 · Cited by 5
Central nervous system responses to biomaterials
Tsintou, M., Wróbel, P. P., & Dalamagkas, K. (2020) · Elsevier eBooks · doi:10.1016/b978-0-08-102967-1.00023-2 · Cited by 4
CyberRat Probes: High-Resolution Biohybrid Devices for Probing the Brain
Vassanelli, S., Felderer, F., Mahmud, M., Maschietto, M., & Girardi, S. (2012) · Lecture notes in computer science · doi:10.1007/978-3-642-31525-1_24 · Cited by 4
Hébert, C., Ruffinatto, S., & Bergonzo, P. (2014) · Springer eBooks · doi:10.1007/978-3-319-08648-4_9 · Cited by 7
Artifact-free, high-temporal-resolution in vivo opto-electrophysiology with microLED optoelectrodesPreprint
Kim, K., Vöröslakos, M., Seymour, J. P., Wise, K. D., Buzsáki, G., & Yoon, E. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/622670 · Cited by 4
High-Stability Polyimide-based Flexible Electrodes with IrO x to Interface the Mouse Vagus NervePreprint
Sun, T., Falcone, J., Crosfield, C., Lopez, M. F., Peragine, J., Modi, R., Sharma, R., Baker, B., Anderson, G., Savani, S., et al. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.05.10.442867 · Cited by 5
“PEDOT performance in long-term testing is still unknown [40].”
BackgroundFolch, A. (2016) · CRC Press eBooks · doi:10.1201/b12263-12 · Cited by 4
Moghadam, M. T. T., & Cysewska, K. (2025) · Advanced Materials Interfaces · doi:10.1002/admi.202500263 · Cited by 3
Impact of Ethylene Oxide Sterilization on PEDOT:PSS Electrophysiology Electrodes
Maziz, A., Cointe, C., Reig, B., & Bergaud, C. (2026) · Sensors · doi:10.3390/s26030877 · Cited by 3
Avdeew, Y., Bergé-Laval, V., Rolle, V. L., Dieuset, G., Moreau, D., Kergoat, L., Martin, B., Bernard, C., Gestreau, C., & Hernandez, A. I. (2021) · Sensors · doi:10.3390/s21165594 · Cited by 4
“also compared PEDOT:PSS electrodes with PtIr and IrOx electrodes, and found out that PEDOT:PSS coated microelectrodes exhibit superior performances than PtIr electrodes in terms of both recordings and stimulation and present as well superior charge injection limits than IrOx electrodes at 0 DC bias voltage [44].”
BackgroundOsmani, R. A. M., Singh, E., Kazi, H., Bhosale, R. R., Vaghela, R., & Patravale, V. B. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-91248-8.00001-5 · Cited by 5
Medeiros, M. C. R., Mestre, A. L. G., Inácio, P. M. C., Santos, J. M. A., Araújo, I. M., Bragança, J., Biscarini, F., & Gomes, H. L. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2237659 · Cited by 3
Nanoelectronics for Neuroscience
Rastogi, S. K., & Cohen‐Karni, T. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.99893-3 · Cited by 3
Flexible Composites Based on PEDOT:PSS for Environmentally Friendly Electrocardiography Electrodes
Vergara, M. E. S., Flores, J. M. R., Martínez-Alanís, M., Guerra-Hernández, S. F., & Cosme, I. (2026) · Polymers · doi:10.3390/polym18080947 · Cited by 2
“Furthermore, the structural organization of PEDOT:PSS gives it a porous structure that allows for facile doping of the polymer to enhance its conductivity [11].”
Lee, Y. J., Song, K., Kang, J. Y., & Lee, S. H. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319126 · Cited by 3
1.29 Electroactive Polymeric Biomaterials ☆
Povlich, L. K., Feldman, K. E., Wei, B., Eom, T., Shim, B. S., & Martin, D. C. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.10233-4 · Cited by 3
Self-citationBailey, Z., Nairac, Z., Cuttaz, E. A., M’Rad, I. B., Chapman, C. A. R., Rapeaux, A., Goding, J. A., Roche, A. D., Constandinou, T. G., & Green, R. A. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae44d0 · Cited by 2
“The measured 40 nC of injected current concurs with charge thresholds reported for similar nerve cuff experiments [35, 36] and is within the safety limits for PEDOT-based electrodes [37].”
Shen, X., Zhao, Y., Li, Q., & Chen, T. (2020) · AIP Advances · doi:10.1063/5.0003595 · Cited by 2
Electronic and ionic transport in organic materials and devices
Romele, P., Kovacs-Vajna, Z. M., & Torricelli, F. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818890-3.00003-5 · Cited by 3
Bioelectronics and Neural Interfaces
Tong, W., Robles, U. A. A., & Gelmi, A. A. (2021) · Royal Society of Chemistry eBooks · doi:10.1039/9781788019828-00180 · Cited by 2
Zhou, C., Xu, Y., Wang, M., Jiang, H., Wang, W., Zhou, X., Zhao, X., Wang, P., Wang, X., Yang, W., et al. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.180921 · Cited by 1
Application of Advanced Composite Gel as Interface Material for Electrodes in Electroencephalography
Romanov, A., Кириллова, Д. А., Slezkin, A. A., Strelnikova, E. V., Vakhnitskaya, E., & Gotovtsev, P. M. (2025) · Ural Symposium on Biomedical Engineering, Radioelectronics and Information Technology (USBEREIT) · doi:10.1109/usbereit65494.2025.11054212 · Cited by 1
Shi, C., Li, W., He, F., Ma, J., Jia, P., Huo, W., & Pei, D. (2025) · Journal of Environmental Sciences · doi:10.1016/j.jes.2025.11.044 · Cited by 1
Li, M., Ly, C. M., Wen, J., Rustogi, P., & Meng, E. F. (2026) · Bioelectronic Medicine · doi:10.1186/s42234-025-00199-0 · Cited by 1
“…barrier to protect metal electrodes from corrosion due to oxygen reduction in the presence of reactive oxygen species and during the cathodic phase of the stimulation waveform, if the coating has strong adhesion and is defect-free ( Duan et al. 2024; Paulsen et al. 2020; Venkatraman et al. 2011).”
Su, J., Wang, H., Han, L., Cheng, R., Hao, R., & Sang, S. (2026) · Journal of Zhejiang University. Science A · doi:10.1631/jzus.a2600114 · Cited by 1
Chen, S., Pei, W., Gui, Q., Chen, Y., Zhao, S., & Chen, H. (2013) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems.2013.6559758 · Cited by 1
“2%wt polyanionic poly(sodium styrene sulfonate) (PSS) in deionized water were dispersed under ultrasonic irradiation for 1 hour to form a fully electropolymerization of PEDOT [7].”
MethodPEDOT:PSS as a transparent electrically conducting polymer for brain stimulation electrodes
Rathi, S., Deckert, M., Brinkhues, S., Detert, M., Shukla, S. M., Brosch, M., & Schmidt, B. (2019) · IEEE India Conference · doi:10.1109/indicon47234.2019.9030320 · Cited by 1
Towards All-Polymeric Cochlear Implant Micro-Electrode Arrays
Miralles-Abete, A., & French, P. J. (2021) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors47087.2021.9639615 · Cited by 1
“Therefore, in this section, PEDOT:PSS and platinum electrodes are electrically characterised to compare their maximum CIC.”
BackgroundInfluentialCoatings for Microneural Implants: Electrical Considerations
Olczak, K. P., & Otto, K. J. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_7 · Cited by 1
Polyravas, A. G., Proctor, C. M., Curto, V. F., Carnicer‐Lombarte, A., Malliaras, G. G., & Barone, D. G. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_106 · Cited by 1
Electrophysiological Techniques for Studying Tactile Perception in Rats
Öztürk, S., Devecıoğlu, İ., Vardar, B., Duvan, F. T., & Güçlü, B. (2023) · Neuromethods · doi:10.1007/978-1-0716-3068-6_16 · Cited by 1
Tavakol, S., Zahmatkeshan, M., & Rahvar, M. (2023) · ACS symposium series · doi:10.1021/bk-2023-1438.ch010 · Cited by 1
Carbon based materials for recording and stimulating the visual pathway
Nguyen, D. (2020) · theses.fr (ABES) · doi:10.70675/76199427z9dcaz4283z836czd6bb23a540da · Cited by 1
A graphene oxide nanocomposite for neural interfacing applications
Weaver, C. L. (2014) · D-Scholarship@Pitt (University of Pittsburgh)
Cunningham, J. M. (2017) · ERA: Education and Research Archive (University of Alberta) · doi:10.7939/r3mk65n9h
Life time assessment of microelectrodes for neural stimulation applications
González‐Losada, P., Grzeskowiak, M., Rousseau, L., Lissorgues, G., & Scorsone, E. (2018) · Symposium on Design, Test, Integration & Packaging of MEMS and MOEMS (DTIP) · doi:10.1109/dtip.2018.8394229
“The recent studies on these materials have been focused mostly on their electrical performance, biocompatibility and in vivo stability [3, 6, 7, 8].”
BackgroundTokuda, T., Ohta, J., Tashiro, H., & Terasawa, Y. (2018) · Wiley eBooks · doi:10.1002/047134608x.w8370
Micro- and nano-patterning of conducting polymers for biomedical applications
ElMahmoudy, M. (2017) · theses.fr (ABES) · doi:10.70675/42811ce9z8301z470az9097zbf5ad4be12af · Cited by 1
Pas, J. (2017) · theses.fr (ABES) · doi:10.70675/d28426d3z2c05z40b0za9b0zf1e9d3cfeec0 · Cited by 3
“Examples of such modifiications include porous platinum black, golden nanoflakes or -pillars, carbon nanotubes, conducting polymers such as polypyrrole and poly(3,4-ethylenedioxythiophene):poly (styrenesulfonate) (PEDOT:PSS) [47], [50], [55], [71],”
BackgroundStretchable electronics towards the fabrication of organic sensors for artificial skin
Marchiori, B. (2018) · theses.fr (ABES) · doi:10.70675/8745945czcee1z424ezb69az15a1e62ec8cb
Vallejo‐Giraldo, C., Ouidja, M. O., Huynh, M. B., Trotier, A., Krukiewicz, K., Pallipurath, A. R., Flannery, A., Kilcoyne, M., Pandit, A., Papy-García, D., et al. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.05.11.443655
Metadata
- Authors
- Venkatraman, S., Hendricks, J., King, Z. A., Sereno, A. J., Richardson-Burns, S., Martin, D., & Carmena, J. M.
- Affiliations
- Qualcomm (United States) (US)
- University of Michigan (US)
- University of Delaware (US)
- University of California, Berkeley (US)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2011-06
- Volume
- 19
- Issue
- 3
- Pages
- 307-316
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2154453638
- Semantic Scholar
- 96d94eb9fafb6c12897a64e2988fae1ba6d9b7f3
- Cited by
- 319
- References
- 39
- Citations by year
- 2026: 16 · 2025: 22 · 2024: 14 · 2023: 30 · 2022: 28 · 2021: 24 · 2020: 35 · 2019: 24 · 2018: 24 · 2017: 27 · 2016: 16 · 2015: 20 · 2014: 12 · 2013: 14 · 2012: 11
- FWCI
- 5.16
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Keywords
- PEDOT, conducting polymers, neural microelectrodes, neurostimulation, neural recording, neural prostheses, charge injection limit, electrode impedance, chronic implantation, cortical implants, platinum-iridium electrodes, iridium oxide electrodes, signal-to-noise ratio, voltage cycling, accelerated aging
- MeSH terms
- Animals, Electric Stimulation, Electrodes, Electrodes, Implanted, Electronics, Female, Iridium, Microelectrodes, Neurons, Polymers, Prosthesis Design, Rats, Sprague-Dawley, Bridged Bicyclo Compounds, Heterocyclic, Rats, Neural Prostheses
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.