Intuitive, Online, Simultaneous, and Proportional Myoelectric Control Over Two Degrees-of-Freedom in Upper Limb Amputees
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
We propose an approach for online simultaneous and proportional myoelectric control of two degrees-of-freedom (DoF) of the wrist, using surface electromyographic signals. The method is based on the nonnegative matrix factorization (NMF) of the wrist muscle activation to extract low-dimensional control signals translated by the user into kinematic variables. This procedure does not need a training set of signals for which the kinematics is known (labeled dataset) and is thus unsupervised (although it requires an initial calibration without labeled signals). The estimated control signals using NMF are used to directly control two DoFs of wrist. The method was tested on seven subjects with upper limb deficiency and on seven able-bodied subjects. The subjects performed online control of a virtual object with two DoFs to achieve goal-oriented tasks. The performance of the two subject groups, measured as the task completion rate, task completion time, and execution efficiency, was not statistically different. The approach was compared, and demonstrated to be superior to the online control by the industrial state-of-the-art approach. These results show that this new approach, which has several advantages over the previous myoelectric prosthetic control systems, has the potential of providing intuitive and dexterous control of artificial limbs for amputees.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In previous studies, investigators have provided prosthetic control signals by interfacing with intact muscles in the residual limb.”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [26]
In the citing paper
“This strategy has provided reasonable signal amplitude and some control of a prosthetic limb in patients undergoing transradial amputations (24–28).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [26]
In the citing paper
“Previous studies of simultaneous control of multiple DOFs have focused on controlling the wrist and hand open/closed (26, 28, 30).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [26]
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
Scheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Control of Fast-Reaching Movements by Muscle Synergy Combinations
d'Avella, A., Portone, A., Fernandez, L., & Lacquaniti, F. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.0830-06.2006 · Cited by 727
Computations Underlying the Execution of Movement: A Biological Perspective
Bizzi, E., Mussa-Ivaldi, F. A., & Giszter, S. (1991) · Science · doi:10.1126/science.1857964 · Cited by 677
Epidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508
Control of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495
Kuiken, T. A., Miller, L. A., Lipschutz, R. D., Lock, B. A., Stubblefield, K., Marasco, P. D., Zhou, P., & Dumanian, G. A. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60193-7 · Cited by 482
Jiang, N., Englehart, K. B., & Parker, P. A. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2007967 · Cited by 450
Self-citationMyoelectric Control of Artificial Limbs—Is There a Need to Change Focus? [In the Spotlight]
Jiang, N., Dosen, S., Muller, K.-R., & Farina, D. (2012) · IEEE Signal Processing Magazine · doi:10.1109/msp.2012.2203480 · Cited by 434
Self-citation
Research works printed but not linked: 1
- moore, 1920, On the reciprocal of the general algebraic matrix, Bull Am Math Soc, 26, 394
Cited by
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
“This approach has the interesting property of being unsupervised since any multichannel recording can be factorized, although in practice a short calibration is needed to solve the factorization indeterminacies [82], [84].”
BackgroundSelf-citationComparison of six electromyography acquisition setups on hand movement classification tasks
Pizzolato, S., Tagliapietra, L., Cognolato, M., Reggiani, M., Müller, H., & Atzori, M. (2017) · PLOS ONE · doi:10.1371/journal.pone.0186132 · Cited by 421
Al-Timemy, A. H., Khushaba, R. N., Bugmann, G., & Escudero, J. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2445634 · Cited by 336
“In addition, advanced control techniques such as pattern recognition (PR) based EMG control [13], [14] and regression techniques [14], [15] were also proposed and investigated.”
MethodParajuli, N., Sreenivasan, N., Bifulco, P., Cesarelli, M., Savino, S., Niola, V., Esposito, D., Hamilton, T. J., Naik, G. R., Gunawardana, U., et al. (2019) · Sensors · doi:10.3390/s19204596 · Cited by 332
“Some of the regression approach used for the control (movement) of prosthesis are linear and non-linear regression [16], ANN [58] and non-negative matrix factorization [40].”
BackgroundMethodCurrent state of digital signal processing in myoelectric interfaces and related applications
Hakonen, M., Piitulainen, H., & Visala, A. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.02.009 · Cited by 305
Vu, P. P., Vaskov, A. K., Irwin, Z. T., Henning, P. T., Lueders, D. R., Laidlaw, A. T., Davis, A. J., Nu, C. S., Gates, D. H., Gillespie, R. B., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aay2857 · Cited by 291
“Previous studies of simultaneous control of multiple DOFs have focused on controlling the wrist and hand open/closed (26, 28, 30).”
BackgroundToward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citationProsthetic Myoelectric Control Strategies: A Clinical Perspective
Roche, A. D., Rehbaum, H., Farina, D., & Aszmann, O. C. (2014) · Current Surgery Reports · doi:10.1007/s40137-013-0044-8 · Cited by 261
Self-citationJaramillo-Yánez, A., Benalcázar, M. E., & Mena-Maldonado, E. (2020) · Sensors · doi:10.3390/s20092467 · Cited by 259
“However, this evaluation fails to reflect the performance exhibited in online scenarios as it does not account for the adaptation of users to non-stationary signal features [43–47].”
BackgroundA survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252
Blind source identification from the multichannel surface electromyogram
Holobar, A., & Farina, D. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/7/r143 · Cited by 239
Self-citationIson, M., & Artemiadis, P. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/051001 · Cited by 225
“NMF DOF-wise calculations [44], mixing matrix [45],”
MethodIs Accurate Mapping of EMG Signals on Kinematics Needed for Precise Online Myoelectric Control?
Jiang, N., Vujaklija, I., Rehbaum, H., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2287383 · Cited by 218
“The efficacy of this scheme in realizing SPC has been now extensively demonstrated in able-bodied subjects [8], [10], as well as transradial amputees [9], [13], both in offline analysis [8]–[11], and in online validations [13].”
BackgroundMethodResultSelf-citationFleming, A., Stafford, N., Huang, S., Hu, X., Ferris, D. P., & Huang, H. (. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac1176 · Cited by 216
Li, W., Shi, P., & Yu, H. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.621885 · Cited by 211
Targeted Muscle Reinnervation and Advanced Prosthetic Arms
Cheesborough, J., Smith, L., Kuiken, T., & Dumanian, G. (2015) · Seminars in Plastic Surgery · doi:10.1055/s-0035-1544166 · Cited by 206
A motion-classification strategy based on sEMG-EEG signal combination for upper-limb amputees
Li, X., Samuel, O. W., Zhang, X., Wang, H., Fang, P., & Li, G. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0212-z · Cited by 199
“Both the sEMG and EEG acquisition systems used in the experiments have been integrated with a pre-filter by the producers [17, 18].”
Ngeo, J. G., Tamei, T., & Shibata, T. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-122 · Cited by 198
“using muscle synergy strategies extracted from a modified nonnegative matrix factorization algorithm to estimate the torque [8] and kinematics [9,10] of multiple DOFs produced at the wrists.”
MethodSamuel, O. W., Asogbon, M. G., Geng, Y., Al-Timemy, A. H., Pirbhulal, S., Ji, N., Chen, S., Fang, P., & Li, G. (2019) · IEEE Access · doi:10.1109/access.2019.2891350 · Cited by 185
New developments in prosthetic arm systems
Vujaklija, I., Farina, D., & Aszmann, O. (2016) · Orthopedic Research and Reviews · doi:10.2147/orr.s71468 · Cited by 185
“71,72 These systems may enable the users to intuitively control multiple DoFs in a simultaneous and proportional way.”
BackgroundSelf-citationAtzori, M., & Müller, H. (2015) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2015.00162 · Cited by 183
“Recently, semisupervised methods (NMF) and supervised methods (LR, ANN) were compared to evaluate the impact of precise kinematics estimation for accurately completing goal-directed tasks (Jiang et al., 2014b).”
BackgroundMethodInfluentialMuceli, S., Jiang, N., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2282898 · Cited by 172
“Sixteen channels were selected for comparison with our previous work [18].”
MethodResultInfluentialSelf-citationNon-invasive control interfaces for intention detection in active movement-assistive devices
Lobo-Prat, J., Kooren, P. N., Stienen, A. H. A., Herder, J. L., Koopman, H. F. J. M., & Veltink, P. H. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-168 · Cited by 173
“The importance and feasibility of simultaneous control has been investigated using several control modalities such as EEG- [190], EMG- [23,168] and head movement-based interfaces [172].”
BackgroundInfluentialSupport Vector Regression for Improved Real-Time, Simultaneous Myoelectric Control
Ameri, A., Kamavuako, E. N., Scheme, E. J., Englehart, K. B., & Parker, P. A. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2323576 · Cited by 171
Regression convolutional neural network for improved simultaneous EMG control
Ameri, A., Akhaee, M. A., Scheme, E., & Englehart, K. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab0e2e · Cited by 170
Is it Finger or Wrist Dexterity That is Missing in Current Hand Prostheses?
Montagnani, F., Controzzi, M., & Cipriani, C. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2398112 · Cited by 161
“, [22] demonstrated performant HMIs able to control in a simultaneous and proportional fashion the three DoFs of the wrist using surface myoelectric signals.”
Real-time simultaneous and proportional myoelectric control using intramuscular EMG
Smith, L. H., Kuiken, T. A., & Hargrove, L. J. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/6/066013 · Cited by 126
“These results are promising, and correspond with previous studies demonstrating the performance benefit of simultaneous myoelectric control in 2-DOF systems (Wurth and Hargrove 2013, Jiang et al 2013).”
ResultAdvances and Disturbances in sEMG-Based Intentions and Movements Recognition: A Review
Xu, H., & Xiong, A. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3068521 · Cited by 137
User adaptation in Myoelectric Man-Machine Interfaces
Hahne, J. M., Markovic, M., & Farina, D. (2017) · Scientific Reports · doi:10.1038/s41598-017-04255-x · Cited by 121
Self-citationIson, M. R., Vujaklija, I., Whitsell, B., Farina, D., & Artemiadis, P. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2417775 · Cited by 132
“for an intuitive motor learning-like 2-DoF control scheme [50].”
BackgroundSelf-citationControl of prosthetic hands via the peripheral nervous system
Ciancio, A. L., Cordella, F., Barone, R., Romeo, R. A., Bellingegni, A. D., Sacchetti, R., Davalli, A., Di Pino, G., Ranieri, F., Di Lazzaro, V., et al. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00116 · Cited by 131
“It requires only an initial calibration and has a success rate of around 95% (Jiang et al., 2014).”
BackgroundActive upper limb prostheses: a review on current state and upcoming breakthroughs
Marinelli, A., Boccardo, N., Tessari, F., Domenico, D. D., Caserta, G., Canepa, M., Gini, G. C., Barresi, G., Laffranchi, M., Michieli, L. D., et al. (2023) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/acac57 · Cited by 131
Effective force control by muscle synergies
Berger, D. J., & d’Avella, A. (2014) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2014.00046 · Cited by 125
“…by the CNS. Synergy-control could moreover be useful for achieving intuitive simultaneous and proportional control of myoelectric prostheses (Jiang et al., 2009, 2013), and robot arms (Artemiadis and Kyriakopoulos, 2010) and for the development of novel diagnostic tools and rehabilitation…”
BackgroundHahne, J. M., Dähne, S., Hwang, H., Müller, K., & Parra, L. C. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2401134 · Cited by 126
“Real-time myoelectric control based on regression techniques is demonstrated in [12]–[16].”
MethodEvaluation of Linear Regression Simultaneous Myoelectric Control Using Intramuscular EMG
Smith, L. H., Kuiken, T. A., & Hargrove, L. J. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2469741 · Cited by 112
“Many previous approaches for building linear models for simultaneous control, including NMF [21] and mixtures of linear experts [17], have trained the regression models using only EMG signals from corresponding contractions (e.g., the rotation models were trained using only data that included active supination or pron…”
MethodInfluentialHuman motor decoding from neural signals: a review
Tam, W.-K., Wu, T., Zhao, Q., Keefer, E. W., & Yang, Z. (2019) · BMC Biomedical Engineering · doi:10.1186/s42490-019-0022-z · Cited by 120
Shull, P. B., Jiang, S., Zhu, Y., & Zhu, X. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2905658 · Cited by 114
Jiang, N., Chen, C., He, J., Meng, J., Pan, L., Su, S., & Zhu, X. (2023) · National Science Review · doi:10.1093/nsr/nwad048 · Cited by 110
“further demonstrated the feasibility of the proposed NMF-based method for online SPC of two wrist joint DoFs on TR amputees [17].”
MethodSelf-citationWurth, S. M., & Hargrove, L. J. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-91 · Cited by 96
Vujaklija, I., Roche, A. D., Hasenoehrl, T., Sturma, A., Amsuess, S., Farina, D., & Aszmann, O. C. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00007 · Cited by 96
“, controlling a cursor to hit targets on a computer screen (Ameri et al., 2014; Jiang et al., 2014a).”
BackgroundMethodSelf-citationDhawan, A. S., Mukherjee, B., Patwardhan, S., Akhlaghi, N., Diao, G., Levay, G., Holley, R., Joiner, W. M., Harris-Love, M., & Sikdar, S. (2019) · Scientific Reports · doi:10.1038/s41598-019-45459-7 · Cited by 106
Ison, M. R., & Artemiadis, P. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2395731 · Cited by 100
Ma, C., Lin, C., Samuel, O. W., Xu, L., & Li, G. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102024 · Cited by 96
Real-time, simultaneous myoelectric control using a convolutional neural network
Ameri, A., Akhaee, M. A., Scheme, E., & Englehart, K. B. (2018) · PLoS ONE · doi:10.1371/journal.pone.0203835 · Cited by 94
Evaluation of matrix factorisation approaches for muscle synergy extraction
Ebied, A., Kinney‐Lang, E., Spyrou, L., & Escudero, J. (2018) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2018.04.003 · Cited by 91
Online mapping of EMG signals into kinematics by autoencoding
Vujaklija, I., Shalchyan, V., Kamavuako, E. N., Jiang, N., Marateb, H. R., & Farina, D. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0363-1 · Cited by 87
“The experimental protocol was similar to the one described in [23, 26].”
MethodResultSelf-citationLiu, J., Ren, Y., Xu, D., Kang, S. H., & Zhang, L. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2935182 · Cited by 84
“nition does not mimic natural human movements [9], [10], [33], [48], [50].”
BackgroundMuscle synergies for evaluating upper limb in clinical applications: A systematic review
Zhao, K., Zhang, Z., Wen, H., Liu, B., Li, J., d’Avella, A., & Scano, A. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e16202 · Cited by 80
Comparing EMG-Based Human-Machine Interfaces for Estimating Continuous, Coordinated Movements
Pan, L., Crouch, D. L., & Huang, H. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2937929 · Cited by 79
“real-time performance in estimating continuous movements from EMG: (1) nonnegative matrix factorization (NMF) for wrist movements [34], [37], (2) linear regression (LR) for wrist and hand movements [38]–[40], and (3) artificial neural”
MethodA Method for Locomotion Mode Identification Using Muscle Synergies
Afzal, T., Iqbal, K., White, G., & Wright, A. B. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2585962 · Cited by 78
“different subjects in upper limb task classification [28].”
Proportional estimation of finger movements from high-density surface electromyography
Celadon, N., Dosen, S. S., Jakob, I., Ariano, P., & Farina, D. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0172-3 · Cited by 76
“In addition, during online tests the subjects could use visual feedback to adapt the activations during the trial, as demonstrated in [40].”
BackgroundMethodSelf-citationIMU-Based Wrist Rotation Control of a Transradial Myoelectric Prosthesis
Bennett, D. A., & Goldfarb, M. T. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2682642 · Cited by 75
Liu, J., Kang, S. H., Xu, D., Ren, Y., Lee, S. J., & Zhang, L. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00480 · Cited by 77
“…have shown that artificial neural networks, being a widely used supervised non-linear approach, outperformed linear regression (a supervised linear approach) and non-negative matrix factorization (a linear unsupervised method) in the EMG decoding paradigm (Hahne et al., 2014; Jiang et al., 2014b).”
BackgroundMethodLin, C., Wang, B., Jiang, N., & Farina, D. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9666 · Cited by 75
“In myoeletric control, a movement of more than one DOF can be decomposed as the linear combination of basic DOFs, and the latent synergy basis and the control signal are nonnegative [29, 30].”
BackgroundMethodSelf-citationPan, L., Crouch, D. L., & Huang, H. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2838448 · Cited by 73
Counteracting Electrode Shifts in Upper-Limb Prosthesis Control via Transfer Learning
Prahm, C., Schulz, A., Paaben, B., Schoisswohl, J., Kaniušas, E., Dorffner, G., Hammer, B., & Aszmann, O. C. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2907200 · Cited by 72
Chen, C., Yu, Y., Sheng, X., Farina, D., & Zhu, X. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abf186 · Cited by 69
“The NMF-based control is described in details in [15, 16] and a brief explanation is provided here for clarity.”
InfluentialSelf-citationHwang, H.-J., Hahne, J. M., & Müller, K. (2017) · PLoS ONE · doi:10.1371/journal.pone.0186318 · Cited by 68
Brain–computer interfaces in the completely locked-in state and chronic stroke
Chaudhary, U., Birbaumer, N., & Ramos‐Murguialday, A. (2016) · Progress in brain research · doi:10.1016/bs.pbr.2016.04.019 · Cited by 67
A Review on Upper-Limb Myoelectric Prosthetic Control
Iqbal, N. V., Subramaniam, K., & Asmi, P. S. (2017) · IETE Journal of Research · doi:10.1080/03772063.2017.1381047 · Cited by 66
Fang, P., Ma, X., Li, X., Qiu, X., Gerhard, R., Zhang, X., & Li, G. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2766663 · Cited by 65
“The technique may yield rich information on muscle activities and motor commands and has the potential to detect even intricate body movements precisely [9], [10].”
BackgroundReal-Time Task Discrimination for Myoelectric Control Employing Task-Specific Muscle Synergies
Rasool, G., Iqbal, K., Bouaynaya, N. C., & White, G. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2410176 · Cited by 64
“, 6 single-DOF tasks and 12 two-DOF tasks (treating them as separate tasks, in contrast to the simultaneous approach as in [16]).”
BackgroundMethodInfluentialForce myography controlled multifunctional hand prosthesis for upper-limb amputees
Prakash, A., Sahi, A. K., Sharma, N., & Sharma, S. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102122 · Cited by 64
Vu, P. P., Irwin, Z. T., Bullard, A. J., Ambani, S. W., Sando, I. C., Urbanchek, M. G., Cederna, P. S., & Chestek, C. A. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2772961 · Cited by 61
“Previous continuous decoding studies have either used percutaneous fine-wire electrodes or surface electrodes to obtain EMG signals [13], [14], [35], [38] with few decoding isolated finger movements [16], [39].”
BackgroundThøgersen, M. B., Andoh, J., Milde, C., Graven‐Nielsen, T., Flor, H., & Petrini, L. (2020) · Journal of Pain · doi:10.1016/j.jpain.2020.06.002 · Cited by 60
A Myoelectric Control Interface for Upper-Limb Robotic Rehabilitation Following Spinal Cord Injury
McDonald, C. G., Sullivan, J. L., Dennis, T. A., & O’Malley, M. K. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2979743 · Cited by 57
“Techniques from control of prostheses and complex robotic systems [28]–[30] show promise for application to robotic rehabilitation.”
BackgroundSurface Electromyography Image-Driven Torque Estimation of Multi-DoF Wrist Movements
Yu, Y., Chen, C., Zhao, J., Sheng, X., & Zhu, X. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3050367 · Cited by 57
“Additionally, a DoF-wise nonnegative matrix factorization (NMF) approach has gained much attention due to its semi-supervision as well as comparable estimation performance with respect to supervised methods in real-time control [17].”
MethodBayesian Filtering of Surface EMG for Accurate Simultaneous and Proportional Prosthetic Control
Hofmann, D., Jiang, N., Vujaklija, I., & Farina, D. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2501979 · Cited by 54
“In conclusion, a method for sEMG amplitude estimation based on Bayesian filtering and its application to SPC for active prostheses has been proposed and validated.”
MethodResultSelf-citationMotor modules during adaptation to walking in a powered ankle exoskeleton
Jacobs, D. A., Koller, J. R., Steele, K. M., & Ferris, D. P. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0343-x · Cited by 54
“Prosthetic control of upper-limb devices have also used modules to generate more natural, intuitive control schemes [25].”
Online Finger Control Using High-Density EMG and Minimal Training Data for Robotic Applications
Barsotti, M., Dupan, S. S. G., Vujaklija, I., Dosen, S. S., Frisoli, A., & Farina, D. (2018) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2018.2885753 · Cited by 54
“Still, it has been previously shown that both regression [35] and classification [11] based myocontrol”
BackgroundSelf-citationShim, H.-M., & Lee, S. (2015) · Journal of Central South University · doi:10.1007/s11771-015-2698-0 · Cited by 52
Cascaded Adaptation Framework for Fast Calibration of Myoelectric Control
Zhu, X., Liu, J., Zhang, D., Sheng, X., & Jiang, N. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2562180 · Cited by 51
Self-citationClinical Perspectives in Upper Limb Prostheses: An Update
Roche, A. D., Lakey, B., Guerra, I. M., Vujaklija, I., Farina, D., & Aszmann, O. C. (2019) · Current Surgery Reports · doi:10.1007/s40137-019-0227-z · Cited by 52
“More recently, regression-based algorithms, such as Linear Regression (LR) [6] and Nonnegative Matrix Factorization (NMF) [7], proved to be a simple and promising approach to provide proportional and simultaneous control of multiple DOFs.”
MethodSelf-citationLobo-Prat, J., Kooren, P. N., Janssen, M., Keemink, A., Veltink, P., Stienen, A., & Koopman, B. (2016) · IEEE transactions on neural systems and rehabilitation engineering · doi:10.1109/tnsre.2016.2530762 · Cited by 50
“Common estimation methods include pattern-recognition-based algorithms [11] and regression-based algorithms [12]–[14].”
BackgroundMethodOnline Grasp Force Estimation From the Transient EMG
Martínez, I. J. R., Mannini, A., Clemente, F., & Cipriani, C. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3022587 · Cited by 48
“of freedom (DoF) [20], [21], or exhibiting adaptive behaviour [22], [23].”
BackgroundPiazza, C., Catalano, M. G., Godfrey, S. B., Rossi, M., Grioli, G., Bianchi, M., Zhao, K. D., & Bicchi, A. (2017) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2017.2751662 · Cited by 47
“, multisurface electromyography regression [2] and machinelearning techniques [3]) as well as surgical solutions (e.”
BackgroundCrouch, D. L., Pan, L., Filer, W. G., Stallrich, J. W., & Huang, H. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2859833 · Cited by 46
“This is not surprising, since previous studies investigating EMG decoding algorithms for wrist and hand movement similarly reported poorer performance for subjects with amputation than for able-bodied subjects [30], [31].”
MethodResultHu, R., Chen, X., Zhang, H., Zhang, X., & Chen, X. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3166764 · Cited by 45
Muscle-Synergy-Based Planning and Neural-Adaptive Control for a Prosthetic Arm
Li, G., Li, Z., Li, J., Liu, Y., & Qiao, H. (2021) · IEEE Transactions on Artificial Intelligence · doi:10.1109/tai.2021.3091038 · Cited by 44
Evaluation of Methods for the Extraction of Spatial Muscle Synergies
Zhao, K., Wen, H., Zhang, Z., Atzori, M., Müller, H., Xie, Z., & Scano, A. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.732156 · Cited by 43
“According to previous studies (Jiang et al., 2014; Vujaklija et al., 2018), thus, one synergy was extracted from each trial, while a total of two synergies were extracted for each degree of freedom, basically representing flexion and extension.”
MethodSurface EMG based handgrip force predictions using gene expression programming
Yang, Z., Chen, Y., Tang, Z., & Wang, J. (2016) · Neurocomputing · doi:10.1016/j.neucom.2016.05.038 · Cited by 43
Zhang, Q., Pi, T., Liu, R., & Xiong, C. (2020) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2020.2999532 · Cited by 42
“trol [12] [18] [24], [25].”
BackgroundNon-Invasive Analysis of Motor Unit Activation During Simultaneous and Continuous Wrist Movements
Chen, C., Yu, Y., Sheng, X., & Zhu, X. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3135575 · Cited by 42
Real-time, simultaneous myoelectric control using visual target-based training paradigm
Ameri, A., Kamavuako, E. N., Scheme, E., Englehart, K. B., & Parker, P. A. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2014.03.006 · Cited by 41
Montagnani, F., Controzzi, M., & Cipriani, C. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318892 · Cited by 40
A low-cost, wearable sEMG sensor for upper limb prosthetic application
Prakash, A., Kumari, B., & Sharma, S. (2019) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2019.1653391 · Cited by 40
Fu, Q., & Santello, M. (2018) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00071 · Cited by 40
“, 2013), intuitive control (Ajoudani et al., 2014; Jiang et al., 2014), and sensory feedback (Clemente et al.”
BackgroundEMG Signals based Human Action Recognition via Deep Belief Networks
Zhang, J., Ling, C., & Li, S. (2019) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2019.12.108 · Cited by 39
A Cable-Driven Upper Limb Rehabilitation Robot With Muscle-Synergy-Based Myoelectric Controller
Xie, C., Lyu, Y., Li, G., Tong, R. K., Xia, H., Song, R., & Li, Z. (2024) · IEEE Transactions on Robotics · doi:10.1109/tro.2024.3411849 · Cited by 40
Two degrees of freedom quasi-static EMG-force at the wrist using a minimum number of electrodes
Clancy, E. A., Martinez-Luna, C., Wartenberg, M., Dai, C., & Farrell, T. R. (2017) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2017.03.004 · Cited by 38
“…and studies used a wide selection of force or kinematic trajectories as the model output variable (Ameri et al. (Ameri, Scheme, 2014b) contrasted force vs. kinematic outputs; Jiang, Muceli and colleagues (Jiang et al., 2014; Muceli, Jiang, 2014) developed models requiring minimal supervision).”
BackgroundNoncontact Electromagnetic Wireless Recognition for Prosthesis Based on Intelligent Metasurface
Wang, H., Zhou, Y., Li, H., Liu, G., Yin, S. M., Li, P. J., Dong, S. Y., Gong, C. Y., Wang, S. Y., Li, Y. B., et al. (2022) · Advanced Science · doi:10.1002/advs.202105056 · Cited by 40
The future of upper extremity rehabilitation robotics: research and practice
Vu, P. P., Chestek, C. A., Nason, S. R., Kung, T. A., Kemp, S. W. P., & Cederna, P. S. (2020) · Muscle & Nerve · doi:10.1002/mus.26860 · Cited by 38
Multi-DoF continuous estimation for wrist torques using stacked autoencoder
Yu, Y., Chen, C., Sheng, X., & Zhu, X. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101733 · Cited by 35
A Classification Method for Myoelectric Control of Hand Prostheses Inspired by Muscle Coordination
Patel, G. K., Castellini, C., Hahne, J. M., Farina, D., & Dosen, S. S. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2861774 · Cited by 35
“a gripper with an active wrist), and has been used in some recent clinically relevant studies, investigating sequential [35], [36] and simultaneous [37], [38] myoelectric control.”
MethodSelf-citationAntuvan, C. W., & Masia, L. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2873839 · Cited by 33
“This metric is similar to the one used in [16], where instead they are calculated in terms of the optimal distance from the initial to the target.”
MethodCo-Adaptive Control of Bionic Limbs via Unsupervised Adaptation of Muscle Synergies
Yeung, D., Guerra, I. M., Barner-Rasmussen, I., Siponen, E., Farina, D., & Vujaklija, I. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2022.3150665 · Cited by 33
Self-citationMurciego, L. P., Henrich, M. C., Spaich, E. G., & Dosen, S. S. (2022) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-022-01056-w · Cited by 33
“The uniform placement provides an acceptable trade-off between ease of use (simple configuration) and performance [13, 15, 16].”
BackgroundJiang, N., Lorrain, T., & Farina, D. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-110 · Cited by 33
“The same algorithm was used in a recent online study [15].”
MethodSelf-citationExtraction of Nonlinear Synergies for Proportional and Simultaneous Estimation of Finger Kinematics
Dwivedi, S. K., Ngeo, J., & Shibata, T. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2967154 · Cited by 32
“strategies fall short in only being able to control a few number of DOFs [5], [6], among other existing limitations listed in [2].”
BackgroundMethodNovel postural control algorithm for control of multifunctional myoelectric prosthetic hands
Segil, J. L., & Weir (2015) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2014.05.0134 · Cited by 32
“, who compared a position and velocity control scheme with a nonnegative matrix factorization algorithm [34].”
Method
Metadata
- Authors
- Jiang, N., Rehbaum, H., Vujaklija, I., Graimann, B., & Farina, D.
- Affiliations
- Bernstein Center for Computational Neuroscience Göttingen (DE)
- Ottobock (Germany) (DE)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2014-05
- Volume
- 22
- Issue
- 3
- Pages
- 501-510
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2100338757
- Cited by
- 269
- References
- 22
- Citations by year
- 2026: 5 · 2025: 11 · 2024: 16 · 2023: 15 · 2022: 22 · 2021: 28 · 2020: 32 · 2019: 30 · 2018: 21 · 2017: 31 · 2016: 16 · 2015: 23 · 2014: 17
- FWCI
- 10.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- GRO (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- myoelectric control, upper limb amputees, two-degree-of-freedom control, surface electromyography, non-negative matrix factorization, proportional control, myoelectric prosthesis
- MeSH terms
- Adolescent, Adult, Aged, Algorithms, Amputation, Surgical, Amputees, Artificial Limbs, Biomechanical Phenomena, Calibration, Electromyography, Humans, Male, Middle Aged, Online Systems, Wrist, Upper Extremity, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.