Electroencephalography (EEG)-Based Brain–Computer Interface (BCI): A 2-D Virtual Wheelchair Control Based on Event-Related Desynchronization/Synchronization and State Control
The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
This study aims to propose an effective and practical paradigm for a brain-computer interface (BCI)-based 2-D virtual wheelchair control. The paradigm was based on the multi-class discrimination of spatiotemporally distinguishable phenomenon of event-related desynchronization/synchronization (ERD/ERS) in electroencephalogram signals associated with motor execution/imagery of right/left hand movement. Comparing with traditional method using ERD only, where bilateral ERDs appear during left/right hand mental tasks, the 2-D control exhibited high accuracy within a short time, as incorporating ERS into the paradigm hypothetically enhanced the spatiotemoral feature contrast of ERS versus ERD. We also expected users to experience ease of control by including a noncontrol state. In this study, the control command was sent discretely whereas the virtual wheelchair was moving continuously. We tested five healthy subjects in a single visit with two sessions, i.e., motor execution and motor imagery. Each session included a 20 min calibration and two sets of games that were less than 30 min. Average target hit rate was as high as 98.4% with motor imagery. Every subject achieved 100% hit rate in the second set of wheelchair control games. The average time to hit a target 10 m away was about 59 s, with 39 s for the best set. The superior control performance in subjects without intensive BCI training suggested a practical wheelchair control paradigm for BCI users.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“EEG signals in BCIs are generally categorized into spontaneous EEG [73] and EPs [74].”
From IENet: a robust convolutional neural network for EEG based brain-computer interfaces (2022) · cites this paper as [74]
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“2190299 muscular conduction pathway in the human body [8].”
BackgroundEvent-related EEG/MEG synchronization and desynchronization: basic principles
Pfurtscheller, G., & Lopes da Silva, F. H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00141-8 · Cited by 7,328 · cited 1×
“nization (ERD) [17], a phenomenon of EEG amplitude attenua-”
BackgroundLearning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761 · cited 1×
“ESEARCH on Brain-computer Interfaces (BCIs) has approximately forty years during which time the potential of BCI applications has been explored in many fields, including: communication, robotics and mobility control, and neuroprosthetics [1-7].”
BackgroundCortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591 · cited 1×
“ESEARCH on Brain-computer Interfaces (BCIs) has approximately forty years during which time the potential of BCI applications has been explored in many fields, including: communication, robotics and mobility control, and neuroprosthetics [1-7].”
BackgroundA spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577 · cited 1×
“ESEARCH on Brain-computer Interfaces (BCIs) has approximately forty years during which time the potential of BCI applications has been explored in many fields, including: communication, robotics and mobility control, and neuroprosthetics [1-7].”
BackgroundControl of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512 · cited 1×
“discriminate control state ERD from non-control state baseline activity, users could achieve 1-D, 2-D cursor or wheelchair control [6, 18-23].”
BackgroundNunez, P. L., Srinivasan, R., Westdorp, A. F., Wijesinghe, R. S., Tucker, D. M., Silberstein, R. B., & Cadusch, P. J. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00066-7 · Cited by 1,225 · cited 1×
“SLD operation improves the localization of sources [39], enhance the EEG feature of local synchrony, i.”
BackgroundAn on-line transformation of EEG scalp potentials into orthogonal source derivations
Hjorth, B. (1975) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(75)90056-5 · Cited by 1,012 · cited 1×
“Surface Laplacian derivation (SLD) was applied as the spatial filter, where EEG signal from each electrode was referenced to the averaged potentials from the nearby four orthogonal electrodes [38].”
MethodROC Graphs: Notes and Practical Considerations for Data Mining Researchers
Fawcett, T. E. (2003) · Cited by 757
Noninvasive Brain-Actuated Control of a Mobile Robot by Human EEG
del R. Millan, J., Renkens, F., Mourino, J., & Gerstner, W. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827086 · Cited by 740
Cited by
Items 201–241 of 241
Penava, P., Brozat, M.-L., Zimmermann, Y., Breitenbach, J., Ulrich, P., & Buettner, R. (2023) · Hawaii International Conference on System Sciences (HICSS) · doi:10.24251/hicss.2023.496 · Cited by 2
Wang, J. (2014) · Tuwhera (Auckland University of Technology) · Cited by 3
Qin, Y., Xu, Q., Kujala, T., Wang, X., & Cong, F. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.109535 · Cited by 1
Iida, Y., & Horie, R. (2017) · IEEJ Transactions on Electronics Information and Systems · doi:10.1541/ieejeiss.137.595 · Cited by 1
EEG Signal Analysis Based Brain-Computer
Nooreldeen, H., Badawy, S. M., & El-Brawany, M. A. (2021) · Menoufia Journal of Electronic Engineering Research · doi:10.21608/mjeer.2021.193083 · Cited by 2
“EEG methods commonly executed for BCIs depend on activity of sensorimotor rhythms (SMR) measured during movement imagery and permit establishing sensorimotor rhythm-based BCI (SMR BCI)or motor-imagery BCI (MI BCI) [7]. experimentally MI-BCI can control devices like wheelchairs[8].”
MethodNoninvasive brain–computer interfaces using fNIRS, EEG, and hybrid EEG-fNIRS
Nazeer, H., Naseer, N., Khan, M. J., & Hong, K. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95439-6.00003-x · Cited by 1
EMG intention perception approach in multimodal human computer interaction of wheelchairs
Hong, J., Cai, M., & Qin, X. (2025) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2025.2560524 · Cited by 1
Aissa, N. E. H. S. B., Kerrache, C. A., & Calafate, C. T. (2026) · Computer Standards & Interfaces · doi:10.1016/j.csi.2026.104155 · Cited by 1
Idle Mode Detection for Somatosensory-Based Brain-Computer Interface
Shu, X., Yao, L., Sheng, X., Zhang, D., & Zhu, X. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-22879-2_27 · Cited by 2
“Compared with the work of Huang [14], our experiment is based on selective sensation which has been proved to be more robust than motor imagery.”
EEG-Based Condition Clustering using Self-Organising Neural Network Map
Hamdoun, H., & Usman, A. A. (2016) · Communications in computer and information science · doi:10.1007/978-3-319-44188-7_11 · Cited by 1
Development of efficient brain computer interface (BCI) system for stroke rehabilitation
Dilshad, A., & Uddin, V. (2014) · IEEE International Multitopic Conference (INMIC) · doi:10.1109/inmic.2014.7097357 · Cited by 1
Development of Intelligent Powerd Wheelchair
Kallam, R. M. R., & SHARMA, H. K. (2017) · IEEE International Advance Computing Conference · doi:10.1109/iacc.2017.0121 · Cited by 1
“Fewer designs use voice command received through a microphone to operate the wheelchair[10].”
BackgroundBCI based control of wheelchair for mobility
kohli, P., & Warhade, K. K. (2017) · International Journal of Engineering and Technology · doi:10.21817/ijet/2017/v9i4/170904102 · Cited by 1
Improvement of Motor Imagery BCI using Silent Speech
Ngamrassameewong, S., Manatchinapisit, V., & Wongsawat, Y. (2020) · International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON) · doi:10.1109/ecti-con49241.2020.9158081 · Cited by 1
“Thus, ERD and ERS in motor imagery technique can be implemented and used with assistive device system [2].”
MethodA Deep CNN System for Classification of Emotions Using EEG Signals
Heaton, J., & Givigi, S. N. (2022) · IEEE International Systems Conference (SysCon) · doi:10.1109/syscon53536.2022.9773832 · Cited by 1
Brain-Controlled Assistive Robotics and Prosthetics
Puthuveetil, K. P., & Krusienski, D. J. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-87865-4.00010-8 · Cited by 1
Multi-target-Based Cursor Movement in Brain-Computer Interface Using CLIQUE Clustering
Saurav, S. K., Chakladar, D. D., Shaw, P., Chakraborty, S., & Kairi, A. (2018) · Advances in intelligent systems and computing · doi:10.1007/978-981-13-1544-2_34 · Cited by 1
Thomas, N., & Ayaz, H. (2017) · iDEA - Drexel University Institutional Repository · doi:10.17918/etd-7458 · Cited by 2
Chan, R. W., Lubbe, R. H. J. V. D., Immink, M. A., & Verwey, W. B. (2023) · PsyArXiv (OSF Preprints) · doi:10.31234/osf.io/dhb9g · Cited by 1
Design and comparative evaluation of a BCI-based upper extremity robotic rehabilitation protocol
Koyaş, E., Saraç, M., Çetin, M., & Patoğlu, V. (2015) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2015.7281331
“Even though there are multiple ways to monitor the brain activity, non-invasive electroencephalogram (EEG) is the favored method for rehabilitation due to its portability and ease of use [4], [5].”
BackgroundSensing and Decoding Brain States for Predicting and Enhancing Human Behavior, Health, and Security
Bajwa, G. (2016) · University of North Texas Digital Library (University of North Texas) · doi:10.12794/metadc862723
Separable Spatio-spectral Patterns in EEG signals During Motor-imagery Tasks
Aghaei, A. S. (2014) · TSpace (University of Toronto)
Biopotential acquisition for brain–wheelchair interfaces
Guerrero, F. N., & Spinelli, E. M. (2008) · Elsevier eBooks · doi:10.1016/b978-0-12-812892-3.00004-2 · Cited by 1
Steer by ear: clinical and neurophysiological evaluation of a novel human-machine interface
Schmalfuß, L. (2018) · eDiss (Georg-August-Universität Göttingen) · doi:10.53846/goediss-6969
“…or spontaneous brain waves can be used to control word-processors (Birbaumer et al., 1999; Wolpaw, Birbaumer, McFarland, Pfurtscheller, & Vaughan, 2002), prostheses (Velliste et al., 2008) or even wheelchairs (Huang et al., 2012; J. D. R. Millán et al., 2009; Tanaka, Matsunaga, & Wang, 2005).”
Classification of unilateral motor tasks using spectral features of EEG
Robinson, N., Thomas, K. P., Vinod, A. P., & Sundaram, S. (2018) · IEEE Symposium Series on Computational Intelligence (SSCI) · doi:10.1109/ssci.2018.8628735
Hernandez-Ossa, K. A. (2018) · riUfes (Universidade Federal do Espírito Santo)
COMPARISON OF FEATURE EXTRACTION TECHNIQUES FOR EEG BASED RAIN-COMPUTER INTERFACE
Ghumman, M. K., & Singh, S. (2019) · INTERNATIONAL JOURNAL OF COMPUTER ENGINEERING & TECHNOLOGY · doi:10.34218/ijcet.10.2.2019.024
How to Use Brains and Computers to Enhance Brain Computer Interfacing
Stieger, J. (2020) · University of Minnesota Digital Conservancy (University of Minnesota)
Feature extraction from EEG signals and regularization for brain-computer interface
Mishuhina, V. (2019) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/141579 · Cited by 1
Performance Analysis and Comparison of Classification Algorithms for EEG-Based BCI System
Singh, N., Jindal, B., & Ghumman, M. K. (2021) · Lecture notes in networks and systems · doi:10.1007/978-981-16-1781-2_77
Harvesting Brain Signal Using Machine Learning Methods
Matsuno, K., & Nandikolla, V. K. (2021) · Journal of Engineering and Science in Medical Diagnostics and Therapy · doi:10.1115/1.4053064
Product Development Using Wearable Electronic Integrated Fabrics
(2015) · CRC Press eBooks · doi:10.1201/b19358-5
A deep learning model for classifying the thoughts of multiple individuals based on visual event
Luvsansambuu, U., Tengis, T., Bat-Erdene, M., & Amar, B. (2024) · International Conference on Electrical, Computer and Energy Technologies (ICECET) · doi:10.1109/icecet61485.2024.10698058 · Cited by 1
Spiking Neural Networks for Low-Power Medical Applications
Smith, L. C. I. (2024) · VTechWorks (Virginia Tech)
Brain–computer interface with non-invasive caps
Meng, W., Ma, L., Zuo, J., Liu, Q., & Xie, S. Q. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-40463-4.00009-0
Meng, W., Ma, L., Zuo, J., Liu, Q., & Xie, S. Q. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-40463-4.00001-6
Rewiring Brains: Pavlovian Conditioning-Based Small-Data Calibration for Enhancing BCI Performance
Tsunekawa, H., Martínez-Tejada, L. A., & Yoshimura, N. (2026) · CHI Conference Extended Abstracts on Human Factors in Computing Systems (CHI EA) · doi:10.1145/3772363.3798317
“Non-invasive MI-BCI, rooted in the 1970s and accelerated by the discovery of Event-Related Desynchronization (ERD) [26], has evolved from simple cursor control to complex applications like wheelchair navigation [17], prosthetic control [25], and VR/AR interaction [20].”
Nan, J., Jin, X., Lin, J., Conghui, L., Li, D., & Zheng, Q. (2026) · Information · doi:10.3390/info17060592
Transfer learning for target user in motor imagery EEG recognition
Cai, M., & Qu, Y. (2026) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2026.2705394
Dana, N. H., Ahsan, F., Bhuiyan, N. A., Zafir, E. I., Sarker, S. K., Yan, B., & Li, L. (2026) · Next research. · doi:10.1016/j.nexres.2026.102336
Metadata
- Authors
- Huang, D., Qian, K., Fei, D.-Y., Jia, W., Chen, X., & Bai, O.
- Affiliations
- Virginia Commonwealth University (US)
- State Key Laboratory of Digital Manufacturing Equipment and Technology (CN)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2012-05
- Volume
- 20
- Issue
- 3
- Pages
- 379-388
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2130286991
- Cited by
- 237
- References
- 45
- Citations by year
- 2026: 9 · 2025: 8 · 2024: 9 · 2023: 14 · 2022: 21 · 2021: 21 · 2020: 21 · 2019: 18 · 2018: 26 · 2017: 16 · 2016: 17 · 2015: 16 · 2014: 24 · 2013: 11 · 2012: 5
- FWCI
- 9.15
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- brain-computer interface, event-related desynchronization, event-related synchronization, motor imagery, motor execution, EEG-based control, assistive technology
- MeSH terms
- Adult, Algorithms, Brain, Cues, Electrodes, Electroencephalography, Evoked Potentials, Female, Hand, Humans, Functional Laterality, Male, Man-Machine Systems, Movement, Psychomotor Performance, User-Computer Interface, Wheelchairs, Video Games, Intention, Young Adult, Electroencephalography Phase Synchronization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.