In Vitro and In Vivo Evaluation of PEDOT Microelectrodes for Neural Stimulation and Recording
The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Cortical neural prostheses require chronically implanted small-area microelectrode arrays that simultaneously record and stimulate neural activity. It is necessary to develop new materials with low interface impedance and large charge transfer capacity for this application and we explore the use of conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) for the same. We subjected PEDOT coated electrodes to voltage cycling between -0.6 and 0.8 V, 24 h continuous biphasic stimulation at 3 mC/cm² and accelerated aging for four weeks. Characterization was performed using cyclic voltammetry, electrochemical impedance spectroscopy, and voltage transient measurements. We found that PEDOT coated electrodes showed a charge injection limit 15 times higher than Platinum Iridium (PtIr) electrodes and electroplated Iridium Oxide (IrOx) electrodes when using constant current stimulation at zero voltage bias. In vivo chronic testing of microelectrode arrays implanted in rat cortex revealed that PEDOT coated electrodes show higher signal-to-noise recordings and superior charge injection compared to PtIr electrodes.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In the recent decade, various nanomaterials[301,345,534,535] and conductive polymers[536–538] have also made their way into implantable stimulation electrodes, which have higher charge injection capacity (1~15 mC cm−2) compared to conventional materials (Pt 0.05~0.15 mC cm−2, TiN 0.9 mC cm−2).[39]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [534]
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243 · cited 3×
“Many neuroprostheses applications require that the same electrodes also be used for single unit neural recording and this places stringent constraints on the maximum area of the electrodes (typically smaller than 4000 [7]).”
BackgroundElectrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 3×
“More complete models of the electrode interface have been presented elsewhere [6], [28].”
BackgroundResponse of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 2×
“to glial scar formation around the electrodes [32] and the nature of the in vivo electrolyte [33].”
BackgroundConducting‐Polymer Nanotubes for Controlled Drug Release
Abidian, M. R., Kim, D. ‐., & Martin, D. C. (2006) · Advanced Materials · doi:10.1002/adma.200501726 · Cited by 869
Self-citationConducting polymers for neural interfaces: Challenges in developing an effective long-term implant
Green, R. A., Lovell, N. H., Wallace, G. G., & Poole-Warren, L. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.047 · Cited by 691 · cited 1×
“PEDOT is an electrically conducting polymer which is being investigated for improving the long-term performance of microfabricated neural prosthetic devices [17].”
BackgroundSchmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672
Impedance Characterization and Modeling of Electrodes for Biomedical Applications
Franks, W., Schenker, I., Schmutz, P., & Hierlemann, A. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847523 · Cited by 659 · cited 1×
“A simple electrical model of the tissue-electrode interface (adopted from [27]) is shown in Fig.”
MethodLudwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638 · cited 3×
“However, previous results [21] agree with our observation that PEDOT coated electrodes show a small improvement in signal to noise ratio of recordings.”
BackgroundResultInfluentialSelf-citationCui, X., & Martin, D. C. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00448-3 · Cited by 573 · cited 3×
“PEDOT coatings on electrodes lead to significant reduction in electrical impedance and increase in charge injection in vitro [18], [19].”
BackgroundSelf-citationIn vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
Weiland, J. D., Anderson, D. J., & Humayun, M. S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805487 · Cited by 382 · cited 6×
“It should be noted that the IrOx used in this work was electroplated and activated IrOx (AIROF) or sputtered IrOx (SIROF) might lead to different results.”
BackgroundInfluential
Research works printed but not linked: 2
- 0, Standard Practice for Accelerated Aging of Ultra-High Molecular Weight Polyethylene after Gamma Irradiation in Air
- 0, Standard Guide for Accelerated Aging of Sterile Barrier Systems for Medical Devices
Cited by
Items 101–200 of 342
Electrochemical and biological performance of chronically stimulated conductive hydrogel electrodes
Dalrymple, A. N., Robles, U. A. A., Huynh, M., Nayagam, B. A., Green, R. A., Poole-Warren, L. A., Fallon, J. B., & Shepherd, R. K. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab7cfc · Cited by 58
“Conductive polymers (CPs) can be coated onto metal electrodes to improve the electrochemical properties of the neural interface (Green et al 2008, Wilks et al 2009, Venkatraman et al 2011).”
BackgroundLee, Y. J., Kim, H.-J., Do, S. H., Kang, J. Y., & Lee, S. H. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.06.169 · Cited by 54
Gold nanograin microelectrodes for neuroelectronic interfaces
Kim, R., Hong, N., & Nam, Y. (2012) · Biotechnology Journal · doi:10.1002/biot.201200219 · Cited by 54
Aqrawe, Z., Wright, B. E., Patel, N. D., Vyas, Y., Malmström, J., Montgomery, J. M., Williams, D. E., Travaš‐Sejdić, J., & Svirskis, D. M. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.10.099 · Cited by 55
Soft Printable Electrode Coating for Neural Interfaces
Michael, S., Fallegger, F., Pirondini, E., Roux, A., Bichat, A., Barraud, Q., Courtine, G., & Lacour, S. P. (2020) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c00401 · Cited by 54
Cutaneous Recording and Stimulation of Muscles Using Organic Electronic Textiles
Papaiordanidou, M., Takamatsu, S., Rezaei‐Mazinani, S., Lonjaret, T., Martin, A., & Ismailova, E. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600299 · Cited by 50
Bioelectronic Medicine: a multidisciplinary roadmap from biophysics to precision therapies
González‐González, M. A., Conde, S. V., Latorre, R., Thébault, S. C., Pratelli, M., Spitzer, N. C., Verkhratsky, A., Tremblay, M., Akçora, C. G., Hernandez-Reynoso, A. G., et al. (2024) · Frontiers in Integrative Neuroscience · doi:10.3389/fnint.2024.1321872 · Cited by 50
Polydopamine-doped conductive polymer microelectrodes for neural recording and stimulation
Kim, R., & Nam, Y. (2019) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108369 · Cited by 48
Wang, M., Ji, B., Gu, X., Tian, H., Kang, X., Yang, B. T., Wang, X., Chen, X., Li, C., & Liu, J. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.07.030 · Cited by 48
Brunton, E. K., Winther-Jensen, B., Wang, C., Yan, E. B., Hagh Gooie, S., Lowery, A. J., & Rajan, R. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00265 · Cited by 46
“Furthermore, as there is a large variability between methods of calculating charge injection limits between different research groups, it is important to compare the CIC of different electrodes under the same conditions (Venkatraman et al., 2011).”
BackgroundMethodTriple‐network‐based conductive polymer hydrogel for soft and elastic bioelectronic interfaces
Chen, Y., Chen, L., Geng, B., Chen, F., Yuan, Y., Li, D., Wang, Y., Jia, W., & Hu, W. (2023) · SmartMat · doi:10.1002/smm2.1229 · Cited by 47
Kim, J. H., Kim, S., Kim, G., & Yoon, M. (2020) · Macromolecular Bioscience · doi:10.1002/mabi.202000211 · Cited by 49
Conducting Polymer‐ECM Scaffolds for Human Neuronal Cell Differentiation
Barberio, C., Sáez, J., Withers, A. M., Nair, M., Tamagnini, F., & Owens, R. M. (2022) · Advanced Healthcare Materials · doi:10.1002/adhm.202200941 · Cited by 47
Improved Poly(3,4-Ethylenedioxythiophene) (PEDOT) for Neural Stimulation
Mandal, H. S., Kastee, J. S., McHail, D. G., Rubinson, J. F., Pancrazio, J. J., & Dumas, T. C. (2015) · Neuromodulation Technology at the Neural Interface · doi:10.1111/ner.12285 · Cited by 51
Electroactive biomimetic collagen-silver nanowire composite scaffolds
Wickham, A., Vagin, M. Y., Khalaf, H., Bertazzo, S., Hodder, P., Dånmark, S., Bengtsson, T., Altimiras, J., & Aili, D. (2016) · Nanoscale · doi:10.1039/c6nr02027e · Cited by 47
Is Graphene Shortening the Path toward Spinal Cord Regeneration?
Girão, A. F., Serrano, M. C., Completo, A., & Marques, P. A. A. P. (2022) · ACS Nano · doi:10.1021/acsnano.2c04756 · Cited by 45
State‐of‐the‐Art Electronic Materials for Thin Films in Bioelectronics
Gablech, I., & Głowacki, E. D. (2023) · Advanced Electronic Materials · doi:10.1002/aelm.202300258 · Cited by 45
Donut‐Shaped Stretchable Kirigami: Enabling Electronics to Integrate with the Deformable Muscle
Morikawa, Y., Yamagiwa, S., Sawahata, H., Numano, R., Koida, K., & Kawano, T. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900939 · Cited by 44
Nanostructured Coatings for Improved Charge Delivery to Neurons
Kozai, T. D. Y., Alba, N. A., Zhang, H., Kotov, N. A., Gaunt, R. A., & Cui, X. T. (2014) · Springer eBooks · doi:10.1007/978-1-4899-8038-0_4 · Cited by 48
“When applied to metal-based biopotential electrodes, CP coatings have produced substantial changes to their electrical characteristics, including reduced impedance, increased CSC, and increased charge injection limit [133, 181, 183–185, 198–202].”
BackgroundYin, P., Liu, Y., Xiao, L., & Zhang, C. (2021) · Polymers · doi:10.3390/polym13162834 · Cited by 42
Muguet, I., Maziz, A., Mathieu, F., Mazenq, L., & Larrieu, G. (2023) · Advanced Materials · doi:10.1002/adma.202302472 · Cited by 43
Bioelectronic Neural Interfaces: Improving Neuromodulation Through Organic Conductive Coatings
Duan, W., Robles, U. A. A., Poole-Warren, L. A., & Esrafilzadeh, D. (2023) · Advanced Science · doi:10.1002/advs.202306275 · Cited by 46
Flexible Microinterventional Sensors for Advanced Biosignal Monitoring
Liu, Y., Fan, P., Pan, Y., & Ping, J. F. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.5c00115 · Cited by 43
Poly(3,4-ethylenedioxythiophene) (PEDOT) Coatings for High-Quality Electromyography Recording
Rossetti, N., Luthra, P., Hagler, J., Lee, A. H. J., Bodart, C., Li, X., Ducharme, G., Soavi, F., Amilhon, B., & Cicoira, F. (2019) · ACS Applied Bio Materials · doi:10.1021/acsabm.9b00809 · Cited by 45
Vara, H., & Collazos-Castro, J. E. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b09594 · Cited by 44
Ledo, A., Lourenço, C. F., Laranjinha, J. A. N., Brett, C. M. A., Gerhardt, G. A., & Barbosa, R. M. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03772 · Cited by 44
Luo, Z., & Ker, M. (2018) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2018.2796381 · Cited by 42
“The effective loading impedance to the stimulator will significantly vary in vivo because of the locations, distances, and the implantation time of the electrodes [15]–[18].”
BackgroundRajnicek, A. M., Zhao, Z., Moral‐Vico, J., Cruz, A. M., McCaig, C., & Casañ-Pastor, N. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201800473 · Cited by 41
PEDOT:PSS—A Key Material for Bioelectronics
Ramirez, A., van der Laan, D. P., Shah, M. B., Wang, L., Zeglio, E., & Savva, A. (2025) · Advanced Science · doi:10.1002/advs.202513480 · Cited by 46
Niederhoffer, T., Vanhoestenberghe, A., & Lancashire, H. T. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acb084 · Cited by 38
Overcoming failure: improving acceptance and success of implanted neural interfaces
Dalrymple, A. N., Jones, S. T., Fallon, J. B., Shepherd, R. K., & Weber, D. J. (2025) · Bioelectronic Medicine · doi:10.1186/s42234-025-00168-7 · Cited by 44
“…neuromuscular stimulation devices (Smith et al. 1987), intracortical electrodes (Pat-rick et al. 2011; Street et al. 2018; Takmakov et al. 2015; Venkatraman et al. 2011), floating microelectrode arrays (Bredeson et al. 2013), cochlear electrodes (Dalrymple et al. 2019), and retinal prostheses…”
Enhanced spinal cord microstimulation using conducting polymer-coated carbon microfibers
Vara, H., & Collazos-Castro, J. E. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.03.037 · Cited by 40
Dalrymple, A. N., Huynh, M., Nayagam, B. A., Lee, C. D., Weiland, G. R., Petrossians, A., John, J., Whalen, J. J., Fallon, J. B., & Shepherd, R. K. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab933d · Cited by 42
“These challenges include evidence of delamination of the coating [17, 26, 29], and an increase in electrode impedance in vivo [15, 16, 30] attributed to the effects of the tissue encapsulation of the electrode dominating the impedance by reducing the exposed electrode surface area, thereby reducing the capacitance of…”
BackgroundCharacteristics of Transparent, PEDOT:PSS-Coated Indium-Tin-Oxide (ITO) Microelectrodes
Yang, W., Broski, A., Wu, J., Fan, Q. H., & Li, W. (2017) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2017.2785627 · Cited by 38
“PEDOT:PSS, as one of the most prevalent conducting polymers (CPs), has been demonstrated with many desirable properties for electrophysiological recording, including high biostability, outstanding biocompatibility, and simple utilization with low-cost spin-coating and ink-jet printing techniques [5], [6].”
Self-healing electrical bioadhesive interface for electrophysiology recording
Ma, H., Hou, J., Xiao, X., Wan, R., Ge, G., Zheng, W., Chen, C., Cao, J., Wang, J., Liu, C., et al. (2023) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2023.09.190 · Cited by 37
Small bioactive molecules as dual functional co-dopants for conducting polymers
Goding, J. A., Gilmour, A. D., Martens, P. J., Poole-Warren, L. A., & Green, R. A. (2015) · Journal of Materials Chemistry B · doi:10.1039/c5tb00384a · Cited by 39
CNT-Au nanocomposite deposition on gold microelectrodes for improved neural recordings
Kim, G. H., Kim, K., Nam, H., Shin, K., Choi, W., Shin, J. H., & Lim, G. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.04.142 · Cited by 37
Neurospheres on Patterned PEDOT:PSS Microelectrode Arrays Enhance Electrophysiology Recordings
Pas, J., Pitsalidis, C., Koutsouras, D. A., Quilichini, P., Santoro, F., Cui, B., Gallais, L., O'Connor, R. P., Malliaras, G. G., & Owens, R. M. (2017) · Advanced Biosystems · doi:10.1002/adbi.201700164 · Cited by 35
Intracortical Microelectrode Array Unit Yield under Chronic Conditions: A Comparative Evaluation
Usoro, J. O., Sturgill, B. S., Musselman, K. C., Capadona, J. R., & Pancrazio, J. J. (2021) · Micromachines · doi:10.3390/mi12080972 · Cited by 36
Semiconducting electrodes for neural interfacing: a review
Ahnood, A., Chambers, A., Gelmi, A. A., Yong, K., & Kavehei, O. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00830k · Cited by 36
Development of a conducting polymer cell impedance sensor
Karimullah, A. S., Cumming, D. R. S., Riehle, M. O., & Gadegaard, N. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.09.075 · Cited by 38
Kim, R., & Nam, Y. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/2/026010 · Cited by 38
“as iridium oxide [10] or conductive polymers [13, 44].”
BackgroundGradual Morphological Change in PEDOT:PSS Thin Films Immersed in an Aqueous Solution
Lee, I., Park, S., Lee, Y. S., Kim, Y., Kang, M. H., & Yun, C. (2023) · Langmuir · doi:10.1021/acs.langmuir.2c03038 · Cited by 34
High‐density implantable neural electrodes and chips for massive neural recordings
Wang, L., Suo, Y., Wang, J., Wang, X., Xue, K., An, J., Sun, X., Chen, Q., Tang, X., Zhao, Y., et al. (2024) · Brain‐X · doi:10.1002/brx2.65 · Cited by 36
Chik, G. K. K., Xiao, N., Ji, X., Tsang, A. C. O., Leung, G., Zhang, S., Tin, C., & Chan, P. K. L. (2022) · Advanced Materials Technologies · doi:10.1002/admt.202200143 · Cited by 35
Kashkoush, A. I., Gaunt, R. A., Fisher, L. E., Bruns, T. M., & Weber, D. J. (2019) · Scientific Reports · doi:10.1038/s41598-019-38924-w · Cited by 35
On the Way to Large-Scale and High-Resolution Brain-Chip Interfacing
Vassanelli, S., Mahmud, M., Girardi, S., & Maschietto, M. (2012) · Cognitive Computation · doi:10.1007/s12559-011-9121-4 · Cited by 33
“Though the recent development has seen some closed loop stimulation devices [24–26], yet, the integration of recording and stimulation sites at a higher— resolution still remains an open problem.”
BackgroundZhang, C., Driver, N., Tian, Q., Jiang, W., & Liu, H. H. (2018) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.36385 · Cited by 35
Micro/Nano Technologies for High-Density Retinal Implant
Zeng, Q., Zhao, S., Yang, H., Zhang, Y., & Wu, T. (2019) · Micromachines · doi:10.3390/mi10060419 · Cited by 36
“It had better electrochemical stability after stimulating with charge density up to 3 mC⋅cm−2, compared to IrOx coating [100].”
MethodWang, K.-P., Parekh, U., Ting, J., Yamamoto, N. A. D., Zhu, J. H., Costantini, T. W., Arias, A. C., Eliceiri, B. P., & Ng, T. N. (2019) · Advanced Biosystems · doi:10.1002/adbi.201900106 · Cited by 32
Advancements in Biological Neural Interfaces Using Conducting Polymers: A Review
Parashar, K., Prajapati, D. G., McIntyre, R., & Kandasubramanian, B. (2020) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.0c00174 · Cited by 32
Dalrymple, A. N., Huynh, M., Robles, U. A. A., Marroquin, J. B., Lee, C. D., Petrossians, A., Whalen, J. J., Li, D., Parkington, H. C., Forsythe, J. S., et al. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab5163 · Cited by 32
“…and a significant increase in charge injection capacity over conventional electrode materials such as Pt (Richardson et al 2009, Ludwig et al 2011, Venkatraman et al 2011, Hassarati et al 2014, Green and Abidian 2015, Zeng et al 2015, Bennett et al 2016, Ouyang et al 2017, Nimbalkar et al 2018).”
BackgroundPranti, A. S., Schander, A., Bödecker, A., & Lang, W. (2017) · EUROSENSORS Conference (EUROSENSORS) · doi:10.3390/proceedings1040492 · Cited by 33
“Introduction Miniaturization and high charge injection capacity of neural interfaces electrodes are the paramount preconditions for successful stimulation and recording signal from specific target cell [1].”
BackgroundMurbach, J. M., Currlin, S., Widener, A. E., Tong, Y., Chhatre, S. S., Subramanian, V., Martin, D. C., Johnson, B. N., & Otto, K. J. (2018) · MRS Communications · doi:10.1557/mrc.2018.138 · Cited by 33
Self-citationSrivastava, S. B., Melikov, R., Aria, M. M., Dikbas, U. M., Kavaklı, İ. H., & Nizamoğlu, S. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.11.044012 · Cited by 31
Flexible IrOx neural electrode for mouse vagus nerve stimulation
Sun, T., Tsaava, T., Peragine, J., Crosfield, C., Lopez, M. F., Modi, R., Sharma, R., Li, C., Sohal, H. S., Chang, E. H., et al. (2023) · Acta Biomaterialia · doi:10.1016/j.actbio.2023.01.026 · Cited by 31
Stimulation and Recording Electrodes for Neural Prostheses
Aryan, N. P., Kaim, H., & Rothermel, A. (2014) · Springer briefs in electrical and computer engineering · doi:10.1007/978-3-319-10052-4 · Cited by 34
Engineering Smart Hybrid Tissues with Built-In Electronics
Feiner, R., & Dvir, T. (2020) · iScience · doi:10.1016/j.isci.2020.100833 · Cited by 33
Mechanically robust, photopatternable conductive hydrogel composites
Pal, R. K., Turner, E. E., Chalfant, B. H., & Yadavalli, V. K. (2017) · Reactive and Functional Polymers · doi:10.1016/j.reactfunctpolym.2017.09.006 · Cited by 32
Materials considerations of implantable neuroengineering devices for clinical use
Merrill, D. R. (2014) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2014.07.002 · Cited by 29
PEDOT Electrochemical Polymerization Improves Electrode Fidelity and Sensitivity
Frost, C. M., Wei, B. P. C., Baghmanli, Z., Cederna, P. S., & Urbanchek, M. G. (2012) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0b013e31824422bf · Cited by 31
Design of Dual-Mode Stimulus Chip With Built-In High Voltage Generator for Biomedical Applications
Yen, T.-Y., & Ker, M. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2999398 · Cited by 28
“time of the electronic device [17], [18].”
Potential therapeutic strategies for photoreceptor degeneration: the path to restore vision
Karamali, F., Behtaj, S., Abraki, S. B., Hadady, H., Atefi, A., Savoj, S., Soroushzadeh, S., Najafian, S., Nasr‐Esfahani, M. H., & Klassen, H. J. (2022) · Journal of Translational Medicine · doi:10.1186/s12967-022-03738-4 · Cited by 27
Implantable neural electrodes: from preparation optimization to application
Zhang, B., Xie, R., Jiang, J., Hao, S., Fang, B., Zhang, J., Bai, H., Peng, B., Li, L., Liu, Z., et al. (2023) · Journal of Materials Chemistry C · doi:10.1039/d2tc05162a · Cited by 28
Recent Advancements in Graphene-Based Implantable Electrodes for Neural Recording/Stimulation
Alahi, M. E. E., Rizu, M. I., Tina, F. W., Huang, Z., Nag, A., & Afsarimanesh, N. (2023) · Sensors · doi:10.3390/s23249911 · Cited by 30
“Secondly, the interface may generate harmful toxic ingredients, which can enhance the immune Secondly, the interface may generate harmful toxic ingredients, which can enhance the immune response or lead to the death of neural cells. response or lead to the death of neural cells.”
BackgroundSui, L., Song, X., Ren, J., Cai, W., Ju, L. H., Wang, Y., Wang, L. Y., & Chen, M. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34837 · Cited by 28
Ordek, G., Groth, J. D., & Şahin, M. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00455.2012 · Cited by 28
“In this study, we recorded spontaneous and evoked potentials from the cerebellar surface with chronically implanted, flexible-substrate, multielectrode arrays in rats and compared them to the signals simultaneously recorded from the motor cortex with similar electrodes.”
MethodFunctional plasma-polymerized hydrogel coatings for electrochemical biosensing
Levien, M., Farka, Z., Pastucha, M., Skládal, P., Nasri, Z., Weltmann, K., & Fricke, K. (2022) · Applied Surface Science · doi:10.1016/j.apsusc.2022.152511 · Cited by 26
Implantable electrode array with platinum black coating for brain stimulation in fish
Zhang, C., Liu, J., Tian, H., Kang, X., Du, J., Rui, Y.-F., Yang, B. T., & Yang, C. (2013) · Microsystem Technologies · doi:10.1007/s00542-013-2017-3 · Cited by 25
Electrochemical Principles of Safe Charge Injection
Cogan, S. F., Garrett, D. J., & Green, R. A. (2016) · Wiley eBooks · doi:10.1002/9781118816028.ch3 · Cited by 27
Duc, D., Stoddart, P. R., McArthur, S. L., Kapsa, R. M. I., Quigley, A. F., Boyd‐Moss, M., & Moulton, S. E. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801321 · Cited by 25
Nanoscale-Tipped High-Aspect-Ratio Vertical Microneedle Electrodes for Intracellular Recordings
Kubota, Y., Oi, H., Sawahata, H., Goryu, A., Ando, Y., Numano, R., Ishida, M., & Kawano, T. (2016) · Small · doi:10.1002/smll.201600172 · Cited by 24
Kitto, T., Bodart, C., Rossetti, N., & Cicoira, F. (2019) · Elsevier eBooks · doi:10.1016/b978-0-08-102284-9.00025-5 · Cited by 24
Liu, K., Zhang, H., Hu, M., Li, Z., Xu, K., Chen, D., Cui, W., Lv, C., Ding, R., Geng, X., et al. (2024) · Materials Advances · doi:10.1039/d3ma01105d · Cited by 26
Teixeira, H., Dias, C., Veloso, R. C., Apolinário, A., & Ventura, J. O. (2022) · Progress in Organic Coatings · doi:10.1016/j.porgcoat.2022.106894 · Cited by 23
Cai, Y., Tu, T., Li, T., Zhang, S., Zhang, B., Lü, F., Ye, X., & Liang, B. (2022) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2022.116738 · Cited by 23
Meijs, S., Alcaide, M. L., Sørensen, C., McDonald, M. G., Sørensen, S. S., Rechendorff, K., Gerhardt, A., Nesládek, M., Rijkhoff, N., & Pennisi, C. P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/5/056011 · Cited by 26
Magnesium-based biodegradable microelectrodes for neural recording
Zhang, C., Wen, T. H., Razak, K. A., Lin, J., Xu, C., Seo, C., Villafana, E., Jiménez, H. O. T., & Liu, H. H. (2020) · Materials Science and Engineering C · doi:10.1016/j.msec.2019.110614 · Cited by 23
Transient neurovascular interface for minimally invasive neural recording and stimulation
Fanelli, A., Ferlauto, L., Zollinger, E. G., Brina, O., Reymond, P., Machi, P., & Ghezzi, D. (2022) · Advanced Materials Technologies · doi:10.1002/admt.202100176 · Cited by 22
Flexible, ultrathin bioelectronic materials and devices for chronically stable neural interfaces
Zhou, L., Wu, Z., Sun, M., Park, J., Han, M., Wang, M., Yu, J., Di, Z., Mei, Y., Bai, W., et al. (2023) · Brain‐X · doi:10.1002/brx2.47 · Cited by 29
Hejazi, M. A., Tong, W., Stacey, A. D., Sun, S. H., Yunzab, M., Almasi, A., Jung, Y. J., Hamish Meffin, A., Fox, K. E., Edalati, K., et al. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202006101 · Cited by 22
Aghdam, T. S., Alavi, S. M. M., & Saif, M. (2022) · Automatica · doi:10.1016/j.automatica.2022.110463 · Cited by 21
Long nanoneedle-electrode devices for extracellular and intracellular recording in vivo
Kubota, Y., Yamagiwa, S., Sawahata, H., Idogawa, S., Tsuruhara, S., Numano, R., Koida, K., Ishida, M., & Kawano, T. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.11.152 · Cited by 21
Transparent, Low‐Impedance Inkjet‐Printed PEDOT:PSS Microelectrodes for Multimodal Neuroscience
Donaldson, P. D., & Swisher, S. L. (2022) · physica status solidi (a) · doi:10.1002/pssa.202100683 · Cited by 23
Electrodeposition of WO3 Nanoparticles for Sensing Applications
Santos, L., Neto, J. P., Crespo, A., Baião, P., Barquinha, P. M. C., Pereira, L., Martins, R., & Fortunato, E. M. C. (2015) · InTech eBooks · doi:10.5772/61216 · Cited by 24
Jurin, F. E., Buron, C. C., Frau, E., del Rossi, S., & Schintke, S. (2024) · Sensors · doi:10.3390/s24020570 · Cited by 20
Fabrication of Sodium Trimetaphosphate-Based PEDOT:PSS Conductive Hydrogels
Reynolds, M., Stoy, L. M., Sun, J., Amponsah, P. E. O., Li, L., Soto, M., & Song, S. (2024) · Gels · doi:10.3390/gels10020115 · Cited by 20
“Crosslinking with other highly biocompatible hydrogels can create interpenetrating conductive hydrogels, which mimic the elastic modulus of natural tissue [22,30–32] and exhibit cytocompatibility [33,34].”
BackgroundGuide to Leveraging Conducting Polymers and Hydrogels for Direct Current Stimulation
Leal, J., Shaner, S. W., Matter, L., Böhler, C., & Asplund, M. (2023) · Advanced Materials Interfaces · doi:10.1002/admi.202202041 · Cited by 22
Flexible multi-channel microelectrode with fluidic paths for intramuscular stimulation and recording
Tian, H., Liu, J., Kang, X., He, Q., Yang, B. T., Chen, X., & Yang, C. (2015) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2015.02.035 · Cited by 24
Sim, S., Shin, H., Bae, K., Han, H., Kang, Y., Woo, J., Cho, Y., Cho, I., & Kim, J. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.134124 · Cited by 19
Printable Poly(3,4-ethylenedioxythiophene)-Based Conductive Patches for Cardiac Tissue Remodeling
Luque, G. C., Picchio, M. L., Daou, B., Lasa-Fernández, H., Criado‐Gonzalez, M., Querejeta, R., Rama, D. F., Prato, M., Mecerreyes, D., Ruíz-Cabello, J., et al. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c03784 · Cited by 19
Q-PINE: A quick to implant peripheral intraneural electrode
Strauss, I., Niederhoffer, T., Giannotti, A., Panarese, A. M., Bernini, F., Gabisonia, K., Ottaviani, M. M., Petrini, F. M., Recchia, F. A., Raspopović, S., et al. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abc52a · Cited by 19
Woo, H., Kim, S., Nam, H., Choi, W., Shin, K., Kim, K., Yoon, S., Kim, G. H., Kim, J., & Lim, G. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c02168 · Cited by 19
Metal-Free Transparent Three-Dimensional Flexible Electronics by Selective Molecular Bridges
Chang, W.-S., Chang, T.-S., Wang, C., & Liao, W. (2022) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c20931 · Cited by 21
Sodium Dodecyl Sulfate doping PEDOT to enhance the performance of neural microelectrode
Wu, X. M., Pei, W., Zhang, H., Chen, Y., Guo, X., Chen, H., & Wang, S. (2015) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2015.10.005 · Cited by 20
Polymer Bioelectronics: A Solution for Both Stimulating and Recording Electrodes
Cuttaz, E. A., Bailey, Z., Chapman, C. A. R., Goding, J. A., & Green, R. A. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202304447 · Cited by 20
Saunier, V., Emmanuel Flahaut, B., Blatché, M.-C., Bergaud, C., & Maziz, A. (2020) · MethodsX · doi:10.1016/j.mex.2020.101106 · Cited by 18
Qu, J. K., Garabedian, N., Burris, D. L., & Martin, D. C. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.103376 · Cited by 19
Self-citationSchander, A., Stemmann, H., Kreiter, A. K., & Lang, W. (2018) · Micromachines · doi:10.3390/mi9030131 · Cited by 18
Electrodeposited PEDOT:BF 4 Coatings Improve Impedance of Chronic Neural Stimulating Probes In Vivo
Hagler, J., Yeu, J., Zhou, X., Ducharme, G., Amilhon, B., & Cicoira, F. (2022) · Advanced Materials Interfaces · doi:10.1002/admi.202201066 · Cited by 19
Metadata
- Authors
- Venkatraman, S., Hendricks, J., King, Z. A., Sereno, A. J., Richardson-Burns, S., Martin, D., & Carmena, J. M.
- Affiliations
- Qualcomm (United States) (US)
- University of Michigan (US)
- University of Delaware (US)
- University of California, Berkeley (US)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2011-06
- Volume
- 19
- Issue
- 3
- Pages
- 307-316
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2154453638
- Semantic Scholar
- 96d94eb9fafb6c12897a64e2988fae1ba6d9b7f3
- Cited by
- 319
- References
- 39
- Citations by year
- 2026: 16 · 2025: 22 · 2024: 14 · 2023: 30 · 2022: 28 · 2021: 24 · 2020: 35 · 2019: 24 · 2018: 24 · 2017: 27 · 2016: 16 · 2015: 20 · 2014: 12 · 2013: 14 · 2012: 11
- FWCI
- 5.16
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Keywords
- PEDOT, conducting polymers, neural microelectrodes, neurostimulation, neural recording, neural prostheses, charge injection limit, electrode impedance, chronic implantation, cortical implants, platinum-iridium electrodes, iridium oxide electrodes, signal-to-noise ratio, voltage cycling, accelerated aging
- MeSH terms
- Animals, Electric Stimulation, Electrodes, Electrodes, Implanted, Electronics, Female, Iridium, Microelectrodes, Neurons, Polymers, Prosthesis Design, Rats, Sprague-Dawley, Bridged Bicyclo Compounds, Heterocyclic, Rats, Neural Prostheses
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.