In Vitro and In Vivo Evaluation of PEDOT Microelectrodes for Neural Stimulation and Recording
The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Cortical neural prostheses require chronically implanted small-area microelectrode arrays that simultaneously record and stimulate neural activity. It is necessary to develop new materials with low interface impedance and large charge transfer capacity for this application and we explore the use of conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) for the same. We subjected PEDOT coated electrodes to voltage cycling between -0.6 and 0.8 V, 24 h continuous biphasic stimulation at 3 mC/cm² and accelerated aging for four weeks. Characterization was performed using cyclic voltammetry, electrochemical impedance spectroscopy, and voltage transient measurements. We found that PEDOT coated electrodes showed a charge injection limit 15 times higher than Platinum Iridium (PtIr) electrodes and electroplated Iridium Oxide (IrOx) electrodes when using constant current stimulation at zero voltage bias. In vivo chronic testing of microelectrode arrays implanted in rat cortex revealed that PEDOT coated electrodes show higher signal-to-noise recordings and superior charge injection compared to PtIr electrodes.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In the recent decade, various nanomaterials[301,345,534,535] and conductive polymers[536–538] have also made their way into implantable stimulation electrodes, which have higher charge injection capacity (1~15 mC cm−2) compared to conventional materials (Pt 0.05~0.15 mC cm−2, TiN 0.9 mC cm−2).[39]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [534]
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243 · cited 3×
“Many neuroprostheses applications require that the same electrodes also be used for single unit neural recording and this places stringent constraints on the maximum area of the electrodes (typically smaller than 4000 [7]).”
BackgroundElectrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 3×
“More complete models of the electrode interface have been presented elsewhere [6], [28].”
BackgroundResponse of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 2×
“to glial scar formation around the electrodes [32] and the nature of the in vivo electrolyte [33].”
BackgroundConducting‐Polymer Nanotubes for Controlled Drug Release
Abidian, M. R., Kim, D. ‐., & Martin, D. C. (2006) · Advanced Materials · doi:10.1002/adma.200501726 · Cited by 869
Self-citationConducting polymers for neural interfaces: Challenges in developing an effective long-term implant
Green, R. A., Lovell, N. H., Wallace, G. G., & Poole-Warren, L. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.047 · Cited by 691 · cited 1×
“PEDOT is an electrically conducting polymer which is being investigated for improving the long-term performance of microfabricated neural prosthetic devices [17].”
BackgroundSchmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672
Impedance Characterization and Modeling of Electrodes for Biomedical Applications
Franks, W., Schenker, I., Schmutz, P., & Hierlemann, A. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847523 · Cited by 659 · cited 1×
“A simple electrical model of the tissue-electrode interface (adopted from [27]) is shown in Fig.”
MethodLudwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638 · cited 3×
“However, previous results [21] agree with our observation that PEDOT coated electrodes show a small improvement in signal to noise ratio of recordings.”
BackgroundResultInfluentialSelf-citationCui, X., & Martin, D. C. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00448-3 · Cited by 573 · cited 3×
“PEDOT coatings on electrodes lead to significant reduction in electrical impedance and increase in charge injection in vitro [18], [19].”
BackgroundSelf-citationIn vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
Weiland, J. D., Anderson, D. J., & Humayun, M. S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805487 · Cited by 382 · cited 6×
“It should be noted that the IrOx used in this work was electroplated and activated IrOx (AIROF) or sputtered IrOx (SIROF) might lead to different results.”
BackgroundInfluentialAbidian, M. R., & Martin, D. C. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.11.022 · Cited by 338 · cited 1×
“More complete models of the electrode interface have been presented elsewhere [6], [28].”
Self-citationEffects of Layer Thickness and Annealing of PEDOT:PSS Layers in Organic Photodetectors
Friedel, B., Keivanidis, P. E., Brenner, T. J. K., Abrusci, A., McNeill, C. R., Friend, R. H., & Greenham, N. C. (2009) · Macromolecules · doi:10.1021/ma901182u · Cited by 292 · cited 2×
“It is possible to increase the charge injection limit obtained with PEDOT electrodes by increasing the thickness of the coatings [30].”
BackgroundPoly (3,4-Ethylenedioxythiophene) for Chronic Neural Stimulation
Cui, X. T., & Zhou, D. D. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.909811 · Cited by 277 · cited 3×
“Similar substrate dependent mechanical delamination of PEDOT has been reported in other studies [20], [31].”
BackgroundMethodResultCell attachment functionality of bioactive conducting polymers for neural interfaces
Green, R. A., Lovell, N. H., & Poole-Warren, L. A. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.03.043 · Cited by 258 · cited 1×
“cation with physiologically active species [40], [41] to enhance”
BackgroundAccelerated aging for testing polymeric biomaterials and medical devices
Hukins, D. W. L., Mahomed, A., & Kukureka, S. N. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.06.001 · Cited by 247 · cited 1×
“These methods were adapted from [23], ASTM Standard F2003-02(2008) [24] and ASTM Standard F1980-07 [25].”
MethodButovas, S., & Schwarz, C. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00245.2003 · Cited by 246 · cited 1×
“This would simplify the design of circuits for artifact reduction and allow us to study the initial neural response to microstimulation that typically occurs 2‐5 ms after stimulation [ 38 ], [39].”
BackgroundActivated Ir: An Electrode Suitable for Reversible Charge Injection in Saline Solution
Robblee, L. S., Lefko, J. L., & Brummer, S. B. (1983) · Journal of The Electrochemical Society · doi:10.1149/1.2119793 · Cited by 227 · cited 1×
“IrOx is considered a promising alternative and can be formed by electroplating iridium oxide [9], by electrochemical activation of iridium (AIROF) [8], [10], or by reactive sputtering in an oxidizing plasma (SIROF) [11]–[13].”
BackgroundBeebe, X., & Rose, T. L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.2122 · Cited by 219 · cited 2×
“been reported for both IrOx [14], [22], [34] and PEDOT [19],”
MethodResultMarzouk, S. A. M., Ufer, S., Buck, R. P., Johnson, T. A., Dunlap, L. A., & Cascio, W. E. (1998) · Analytical Chemistry · doi:10.1021/ac980608e · Cited by 219 · cited 2×
“Iridium oxide was electrochemically deposited onto PtIr electrodes from solution using methods similar to those used in [9].”
BackgroundMethodA system for MEA-based multisite stimulation
Jimbo, Y., Kasai, N., Torimitsu, K., Tateno, T., & Robinson, H. P. C. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805470 · Cited by 214
Over-pulsing degrades activated iridium oxide films used for intracortical neural stimulation
Cogan, S. F., Guzelian, A. A., Agnew, W. F., Yuen, T. G. H., & McCreery, D. B. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.02.019 · Cited by 210 · cited 1×
“However, IrOx coatings show instability during long-term pulsing at 2–3 [16] and conductive polymer coatings may provide a suitable alternative.”
BackgroundNegi, S., Bhandari, R., Rieth, L., & Solzbacher, F. (2010) · Biomedical Materials · doi:10.1088/1748-6041/5/1/015007 · Cited by 201 · cited 6×
“It should be noted that the IrOx used in this work was electroplated and activated IrOx (AIROF) or sputtered IrOx (SIROF) might lead to different results.”
BackgroundInfluentialWilks, S. (2009) · Frontiers in Neuroengineering · doi:10.3389/neuro.16.007.2009 · Cited by 188 · cited 5×
“This agrees with the dramatic increase in charge storage capacity of PEDOT when measured using fast CV, reported in [ 22 ].”
BackgroundMethodResultInfluentialSelf-citationPrimate Reaching Cued by Multichannel Spatiotemporal Cortical Microstimulation
Fitzsimmons, N. A., Drake, W., Hanson, T. L., Lebedev, M. A., & Nicolelis, M. A. L. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.5297-06.2007 · Cited by 163 · cited 2×
“Small electrodes also permit selective stimulation of small populations of neurons and this might be essential for prosthetic applications [5].”
BackgroundCogan, S. F., Troyk, P. R., Ehrlich, J., & Plante, T. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851503 · Cited by 162 · cited 3×
“been reported for both IrOx [14], [22], [34] and PEDOT [19],”
BackgroundMethodResultMcGill, K. C., Cummins, K. L., Dorfman, L. J., Berlizot, B. B., Luetkemeyer, K., Nishimura, D. G., & Widrow, B. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.325019 · Cited by 143 · cited 1×
“Capacitive coupling of the voltage on the stimulating electrode to nearby recording channels is one of the causes of this artifact [ 37 ].”
BackgroundSputtered iridium oxide films (SIROFs) for low-impedance neural stimulation and recording electrodes
Cogan, S. F., Plante, T. D., & Ehrlich, J. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1404158 · Cited by 138 · cited 1×
“IrOx is considered a promising alternative and can be formed by electroplating iridium oxide [9], by electrochemical activation of iridium (AIROF) [8], [10], or by reactive sputtering in an oxidizing plasma (SIROF) [11]–[13].”
BackgroundElectrochemical polymerization and properties of PEDOT/S-EDOT on neural microelectrode arrays
Xiao, Y., Cui, X. T., & Martin, D. C. (2004) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2004.06.024 · Cited by 112 · cited 2×
“PEDOT coatings on electrodes lead to significant reduction in electrical impedance and increase in charge injection in vitro [18], [19].”
BackgroundMethodSelf-citationA system for neural recording and closed-loop intracortical microstimulation in awake rodents.
Venkatraman, S., Elkabany, K., Long, J. D., Yao, Y., & Carmena, J. M. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005944 · Cited by 96
Self-citationStability of poly(3,4‐ethylene dioxythiophene) materials intended for implants
Thaning, E. M., Asplund, M. L. M., Nyberg, T. A., Inganäs, O. W., & von Holst, H. (2010) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31597 · Cited by 92 · cited 3×
“Similar substrate dependent mechanical delamination of PEDOT has been reported in other studies [20], [31].”
BackgroundResultCogan, S. F., Troyk, P. R., Ehrlich, J., Gasbarro, C. M., & Plante, T. D. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/008 · Cited by 88 · cited 1×
“The charge-injection limit is defined [29] as the quantity of charge which polarizes the electrode interface to the potential for water reduction or oxidation.”
BackgroundPhosphene induction by microstimulation of macaque V1
Tehovnik, E. J., & Slocum, W. M. (2007) · Brain Research Reviews · doi:10.1016/j.brainresrev.2006.11.001 · Cited by 83 · cited 1×
“2109399 has shown great potential for auditory [1], [2], visual [3], [4], and somatosensory [5] prostheses.”
BackgroundChronic microstimulation in the feline ventral cochlear nucleus: physiologic and histologic effects
McCreery, D. B., Yuen, T. G. H., & Bullara, L. A. (2000) · Hearing Research · doi:10.1016/s0378-5955(00)00190-8 · Cited by 82 · cited 1×
“2109399 has shown great potential for auditory [1], [2], visual [3], [4], and somatosensory [5] prostheses.”
BackgroundMicrostimulation in auditory cortex provides a substrate for detailed behaviors
Otto, K. J., Rousche, P. J., & Kipke, D. R. (2005) · Hearing Research · doi:10.1016/j.heares.2005.08.004 · Cited by 75 · cited 1×
“2109399 has shown great potential for auditory [1], [2], visual [3], [4], and somatosensory [5] prostheses.”
BackgroundAn electronic stimulus artifact suppressor
Freeman, J. A. (1971) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(71)90188-x · Cited by 67 · cited 1×
“The long duration of stimulation artifacts produced by microstimulation on nearby recording electrodes is a well known problem and has been encountered by researchers for decades [ 35 ], [36].”
BackgroundCogan, S. F. (2006) · 2006 International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2006.259654 · Cited by 55 · cited 1×
“to glial scar formation around the electrodes [32] and the nature of the in vivo electrolyte [33].”
BackgroundEick, S. (2009) · Frontiers in Neuroengineering · doi:10.3389/neuro.16.016.2009 · Cited by 46
Behavioral modulation of stimulus-evoked oscillations in barrel cortex of alert rats
Venkatraman, S., & Carmena, J. M. (2009) · Frontiers in Integrative Neuroscience · doi:10.3389/neuro.07.010.2009 · Cited by 22
Self-citationPenetrating microelectrode arrays with low-impedance sputtered iridium oxide electrode coatings
Cogan, S. F., Ehrlich, J., Plante, T. D., & Wagenen, R. V. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5335359 · Cited by 12 · cited 1×
“SIROF shows even better performance with a charge injection limit of 8 at a pulse width of 1 ms [15].”
Background
Research works printed but not linked: 2
- 0, Standard Practice for Accelerated Aging of Ultra-High Molecular Weight Polyethylene after Gamma Irradiation in Air
- 0, Standard Guide for Accelerated Aging of Sterile Barrier Systems for Medical Devices
Cited by
The rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Lu, B., Yuk, H., Lin, S., Jian, N., Qu, K., Xu, J., & Zhao, X. (2019) · Nature Communications · doi:10.1038/s41467-019-09003-5 · Cited by 1,035
Electrically conductive polymers and composites for biomedical applications
Kaur, G., Adhikari, R., Cass, P., Bown, M., & Gunatillake, P. (2015) · RSC Advances · doi:10.1039/c5ra01851j · Cited by 836
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Metadata
- Authors
- Venkatraman, S., Hendricks, J., King, Z. A., Sereno, A. J., Richardson-Burns, S., Martin, D., & Carmena, J. M.
- Affiliations
- Qualcomm (United States) (US)
- University of Michigan (US)
- University of Delaware (US)
- University of California, Berkeley (US)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2011-06
- Volume
- 19
- Issue
- 3
- Pages
- 307-316
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2154453638
- Semantic Scholar
- 96d94eb9fafb6c12897a64e2988fae1ba6d9b7f3
- Cited by
- 319
- References
- 39
- Citations by year
- 2026: 16 · 2025: 22 · 2024: 14 · 2023: 30 · 2022: 28 · 2021: 24 · 2020: 35 · 2019: 24 · 2018: 24 · 2017: 27 · 2016: 16 · 2015: 20 · 2014: 12 · 2013: 14 · 2012: 11
- FWCI
- 5.16
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Keywords
- PEDOT, conducting polymers, neural microelectrodes, neurostimulation, neural recording, neural prostheses, charge injection limit, electrode impedance, chronic implantation, cortical implants, platinum-iridium electrodes, iridium oxide electrodes, signal-to-noise ratio, voltage cycling, accelerated aging
- MeSH terms
- Animals, Electric Stimulation, Electrodes, Electrodes, Implanted, Electronics, Female, Iridium, Microelectrodes, Neurons, Polymers, Prosthesis Design, Rats, Sprague-Dawley, Bridged Bicyclo Compounds, Heterocyclic, Rats, Neural Prostheses
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.