Object Manipulation Improvements Due to Single Session Training Outweigh the Differences Among Stimulation Sites During Vibrotactile Feedback
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
Most hand prostheses do not provide intentional haptic feedback about movement performance; thus users must rely almost completely on visual feedback. This paper focuses on understanding the effects of learning and different stimulation sites when vibrotactile stimulation is used as the intentional haptic feedback. Eighteen unimpaired individuals participated in this study with a robotic interface to manipulate a virtual object with visual and vibrotactile feedback at four body sites (finger, arm, neck, and foot) presented in a random order. All participants showed improvements in object manipulation performance with the addition of vibrotactile feedback. Specifically, performance showed a strong learning effect across time, with learning transferring across different sites of vibrotactile stimulation. The effects of learning over the experiment overshadowed the effects of different stimulation sites. The addition of a cognitive task slowed participants and increased the subjective difficulty. User preference ratings showed no difference in their preference among vibrotactile stimulation sites. These findings indicate that the stimulation site may not be as critical as ensuring adequate training with vibrotactile feedback during object manipulation. Future research to identify improvements in vibrotactile-based feedback parameters with amputees is warranted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Interestingly, some sites might have an initial advantage in representing specific information, due to its naturalness; however, the advantage dissolves when users are given enough time to become familiar with less intuitive sites (Stepp & Matsuoka, 2011).”
From Augmented visual, auditory, haptic, and multimodal feedback in motor learning: A review (2013) · cites this paper as Stepp & Matsuoka, 2011
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Age differences in short-term retention of rapidly changing information.
Kirchner, W. K. (1958) · Journal of Experimental Psychology · doi:10.1037/h0043688 · Cited by 1,798 · cited 1×
“This test involved listening to random 16 digit strings and responding verbally by identifying any numbers repeated with only one intervening number [35].”
Four channels mediate the mechanical aspects of touch
Bolanowski, S. J., Gescheider, G. A., Verrillo, R. T., & Checkosky, C. M. (1988) · The Journal of the Acoustical Society of America · doi:10.1121/1.397184 · Cited by 937 · cited 1×
“This frequency is in a region of maximal sensitivity of two of the four psychophysical channels: P and NP II, associated with Pacinian Corpuscle (PC) and Slowly Adapting (SA) II afferent fibers [33].”
Electrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827 · cited 2×
“The foremost attraction being that the noninvasive nature of this approach would allow for immediate wide-scale implementation among users of prosthetic hands [13], [14].”
Limb Amputation and Limb Deficiency: Epidemiology and Recent Trends in the United States
DILLINGHAM, T. R., PEZZIN, L. E., & MACKENZIE, E. J. (2002) · Southern Medical Journal · doi:10.1097/00007611-200208000-00018 · Cited by 822 · cited 1×
“However, the most common causes of upper limb amputation are trauma and peripheral vascular disease, with the risk of amputation due to either cause increasing steadily with age [46].”
Vibrating insoles and balance control in elderly people
Priplata, A. A., Niemi, J. B., Harry, J. D., Lipsitz, L. A., & Collins, J. J. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14470-4 · Cited by 572 · cited 1×
“Vibrotactile stimulators could be easily administered and hidden using insoles [29].”
Consumer design priorities for upper limb prosthetics
Biddiss, E., Beaton, D., & Chau, T. (2007) · Disability and Rehabilitation: Assistive Technology · doi:10.1080/17483100701714733 · Cited by 519 · cited 1×
“2168981 have both been noted by users as top design priorities [1], [2].”
Flexible strategies for sensory integration during motor planning
Sober, S. J., & Sabes, P. N. (2005) · Nature Neuroscience · doi:10.1038/nn1427 · Cited by 480 · cited 1×
“, [36] and [37]), and that cross-modal transfer (CMT) can occur during”
Multisensory Integration during Motor Planning
Sober, S. J., & Sabes, P. N. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-18-06982.2003 · Cited by 430 · cited 1×
“, [36] and [37]), and that cross-modal transfer (CMT) can occur during”
Biomimetic tactile sensor array
Wettels, N., Santos, V. J., Johansson, R. S., & Loeb, G. E. (2008) · Advanced Robotics · doi:10.1163/156855308x314533 · Cited by 348 · cited 1×
“There is currently technology to detect contact force on prosthetic hands and fingers during object manipulation [6–12], with many groups successfully integrating these technologies into prosthetic hands, e.”
Upper limb amputees can be induced to experience a rubber hand as their own
Ehrsson, H. H., Rosen, B., Stockselius, A., Ragno, C., Kohler, P., & Lundborg, G. (2008) · Brain · doi:10.1093/brain/awn297 · Cited by 343 · cited 1×
“The addition of haptic feedback to prostheses may encourage self-attribution of the body part [3], and based on studies in unimpaired individuals, may aid in object manipulation (e.”
Design of a cybernetic hand for perception and action
Carrozza, M. C., Cappiello, G., Micera, S., Edin, B. B., Beccai, L., & Cipriani, C. (2006) · Biological Cybernetics · doi:10.1007/s00422-006-0124-2 · Cited by 341 · cited 1×
“There is currently technology to detect contact force on prosthetic hands and fingers during object manipulation [6]–[12], with many groups successfully integrating these technologies into prosthetic hands, e.g., the cybernetic hand [8], [9].”
Zollo, L., Roccella, S., Guglielmelli, E., Carrozza, M. C., & Dario, P. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2007.901936 · Cited by 335 · cited 1×
“There is currently technology to detect contact force on prosthetic hands and fingers during object manipulation [6]–[12], with many groups successfully integrating these technologies into prosthetic hands, e.g., the cybernetic hand [8], [9].”
Ptito, M. (2005) · Brain · doi:10.1093/brain/awh380 · Cited by 310 · cited 1×
“Training using a cross-modality sensory substitution paradigm (electrotactile stimulation for visual perception) has shown improvements in perceptual task performance and changes in brain activation with 7 hours of training applied over 7 days [41].”
Results of an internet survey of myoelectric prosthetic hand users
Pylatiuk, C., Schulz, S., & Döderlein, L. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640601061265 · Cited by 257 · cited 1×
“2168981 have both been noted by users as top design priorities [1], [2].”
Vibrotactile Frequency Discrimination in Human Hairy Skin
Mahns, D. A., Perkins, N. M., Sahai, V., Robinson, L., & Rowe, M. J. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00483.2005 · Cited by 231 · cited 1×
“It is well known that humans have less subjective capacity for vibrotactile detection in the nonglabrous (hairy) skin than in glabrous skin [25].”
The benefit of force feedback in surgery: Examination of blunt dissection
Wagner, C. R., Stylopoulos, N., Jackson, P. G., & Howe, R. D. (2007) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.16.3.252 · Cited by 169 · cited 1×
“It has been suggested that in addition to the increased naturalness of direct haptic feedback, that it provides physical constraints that could aid in task performance relative to force feedback provided via sensory substitution [43].”
Design and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands
Pylatiuk, C., Kargov, A., & Schulz, S. (2006) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-200604000-00007 · Cited by 156 · cited 4×
“[7] asked five users of myoelectric prosthetic hands to perform a simple object grasp task both with and without vibrotactile feedback relating to the contact force with the object.”
InfluentialPatterson, P. E., & Katz, J. A. (1992) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.1992.01.0001 · Cited by 147 · cited 3×
“Previous work in this area has been crucial in providing directions for future research, but has also often been limited by small subject numbers, lack of objective goal performance measures (task performance with typical sensory feedback), and examination of limited areas of vibrotactile stimulation [7], [21], [23],…”
Verrillo, R. T. (1992) · Music Perception · doi:10.2307/40285553 · Cited by 135 · cited 1×
“A 250-Hz carrier frequency was used, because human glabrous skin has been shown to be maximally sensitive to vibrotactile stimulation at this frequency [31], [32].”
Haptic interaction in robot‐assisted endoscopic surgery: a sensorized end‐effector
Tavakoli, M., Patel, R. V., & Moallem, M. (2005) · The International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.16 · Cited by 132 · cited 1×
“These findings are similar to the previous work indicating that more natural haptic feedback during robotic surgery leads to shorter task times than feedback supplied through sensory substitution (augmented visual feedback about force interactions), due to the increase in the necessary cognitive processing by users [4…”
Effects of aging on vibration detection thresholds at various body regions
Stuart, M., Turman, A. B., Shaw, J., Walsh, N., & Nguyen, V. (2003) · BMC Geriatrics · doi:10.1186/1471-2318-3-1 · Cited by 126 · cited 2×
“Unfortunately, previous work has shown an increase in vibrotactile detection thresholds as a function of age [26], [34], [47], [48].”
On the Vibrational Sensitivity in Different Regions of the Body Surface
WILSKA, A. (1954) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1954.tb01139.x · Cited by 124 · cited 5×
“skin and has been shown to have lower vibrotactile detection thresholds than the upper arm [27], [28].”
InfluentialControl of a Six Degree of Freedom Prosthetic Arm After Targeted Muscle Reinnervation Surgery
Miller, L. A., Lipschutz, R. D., Stubblefield, K. A., Lock, B. A., Huang, H., Williams, T. W., Weir, R. F., & Kuiken, T. A. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2008.05.016 · Cited by 119 · cited 1×
“ulating a disposable plastic cup [30]).”
Testing a Prosthetic Haptic Feedback Simulator With an Interactive Force Matching Task
Chatterjee, A., Chaubey, P., Martin, J., & Thakor, N. (2008) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/01.jpo.0000311041.61628.be · Cited by 111 · cited 5×
“[21] presented eight unimpaired individuals with vibrotactile stimulation on the upper arm during use of a myoelectric prosthesis simulator to complete an interactive force-matching task.”
InfluentialForce Feedback Benefit Depends on Experience in Multiple Degree of Freedom Robotic Surgery Task
Wagner, C. R., & Howe, R. D. (2007) · IEEE Transactions on Robotics · doi:10.1109/tro.2007.904891 · Cited by 111 · cited 1×
“In addition, even with direct haptic feedback, only highly trained individuals improve performance without a significant increase in trial time [44].”
Kinesthetic Sensing for the EMG Controlled "Boston Arm"
Mann, R., & Reimers, S. (1970) · IEEE Transactions on Man Machine Systems · doi:10.1109/tmms.1970.299971 · Cited by 108 · cited 4×
“In a case study utilizing the Boston Arm in 1970, Mann and Reimers used vibrotactile stimulation on the participant’s stump to signal tactual display of limb angle, combined with force feedback at the stump during an arm positioning task [23].”
InfluentialTime-Course of Vibratory Adaptation and Recovery in Cutaneous Mechanoreceptive Afferents
Leung, Y. Y., Bensmaïa, S. J., Hsiao, S. S., & Johnson, K. O. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00001.2005 · Cited by 107
Vibrotactile thresholds at the fingertip, volar forearm, large toe, and heel
Morioka, M., Whitehouse, D. J., & Griffin, M. J. (2008) · Somatosensory & Motor Research · doi:10.1080/08990220802045574 · Cited by 106 · cited 1×
“skin and has been shown to have lower vibrotactile detection thresholds than the upper arm [27], [28].”
Sensory-feedback system compatible with myoelectric control
Scott, R. N., Brittain, R. H., Caldwell, R. R., Cameron, A. B., & Dunfield, V. A. (1980) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442481 · Cited by 104 · cited 1×
“A variety of both invasive and non-invasive approaches of sensory substitution have been suggested, such as vibrotactile, electrocutaneous, acoustic, and direct nerve stimulation [13–20].”
On the Design of Miniature Haptic Devices for Upper Extremity Prosthetics
Kim, K., Colgate, J. E., Santos-Munne, J. J., Makhlin, A., & Peshkin, M. A. (2010) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2009.2013944 · Cited by 100 · cited 1×
“There is currently technology to detect contact force on prosthetic hands and fingers during object manipulation [6]–[12], with many groups successfully integrating these technologies into prosthetic hands, e.”
Riso, R. R. (1999) · Technology and Health Care · doi:10.3233/thc-1999-7604 · Cited by 98 · cited 1×
“A variety of both invasive and non-invasive approaches of sensory substitution have been suggested, such as vibrotactile, electrocutaneous, acoustic, and direct nerve stimulation [13–20].”
Regional Variation and Changes With Ageing in Vibrotactile Sensitivity in the Human Footsole
Wells, C., Ward, L. M., Chua, R., & Inglis, J. T. (2003) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/58.8.b680 · Cited by 97 · cited 2×
“Unfortunately, previous work has shown an increase in vibrotactile detection thresholds as a function of age [26], [34], [47], [48].”
A comparison of alternative means of providing sensory feedback on upper limb prostheses
Shannon, G. F. (1976) · Medical & Biological Engineering & Computing · doi:10.1007/bf02478123 · Cited by 93 · cited 1×
“The foremost attraction being that the noninvasive nature of this approach would allow for immediate wide-scale implementation among users of prosthetic hands [13], [14].”
A myoelectrically-controlled prosthesis with sensory feedback
Shannon, G. F. (1979) · Medical & Biological Engineering & Computing · doi:10.1007/bf02440956 · Cited by 92 · cited 1×
“A variety of both invasive and non-invasive approaches of sensory substitution have been suggested, such as vibrotactile, electrocutaneous, acoustic, and direct nerve stimulation [13–20].”
Effect of aging on the subjective magnitude of vibration
Verrillo, R. T., Bolanowski, S. J., & Gescheider, G. A. (2002) · Somatosensory & Motor Research · doi:10.1080/0899022021000009161 · Cited by 87 · cited 1×
“Unfortunately, previous work has shown an increase in vibrotactile detection thresholds as a function of age [26], [34], [47], [48].”
A low-cost instrumented glove for monitoring forces during object manipulation
Castro, M. C. F., & Cliquet, A. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.593280 · Cited by 75 · cited 1×
“There is currently technology to detect contact force on prosthetic hands and fingers during object manipulation [6–12], with many groups successfully integrating these technologies into prosthetic hands, e.”
Visual and Haptic Feedback Contribute to Tuning and Online Control During Object Manipulation
Huang, F. C., Gillespie, R. B., & Kuo, A. D. (2007) · Journal of Motor Behavior · doi:10.3200/jmbr.39.3.179-193 · Cited by 71 · cited 1×
“, [4] and [5]), providing force feedback through noninvasive sensory substitution such as vibrotactile stimulation [7], [21]–[23] is a particularly inviting approach.”
Obstacle avoidance during human walking: learning rate and cross‐modal transfer
Erni, T., & Dietz, V. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.00303.x · Cited by 66 · cited 1×
“CMT has been studied in humans by Erni and Dietz, who found significant CMT between auditory to somatosensory feedback conditions during a lower limb motor learning task [38].”
Correlates of vibrotactile thresholds in men of different ages
Era, P., Jokela, J., Suominen, H., & Heikkinen, E. (1986) · Acta Neurologica Scandinavica · doi:10.1111/j.1600-0404.1986.tb07857.x · Cited by 57 · cited 1×
“Unfortunately, previous work has shown an increase in vibrotactile detection thresholds as a function of age [26], [34], [47], [48].”
Thick-film force, slip and temperature sensors for a prosthetic hand
Cranny, A., Cotton, D. P. J., Chappell, P. H., Beeby, S., & White, N. M. (2005) · Measurement Science and Technology · doi:10.1088/0957-0233/16/4/005 · Cited by 50 · cited 1×
“There is currently technology to detect contact force on prosthetic hands and fingers during object manipulation [6]–[12], with many groups successfully integrating these technologies into prosthetic hands, e.”
Stepp, C. E., & Matsuoka, Y. (2010) · 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology · doi:10.1109/iembs.2010.5626120 · Cited by 42 · cited 5×
“Although the addition of a cognitive task did not have an effect on box displacements, it led to decreased velocities and increased difficulty ratings, agreeing with previous work [22].”
InfluentialSelf-citationSubjective Magnitude Functions for Vibrotaction
Verrillo, R. T. (1970) · IEEE Transactions on Man Machine Systems · doi:10.1109/tmms.1970.299956 · Cited by 41 · cited 1×
“A 250-Hz carrier frequency was used, because human glabrous skin has been shown to be maximally sensitive to vibrotactile stimulation at this frequency [31], [32].”
The importance of information feedback in prostheses for the upper limbs/1
Schmidt, H. (1977) · Prosthetics and Orthotics International · doi:10.3109/03093647709164601 · Cited by 28 · cited 1×
“A variety of both invasive and non-invasive approaches of sensory substitution have been suggested, such as vibrotactile, electrocutaneous, acoustic, and direct nerve stimulation [13–20].”
Early use of artificial sensibility in hand transplantation
Lanzetta, M., Perani, D., Anchisi, D., Rosén, B., Danna, M., Scifo, P., Fazio, F., & Lundborg, G. (2004) · Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery · doi:10.1080/02844310310019860 · Cited by 27 · cited 1×
“A variety of both invasive and non-invasive approaches of sensory substitution have been suggested, such as vibrotactile, electrocutaneous, acoustic, and direct nerve stimulation [13–20].”
Temporal specificity in cross-modal transfer of the rabbit nictitating membrane response.
Kehoe, E. J., & Napier, R. M. (1991) · Journal of Experimental Psychology Animal Behavior Processes · doi:10.1037/0097-7403.17.1.26 · Cited by 26 · cited 1×
“Kehoe and Napier found that, in rabbits, CMT increases when the two stimuli share the same temporal pattern [39].”
Task performance with a dexterous teleoperated hand system
Howe, R. D., & Kontarinis, D. A. (1993) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.142109 · Cited by 23 · cited 1×
“, [4] and [5]), providing force feedback through noninvasive sensory substitution such as vibrotactile stimulation [7], [21]–[23] is a particularly inviting approach.”
Training Program for a Myo-Electrically Controlled Prosthesis with Sensory Feedback System
Agnew, P. J., & Shannon, G. F. (1981) · American Journal of Occupational Therapy · doi:10.5014/ajot.35.11.722 · Cited by 17 · cited 1×
“A variety of both invasive and non-invasive approaches of sensory substitution have been suggested, such as vibrotactile, electrocutaneous, acoustic, and direct nerve stimulation [13–20].”
Contextual effects on robotic experiments of sensory feedback for object manipulation
Stepp, C. E., Dellon, B., & Matsuoka, Y. (2010) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2010.5627824 · Cited by 9 · cited 2×
“Based on the previous work in our group [22], [45], the promise indicated by the findings of this study is tempered by”
Self-citationTran, T. D., & Delay, E. R. (1996) · Behavioural Brain Research · doi:10.1016/0166-4328(96)00008-3 · Cited by 5 · cited 1×
“CMT has been studied extensively in animal models and is defined as skills acquired during learning of a motor task with specific stimulus information being transferred to a new stimulus condition (e.g., [39] and [40]).”
Cited by
Augmented visual, auditory, haptic, and multimodal feedback in motor learning: A review
Sigrist, R., Rauter, G., Riener, R., & Wolf, P. (2013) · Psychonomic Bulletin & Review · doi:10.3758/s13423-012-0333-8 · Cited by 1,416
“Interestingly, some sites might have an initial advantage in representing specific information, due to its naturalness; however, the advantage dissolves when users are given enough time to become familiar with less intuitive sites (Stepp & Matsuoka, 2011).”
BackgroundHaptic wearables as sensory replacement, sensory augmentation and trainer – a review
Shull, P. B., & Damian, D. D. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0055-z · Cited by 245
“However, it may be that the location of skin stimulation is less important than other factors such as learning rates [55].”
BackgroundMarković, M., Schweisfurth, M. A., Engels, L. F., Bentz, T., Wüstefeld, D., Farina, D., & Dosen, S. S. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0371-1 · Cited by 148
“As demonstrated in previous studies, it seems that human subjects can flexibly integrate feedback delivered to different body locations [20, 42 – 44].”
BackgroundVirtual Grasping: Closed-Loop Force Control Using Electrotactile Feedback
Jorgovanovic, N., Dosen, S., Djozic, D. J., Krajoski, G., & Farina, D. (2014) · Computational and Mathematical Methods in Medicine · doi:10.1155/2014/120357 · Cited by 64
“, object manipulation rather than grasping) and for vibrotactile feedback [24], the training is very important for performance, even more than the actual stimulation setup [25].”
BackgroundRepeated Training with Augmentative Vibrotactile Feedback Increases Object Manipulation Performance
Stepp, C. E., An, Q., & Matsuoka, Y. (2012) · PLoS ONE · doi:10.1371/journal.pone.0032743 · Cited by 61
“neck, and foot), presented in a random order [25].”
BackgroundMethodResultSelf-citation
Metadata
- Authors
- Stepp, C. E., & Matsuoka, Y.
- Affiliations
- Boston University (US)
- University of Washington (US)
- ORCID
- Stepp, Cara E.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2011-12
- Volume
- 19
- Issue
- 6
- Pages
- 677-685
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- PMC
- PMC3401581
- OpenAlex
- W2032949631
- Cited by
- 28
- References
- 49
- Citations by year
- 2025: 1 · 2022: 1 · 2021: 4 · 2020: 2 · 2019: 3 · 2018: 2 · 2016: 1 · 2015: 5 · 2014: 3 · 2013: 2 · 2012: 4
- FWCI
- 1.46
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (T32HD007424)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Keywords
- vibrotactile feedback, haptic feedback, prosthetic hand, object manipulation, stimulation site, learning effects, single-session training, robotic interface, virtual object manipulation, cognitive task interference, user preferences, amputees
- MeSH terms
- Adult, Arm, Cognition, Female, Fingers, Foot, Humans, Learning, Male, Motor Skills, Neck, Physical Stimulation, Psychomotor Performance, Robotics, Software, Touch, User-Computer Interface, Vibration, Feedback, Physiological, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.