Resolving the Limb Position Effect in Myoelectric Pattern Recognition
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Reported studies on pattern recognition of electromyograms (EMG) for the control of prosthetic devices traditionally focus on classification accuracy of signals recorded in a laboratory. The difference between the constrained nature in which such data are often collected and the unpredictable nature of prosthetic use is an example of the semantic gap between research findings and a viable clinical implementation. In this paper, we demonstrate that the variations in limb position associated with normal use can have a substantial impact on the robustness of EMG pattern recognition, as illustrated by an increase in average classification error from 3.8% to 18%. We propose to solve this problem by: 1) collecting EMG data and training the classifier in multiple limb positions and by 2) measuring the limb position with accelerometers. Applying these two methods to data from ten normally limbed subjects, we reduce the average classification error from 18% to 5.7% and 5.0%, respectively. Our study shows how sensor fusion (using EMG and accelerometers) may be an efficient method to mitigate the effect of limb position and improve classification accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Use of Ranks in One-Criterion Variance Analysis
Kruskal, W. H., & Wallis, W. A. (1952) · Journal of the American Statistical Association · doi:10.1080/01621459.1952.10483441 · Cited by 13,912 · cited 1×
“The median classification errors of the two groups are significantly different ( ) according to the Kruskal-Wallis test [18], [20].”
MethodFundamentals of Biostatistics.
(1969) · Annals of Internal Medicine · doi:10.7326/0003-4819-70-4-873 · Cited by 4,575
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743 · cited 2×
“Englehart and Hudgins [1] showed that simple time-domain (TD) feature extraction combined with a linear discriminant analysis (LDA) classifier can be used as an effective real-time control scheme for myoelectric control.”
BackgroundMethodSelf-citationTargeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089 · cited 1×
“[23] introduced alternative quantitative usability metrics focused on class selection and motion completion times.”
BackgroundMyoelectric signal processing for control of powered limb prostheses
Parker, P., Englehart, K., & Hudgins, B. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.08.006 · Cited by 651
Self-citationHuang, Y., Englehart, K. B., Hudgins, B., & Chan, A. D. C. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856295 · Cited by 643
Self-citationRao, K. J. P. H., Janardhan, K., & Rao, P. (2010) · Cited by 559
Jiang, N., Englehart, K. B., & Parker, P. A. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2007967 · Cited by 450
Self-citationContinuous Myoelectric Control for Powered Prostheses Using Hidden Markov Models
Chan, A. D. C., & Englehart, K. B. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.836492 · Cited by 343
Self-citationHargrove, L., Englehart, K., & Hudgins, B. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.11.005 · Cited by 276
Self-citationEMG Pattern Analysis and Classification for a Prosthetic Arm
Saridis, G. N., & Gootee, T. P. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324954 · Cited by 236
Examining the adverse effects of limb position on pattern recognition based myoelectric control
Scheme, E., Fougner, A., Stavdahl, Ø., Chan, A. D. C., & Englehart, K. (2010) · 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology · doi:10.1109/iembs.2010.5627638 · Cited by 161
Self-citationHoward, J., Hoit, J. D., Enoka, R. M., & Hasan, Z. (1986) · Experimental Brain Research · doi:10.1007/bf00237416 · Cited by 151
Hargrove, L., Losier, Y., Lock, B., Englehart, K., & Hudgins, B. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4353424 · Cited by 150
Self-citationA Combined sEMG and Accelerometer System for Monitoring Functional Activity in Stroke
Roy, S. H., Cheng, M. S., Chang, S.-S., Moore, J., De Luca, G., Nawab, S. H., & De Luca, C. J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2036615 · Cited by 135
Kang, W.-J., Shiu, J.-R., Cheng, C.-K., Lai, J.-S., Tsao, H.-W., & Kuo, T.-S. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.398638 · Cited by 118
Automatic recognition of sign language subwords based on portable accelerometer and EMG sensors
Li, Y., Chen, X. '., Tian, J., Zhang, X., Wang, K., & Yang, J. (2010) · INTERNATIONAL CONFERENCE ON MULTIMODAL INTERACTION · doi:10.1145/1891903.1891926 · Cited by 83
Jamison, J. C., & Caldwell, G. E. (1993) · Journal of Neurophysiology · doi:10.1152/jn.1993.70.3.947 · Cited by 81
Learning to Control Opening and Closing a Myoelectric Hand
Bouwsema, H., van der Sluis, C. K., & Bongers, R. M. (2010) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2010.06.025 · Cited by 81
Hill, W., Stavdahl, Ø., Hermansson, L. N., Kyberd, P., Swanson, S., & Hubbard, S. (2009) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0b013e3181a1d2dc · Cited by 53
Self-citationFeature-based classification of myoelectric signals using artificial neural networks
Gallant, P. J., Morin, E. L., & Peppard, L. (1998) · Medical & Biological Engineering & Computing · doi:10.1007/bf02523219 · Cited by 52
Proportional Myoelectric Control of a Multifunction Upper-limb Prosthesis
Fougner, A. L. (2007) · NVA (Nasjonalt vitenarkiv) · Cited by 41
Self-citation
Cited by
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
EMG feature evaluation for improving myoelectric pattern recognition robustness
Phinyomark, A., Quaine, F., Charbonnier, S., Serviere, C., Tarpin-Bernard, F., & Laurillau, Y. (2013) · Expert Systems with Applications · doi:10.1016/j.eswa.2013.02.023 · Cited by 643
Control of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495
“3 is a multi-modal pattern recognition approach, where levels 1–5 are described by Fougner [31] and the dashed lines represent a possible implementation of layers 6–8.”
InfluentialSelf-citationLinear and Nonlinear Regression Techniques for Simultaneous and Proportional Myoelectric Control
Hahne, J. M., Biebmann, F., Jiang, N., Rehbaum, H., Farina, D., Meinecke, F. C., Muller, K.-R., & Parra, L. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305520 · Cited by 365
Al-Timemy, A. H., Khushaba, R. N., Bugmann, G., & Escudero, J. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2445634 · Cited by 336
Metadata
- Authors
- Fougner, A., Scheme, E., Chan, A. D. C., Englehart, K., & Stavdahl, Ø.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2011-12
- Volume
- 19
- Issue
- 6
- Pages
- 644-651
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W1991397260
- Cited by
- 402
- References
- 22
- FWCI
- 10.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.