Intuitive, Online, Simultaneous, and Proportional Myoelectric Control Over Two Degrees-of-Freedom in Upper Limb Amputees
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
We propose an approach for online simultaneous and proportional myoelectric control of two degrees-of-freedom (DoF) of the wrist, using surface electromyographic signals. The method is based on the nonnegative matrix factorization (NMF) of the wrist muscle activation to extract low-dimensional control signals translated by the user into kinematic variables. This procedure does not need a training set of signals for which the kinematics is known (labeled dataset) and is thus unsupervised (although it requires an initial calibration without labeled signals). The estimated control signals using NMF are used to directly control two DoFs of wrist. The method was tested on seven subjects with upper limb deficiency and on seven able-bodied subjects. The subjects performed online control of a virtual object with two DoFs to achieve goal-oriented tasks. The performance of the two subject groups, measured as the task completion rate, task completion time, and execution efficiency, was not statistically different. The approach was compared, and demonstrated to be superior to the online control by the industrial state-of-the-art approach. These results show that this new approach, which has several advantages over the previous myoelectric prosthetic control systems, has the potential of providing intuitive and dexterous control of artificial limbs for amputees.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In previous studies, investigators have provided prosthetic control signals by interfacing with intact muscles in the residual limb.”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [26]
In the citing paper
“This strategy has provided reasonable signal amplitude and some control of a prosthetic limb in patients undergoing transradial amputations (24–28).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [26]
In the citing paper
“Previous studies of simultaneous control of multiple DOFs have focused on controlling the wrist and hand open/closed (26, 28, 30).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [26]
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
Scheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Control of Fast-Reaching Movements by Muscle Synergy Combinations
d'Avella, A., Portone, A., Fernandez, L., & Lacquaniti, F. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.0830-06.2006 · Cited by 727
Computations Underlying the Execution of Movement: A Biological Perspective
Bizzi, E., Mussa-Ivaldi, F. A., & Giszter, S. (1991) · Science · doi:10.1126/science.1857964 · Cited by 677
Epidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508
Control of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495
Kuiken, T. A., Miller, L. A., Lipschutz, R. D., Lock, B. A., Stubblefield, K., Marasco, P. D., Zhou, P., & Dumanian, G. A. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60193-7 · Cited by 482
Jiang, N., Englehart, K. B., & Parker, P. A. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2007967 · Cited by 450
Self-citationMyoelectric Control of Artificial Limbs—Is There a Need to Change Focus? [In the Spotlight]
Jiang, N., Dosen, S., Muller, K.-R., & Farina, D. (2012) · IEEE Signal Processing Magazine · doi:10.1109/msp.2012.2203480 · Cited by 434
Self-citation
Research works printed but not linked: 1
- moore, 1920, On the reciprocal of the general algebraic matrix, Bull Am Math Soc, 26, 394
Cited by
Items 201–292 of 292
Electrotactile Feedback-Based Muscle Fatigue Alleviation for Hand Manipulation
Li, K., Zhou, Y., Zhou, D., Zeng, J., Fang, Y., Yang, J., & Liu, H. (2020) · International Journal of Humanoid Robotics · doi:10.1142/s0219843620500243 · Cited by 6
Control Strategies for Functional Upper Limb Prostheses
Hahne, J. M., Prahm, C., Vujaklija, I., & Farina, D. (2021) · Springer eBooks · doi:10.1007/978-3-030-60746-3_13 · Cited by 6
Self-citationConsistent control information driven musculoskeletal model for multiday myoelectric control
Zhao, J., Yu, Y., Sheng, X., & Zhu, X. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acef93 · Cited by 6
“Moreover, three metrics were calculated to evaluate the online performance, including completion time, path efficiency, and completion rate [42, 43].”
A Biologically-Inspired Robust Control System for Myoelectric Control
Muceli, S., Vujaklija, I., Jiang, N., Amsuess, S., Graimann, B., Aszmann, O. C., & Farina, D. (2016) · Biosystems & biorobotics · doi:10.1007/978-3-319-46669-9_158 · Cited by 6
Self-citationSmith, L. H., Kuiken, T., & Hargrove, L. J. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318562 · Cited by 6
Development of low-cost myoelectric prosthetic hand with force feedback
Sharma, N., Jadhav, A., Prakash, A., & Sharma, S. (2024) · International Conference on Integrated Circuits, Design, and Verification (ICDV) · doi:10.1109/icdv61346.2024.10616604 · Cited by 5
“The developed prosthetic hand using a loop proportional control scheme provides smooth operation and intuition-based control [15], [16].”
MethodData and Sensor Fusion Using FMG, sEMG and IMU Sensors for Upper Limb Prosthesis Control
Gharibo, J. S. (2021) · Scholarship@Western (Western University) · Cited by 5
Trace Finger Kinematics from Surface Electromyography by Using Kalman Decoding Method
Zhang, H., Zhou, X., Yang, Z., Tian, L., Zheng, Y., & Li, G. (2023) · IEEE International Conference on Cyborg and Bionic Systems (CBS) · doi:10.1109/cbs55922.2023.10115330 · Cited by 5
“The method based on nonnegative matrix factorization (NMF) [12] proposed by Jiang Ning et al. is another option, but is only used for wrist tracking in current researches.”
MethodRobust Control of Hand Prostheses from Surface EMG Signal for Transradial Amputees
Nastarin, A., Akter, A., & Awal, M. A. (2019) · International Conference on Advances in Electrical Engineering · doi:10.1109/icaee48663.2019.8975630 · Cited by 5
Fu, Q., & Santello, M. (2020) · Springer eBooks · doi:10.1007/978-3-030-38740-2_4 · Cited by 5
Basit, A., Nawaz, M., & Shafique, M. (2025) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn64981.2025.11228729 · Cited by 4
“…in EEG-Based Prosthetic Control : Non-invasive EEG signals suffer from low spatial resolution and susceptibility to contamination from non-neural sources, such as electromyographic (EMG) activity from facial and jaw muscles and electrooculographic (EOG) artifacts due to eye movements [8], [9].”
Improving Myoelectric Prosthetic Arm Proportional Control Under MUAP Envelope Colored Noise
Márquez-Figueroa, S., Shmaliy, Y. S., & Ibarra-Manzano, O. G. (2021) · IEEE Access · doi:10.1109/access.2021.3066279 · Cited by 4
“MatrixG can be determined using the techniques developed in [8], [34], [35] and is represented with the relevant matrix in (6).”
MethodStallrich, J. W., Islam, M. N., Staicu, A., Crouch, D. L., Pan, L., & Huang, H. (2020) · The Annals of Applied Statistics · doi:10.1214/20-aoas1324 · Cited by 4
“Jiang et al. (2009) and Jiang et al. (2014) proposed a generative model to incorporate underlying neurophysiological processes largely ignored by PR approaches.”
BackgroundWrist Torque Estimation by Combining Motor Unit Discharges With Musculoskeletal Model
Chen, C., Zhao, J., Yu, Y., Sheng, X., & Zhu, X. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3509859 · Cited by 4
Antuvan, C. W., Yen, S., & Masia, L. (2016) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2016.7523783 · Cited by 4
Age-Dependent Upper Limb Myoelectric Control Capability in Typically Developing Children
Gonzalez, M., Su, H., & Fu, Q. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3166800 · Cited by 4
“This is particularly useful to control many DoFs, such as in transhumeral amputees with targeted muscle reinnervation surgeries [29].”
BackgroundMethodInfluentialWang, R., Zhu, K., Zhang, Z., Li, J., & Pan, L. (2021) · International Conference on Mechatronics and Machine Vision in Practice (M2VIP) · doi:10.1109/m2vip49856.2021.9665114 · Cited by 4
Myoelectric control of artificial limb inspired by quantum information processing
Siomau, M., & Jiang, N. (2015) · Physica Scripta · doi:10.1088/0031-8949/90/3/035001 · Cited by 4
Self-citationTowards Natural Control of Artificial Limbs
Ortiz-Catalan, M. (2014) · Chalmers Publication Library (Chalmers University of Technology) · Cited by 4
Decoding human motion intention using myoelectric signals for assistive technologies
Antuvan, C. W. (2019) · doi:10.32657/10220/48046 · Cited by 4
Hierarchical Graphical Models for Context-Aware Hybrid Brain-Machine InterfacesPreprint
Özdenizci, O., Günay, S. Y., Quivira, F., & Erdogmus, D. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1809.05635 · Cited by 4
“Primarily based on the notion of a lower-dimensional muscle synergy framework controlling a wider range of hand movements [17], low-rank representation of multichannel EMG activity through non-negative matrix factorization (NMF) provides significant insights [9–11].”
BackgroundResultSimultaneous and Proportional Control Based on an Enhanced Musculoskeletal Model
Pan, L., Liu, D., Wang, R., & Li, J. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3543912 · Cited by 3
“The advanced algorithms include linear regression [12], [13], support vector machine [14], artificial neural network [10], non-negative matrix factorization (NMF) [15], [16], and deep learning [17], [18].”
High-fidelity interfacing for bionic rehabilitation
Vujaklija, I. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-23987-8.00003-1 · Cited by 3
Self-citationGuo, R., Chen, C., & Zhu, X. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3504577 · Cited by 3
Deng, H., Wei, Z., Hu, X., Zeng, H., Song, A., Zhang, D., & Farina, D. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3545818 · Cited by 3
“The chosen task parameters followed previous studies [20], [42], allowing to distinguish between accurately directed movements and those merely brushing the target.”
Self-citationRobustness of Muscle Synergies under Variant Muscle Contraction Force during Forearm Movements
Deng, H., Cheung, V. C. K., Geng, Y., Samuel, M. G. A., Samuel, O. W., & Li, G. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175912 · Cited by 3
“For this reason, the muscle synergy has been recently applied for the intuitive, simultaneous and proportional myoelectric control of multiple degrees of freedom (DOFs) upper limb prosthesis [16-18].”
MethodA Neural-Driven Musculoskeletal Model for Continuous Estimation of Hand and Wrist Movements
Yue, S., Li, J., & Pan, L. (2022) · IEEE International Conference on Cyber Technology in Automation, Control, and Intelligent Systems · doi:10.1109/cyber55403.2022.9907258 · Cited by 3
EMG-Controlled Human-Robot Interfaces
Bu, N., Tsuji, T., & Fukuda, O. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-803137-7.00004-5 · Cited by 3
Pan, L., Zhang, D., Jiang, N., Sheng, X., & Zhu, X. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa758e · Cited by 3
“The online SPC approach applied in the current study, proposed by Jiang et al [15], does not require kinetic or kinematic information in the training set as labeling information.”
MethodSelf-citationTeh, Y., Woodward, R. B., & Hargrove, L. J. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512693 · Cited by 3
“Several studies have modified conventional discrete controllers such as linear discriminant analysis (LDA) classifiers [5], [6], while others have shifted focus to continuous controllers such as linear and nonlinear regression [7], [8], nonnegative matrix factorization [9], and parallel dual-site controllers [10].”
BackgroundMethodKUKA Real-Time Control through Angle Estimation of Wrist from sEMG with Support Vector Regression
Feng, X., Ai, Q., & Meng, W. (2018) · doi:10.1145/3297156.3297240 · Cited by 3
“Table I gives the RMSEs between the true joint angles and the estimated ones under various types of estimation model.”
MethodInfluentialSynergy Estimation for Myoelectric Control Using Regularized NMF
Bahadur, R., Rehman, S. U., & Khattak, S. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857578 · Cited by 3
Wang, K.-J., & Mao, Z. (2021) · IEEE International Conference on Consumer Electronics-Asia (ICCE-Asia) · doi:10.1109/icce-asia53811.2021.9641874 · Cited by 3
Machine learning based myoelectric control
Hahne, J. M. (2016) · DepositOnce · doi:10.14279/depositonce-5054 · Cited by 3
Hand neuro-motor characterization and motor intention decoding in Duchenne muscular dystrophy
Nizamis, K. (2019) · doi:10.3990/1.9789036547833 · Cited by 3
Dimensionality of forearm muscle activation in transradial amputeesPreprint
McClanahan, A. J., Moench, M., & Fu, Q. (2020) · doi:10.21203/rs.3.rs-27070/v1 · Cited by 3
“Considering the drawbacks of pattern recognition approaches, an alternative has been proposed to extract proportional control signals with multiple degrees of freedom (DoFs) simultaneously via linear [16]–[19] or nonlinear [20]–[22] regression algorithms.”
MethodMetric Learning for Structured Data
Paaßen, B. (2019) · PUB – Publications at Bielefeld University (Bielefeld University) · doi:10.4119/unibi/2935545 · Cited by 3
Co-Adaptive Velocity and Position Control of 3-DoFs Prosthesis via Incremental Learning
Domenico, D. D., Egle, F., Marinelli, A., Canepa, M., Gruppioni, E., Boccardo, N., Laffranchi, M., & Castellini, C. (2026) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2026.3657400 · Cited by 2
“Comparisons using cursor-control tasks show improved performance with velocity-based control [51], where users adopted a pulsing strategy [51], performing small muscle contractions to move the cursor incrementally, followed by pauses for precise task completion [52].”
Bakshi, K., Biswas, S., Manjunatha, M., & Kumar, C. S. (2017) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2017.8008309 · Cited by 2
“As already identified, the drawback of classification of single DoF or multiple DoFs based approach, as implemented in the state of the art prosthesis, is still far from the intuitive manner a user would prefer to control his limb or prosthesis as its replacement[4], [5].”
BackgroundCan Multi-DoF Training Improve Robustness of Muscle Synergy Inspired Myocontrollers?
Yeung, D., Farina, D., & Vujaklija, I. (2019) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2019.8779520 · Cited by 2
Self-citationPradhan, A., Kuruganti, U., Hill, W., Jiang, N., & Chester, V. L. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176603 · Cited by 2
“The performance of a virtual prosthesis task was assessed using the completion rate (CR) similar to other studies [5, 10, 11, 15, 20, 21].”
BackgroundMethodSelf-citationComparison of SEMG-Based Hand Gesture Classifiers
Lello, G. C. D., Chaves, G. S., Caldeira, J. F., & Lima, M. V. S. (2024) · Learning and Nonlinear Models · doi:10.21528/lnlm-vol22-no2-art4 · Cited by 2
Jaquier, N., Castellini, C., & Calinon, S. (2017) · elib (German Aerospace Center) · doi:10.13140/rg.2.2.18780.28804 · Cited by 2
“, [2, 3, 4], a full, clinically accepted application still has to appear.”
BackgroundImproving the myoelectric motion classification performance by feature filtering strategy
Li, X., Zheng, Y., Xia, Z., Li, G., & Fang, P. (2017) · IEEE International Conference on Real-time Computing and Robotics (RCAR) · doi:10.1109/rcar.2017.8311894 · Cited by 2
“Electromyography Pattern Recognition (EMG-PR) control method is an advanced and intelligent technique and have been investigated in many laboratories worldwide [1-4].”
MethodA Motor Unit-specific Images Based Scheme for Continuous Estimation of Wrist Torques - A Pilot Study
Yu, Y., Chen, C., Sheng, X., & Zhu, X. (2020) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc42975.2020.9283000 · Cited by 2
“, root mean square [8], [9] and mean absolute value [10].”
BackgroundEMG-based Gesture Recognition using Extreme Learning Machine
Tyagi, T., Pandey, A., & Singh, K. R. (2023) · International Conference on Artificial Intelligence and Signal Processing (AISP) · doi:10.1109/aisp57993.2023.10134797 · Cited by 2
“To overcome this challenge surgical procedures like targeted muscle reinnervation are used to identify optimal points for recording the myoelectric signals for prosthesis control [10].”
MethodHand Gesture Classification using sEMG Data:Combining Gesture Detection and Cross-Validation
Chaves, G. S., Vieira, A., & Lima, M. V. S. (2024) · Congresso Brasileiro de Inteligência Computacional (CBIC) · doi:10.21528/cbic2023-029 · Cited by 2
Development and Validation of a Postural Controller for Advanced Myoelectric Prosthetic Hands
Segil, J. L. (2014) · CU Scholar (University of Colorado Boulder) · Cited by 2
EMG-Controlled Hand Teleoperation Using a Continuous Teleoperation Subspace.Preprint
Meeker, C., & Ciocarlie, M. (2018) · arXiv (Cornell University) · Cited by 2
Investigations on upper limb prosthesis control with an active elbow
Mérad, M. (2017) · theses.fr (ABES) · doi:10.70675/49868946zf54fz40ccza88bzda97441889ed · Cited by 2
“Research groups are thus now focusing on simultaneous proportional prosthetic control (Amsuess et al., 2015, 2016; Ison et al., 2016; Jiang et al., 2009, 2014; Muceli and Farina, 2012; Nielsen et al., 2011; Park et al., 2016), as illustrated in Fig.”
BackgroundRobust Electromyography Based Control of Multifunctional Prostheses of The Upper Extremity
Amsuess, S. (2015) · eDiss (Georg-August-Universität Göttingen) · doi:10.53846/goediss-4989 · Cited by 2
Multi-DoF Continuous Estimation for Wrist Torques Using Convolutional Neural Network
Fang, Y., Yu, Y., Guo, W., & Sheng, X. (2024) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio64047.2024.10907617 · Cited by 1
“Compared with discrete gesture decoding using pattern recognition, regression-based strategies have been proposed to decode multi-DoF motion information for simultaneous and proportional control (SPC) [6], [7].”
Gesture Prediction Using Surface-EMG Signals
Panigrahi, S., Seal, S., Lal, S., & Naik, G. R. (2025) · Communications in computer and information science · doi:10.1007/978-3-031-90577-3_37 · Cited by 1
Cady, S. R., Lambrecht, J. M., & Tyler, D. J. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae24ae · Cited by 1
“Simultaneous, independent, and proportional prosthetic control has been demonstrated in 2 DOFs [68– 70], 3 DOFs [16, 19, 69, 71], and 4 DOFs [17, 35] using implanted or surface EMG inputs.”
Bernardini, A., Meattini, R., Pasquali, A., Laudante, G., Gentile, C., Gruppioni, E., Palli, G., & Melchiorri, C. (2026) · IEEE Transactions on Robotics · doi:10.1109/tro.2026.3696049 · Cited by 1
Chen, C., Guo, R., Li, D., Shi, S., Guo, W., Meng, J., Gu, G., & Zhu, X. (2026) · Science Advances · doi:10.1126/sciadv.aej0245 · Cited by 1
“The NMF-based control strategy models the root mean square (RMS) features of sEMG signals as a linear combination of basic components, as described in detail in ( 42 ).”
López, J. M., Martí, G., Méndez, S. T. P., Candelas-Herías, F. A., Úbeda, A., & Torres, F. M. (2020) · Jornadas de Automática · doi:10.17979/spudc.9788497497565.0094 · Cited by 1
Gait Motor Function Evaluation Based on Muscle Synergy Method
Deng, Y., Gao, F., Chen, C., & Cao, Y. (2019) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio49542.2019.8961633 · Cited by 1
“In the extraction phase, it is necessary to use the synergistic element matrix W, as calculated by the training phase, while the characteristic signal ( )test M E is to be analysed, in turn, to find the activation coefficient matrix H with the generalized inverse, which is easy to cause the negative value [11].”
MethodCharacterizing the Effect of Motion Class Taxonomy on the Performance of Hand Motion Classifiers
Shahzad, W., Ayaz, Y., Khan, M. J., Naseer, N., & Zafar, A. (2020) · International Conference on Mechanical, Electronics, Computer, and Industrial Technology (MECnIT) · doi:10.1109/mecnit48290.2020.9166608 · Cited by 1
“This has resulted in a stark performance difference between the academic results and the actual clinical performance [11].”
ResultAi, Q., Liu, Q., Meng, W., & Xie, S. Q. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-814597-5.00001-1 · Cited by 2
Translating Advanced Myocontrol for Upper Limb Prostheses from the Laboratory to Clinics
Vujaklija, I. (2017) · eDiss (Georg-August-Universität Göttingen) · doi:10.53846/goediss-6009 · Cited by 1
Self-citationHigher-order tensor decompositions for muscle synergy analysis
Ebied, A. (2019) · ERA · Cited by 1
Restoring Fine Motor Prosthetic Hand Control via Peripheral Neural Technology
Vu, P. P. (2019) · Deep Blue (University of Michigan) · Cited by 1
Intuitive Myoelectric Control of Upper Limb Prostheses
Rehbaum, H. (2014) · eDiss (Georg-August-Universität Göttingen) · doi:10.53846/goediss-4483 · Cited by 1
Self-citationA Continuous sEMG-Based Prosthetic Hand Control System Without Motion or Force SensorsPreprint
Liu, G., Sun, Y., Wang, Z., Xi, C., He, Z., Guo, S., Zhang, R., & Yao, D. (2024) · arXiv (Cornell University) · doi:10.48550/arxiv.2407.00014 · Cited by 1
“Although previous studies indicate some similarity in muscle activation patterns between amputees and non-disabled individuals [41], further verification with amputee participants is necessary.”
Interaction-Driven Approaches for Efficient and Autonomous Calibration of Myoelectric Controllers
Gigli, A. (2024) · elib (German Aerospace Center) · doi:10.25593/open-fau-889 · Cited by 1
Identification of isotonic forearm motions using muscle synergies for brain injured patients
Geng, Y., Ouyang, Y., Samuel, O. W., Yu, W., Wei, Y., Bi, S., Lu, X., & Li, G. (2017) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2017.8008431
“Furthermore, muscle synergies extracted by non-negative factorization (NMF) were used for 2-DOF and 3-DOF simultaneous and proportional control of myoelectric prosthesis [14, 15].”
MethodContext- and Physiology-aware Machine Learning for Upper-Limb Myocontrol
Patel, G. K. (2018) · eDiss (Georg-August-Universität Göttingen) · doi:10.53846/goediss-6872
Studies of the relationship between the surface electromyogram, joint torque and impedance
Dai, C. (2016) · Digital WPI
A muscle synergies-based movements detection approach for recognition of the wrist movements
Masoumdoost, A., Saadatyar, R., & Kobravi, H. R. (2020) · EURASIP Journal on Advances in Signal Processing · doi:10.1186/s13634-020-00699-y
“The other challenge is detecting the movements with multi DoF [17, 18], and some research works were focused on detecting the movement with only one DoF [3, 6, 8].”
BackgroundMethodInfluentialOnline Personalisation of Human-Prosthetic Interfaces
Garcia-Rosas, R. (2020) · Minerva Access (University of Melbourne)
Proportional Myoelectric Control of High-DOF Finger Kinematics Using Synergistic Models
Ngeo, J. (2016) · Institutional Repositories DataBase (IRDB) · doi:10.34413/dr.01329
Statistical learning and inference in neural signal processing: applications to brain interfaces
Özdenizci, O. (2020) · Digital Repository Service (Northeastern University) · doi:10.17760/d20382835
Li, Z., Li, J., & Pan, L. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-13835-5_39
Triggering a change: switching behaviour in multi-articulating hand prostheses
Heerschop, A. (2023) · University of Groningen research database (University of Groningen / Centre for Information Technology) · doi:10.33612/diss.623543663
Biyouki, F., Pooyan, M., & Kobravi, H.-R. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.105256
A testosterone pattern-based sEMG signal classification method using Singular Spectrum Analysis
Tyagi, T., Pandey, A., & Singh, K. R. (2023) · International Conference on Computational Intelligence and Sustainable Engineering Solutions (CISES) · doi:10.1109/cises58720.2023.10183549
“Usually, the number of available channels is constrained due to the need to embed electrodes within the prosthetic limb and in order to find the optimal position for these limited electrodes for recording EMG signal, TMR (Targeted Muscle Reinnervation) surgery is done [10].”
BackgroundPeng, C., Yang, D., Cheng, M., Dai, J., Zhao, D., & Jiang, L. (2023) · arXiv (Cornell University) · doi:10.48550/arxiv.2308.06891
Garenfeld, M. A. (2023) · VBN Forskningsportal (Aalborg Universitet) · doi:10.54337/aau561809161
Between Stimulation and Biologics
Miranda, S. P., Xu, E., Alexis, M., & Ali, Z. S. (2025) · Springer eBooks · doi:10.1007/978-3-031-73931-6_70
Deng, H., Zeng, H., Xu, X., Ping, J., & Song, A. (2025) · International Conference on Robotics and Control Engineering (RobCE) · doi:10.1145/3733774.3735334
“…low-dimensional representations of muscle activity, various studies have applied linear dimensionality reduction (DR) techniques—such as Principal Component Analysis (PCA), Non-negative Matrix Factorization (NMF), and Kalman Filtering—to extract underlying control-relevant manifolds[11][12].”
Pan, L., Yan, X., Li, J., Li, J., & Wang, S. (2025) · Science China Technological Sciences · doi:10.1007/s11431-025-3026-1
“This approach adopts a regression algorithm to continuously map the characteristics of sEMG signals to joint angles or velocities, enabling smooth and precise movement control [7–9].”
Lukyanenko, P., Dewald, H. A., Lambrecht, J. M., Kirsch, R. F., Tyler, D. J., & Williams, M. R. (2021) · Figshare · doi:10.6084/m9.figshare.14247683
Murciego, L. P. (2017) · Electronic Theses and Dissertations Repository (University of Pisa)
Cole, N. M. (2020) · OhioLink ETD Center (Ohio Library and Information Network)
Chan, Y. L., Tew, Y., Goh, C. P., & Chan, C. K. (2026) · IEEE International Conference on Computation, Big-Data and Engineering (ICCBE) · doi:10.3390/engproc2026128020
Zhang, Y., Yang, Y., Wang, C., Li, Q., Li, J., Li, J., & Pan, L. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.110128
Canepa, M. (2026) · Open Research Online (The Open University) · doi:10.21954/ou.ro.00109751
Simulation-Driven Imitation Learning for Biosignals-Free Shared-Autonomy Prosthetic GraspingPreprint
Shi, K., Lu, W., Chen, H., da Fonseca, V. P., Zou, T., Zhao, H., & Jiang, X. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2606.07389
A novel SE-ResNet architecture for continuous estimation of wrist and hand movements from HD-sEMG
Pan, L., Chen, Z., & Li, J. (2026) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-026-03595-z
“Nonetheless, machine learning meth-ods entail the search for an optimal feature set, which can be a time-consuming endeavor [ 14 , 15].”
Hariri, A. R., Englehart, K. B., & Scheme, E. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2610.24802
Metadata
- Authors
- Jiang, N., Rehbaum, H., Vujaklija, I., Graimann, B., & Farina, D.
- Affiliations
- Bernstein Center for Computational Neuroscience Göttingen (DE)
- Ottobock (Germany) (DE)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2014-05
- Volume
- 22
- Issue
- 3
- Pages
- 501-510
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2100338757
- Cited by
- 269
- References
- 22
- Citations by year
- 2026: 5 · 2025: 11 · 2024: 16 · 2023: 15 · 2022: 22 · 2021: 28 · 2020: 32 · 2019: 30 · 2018: 21 · 2017: 31 · 2016: 16 · 2015: 23 · 2014: 17
- FWCI
- 10.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- GRO (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- myoelectric control, upper limb amputees, two-degree-of-freedom control, surface electromyography, non-negative matrix factorization, proportional control, myoelectric prosthesis
- MeSH terms
- Adolescent, Adult, Aged, Algorithms, Amputation, Surgical, Amputees, Artificial Limbs, Biomechanical Phenomena, Calibration, Electromyography, Humans, Male, Middle Aged, Online Systems, Wrist, Upper Extremity, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.