Abstract
We propose an approach for online simultaneous and proportional myoelectric control of two degrees-of-freedom (DoF) of the wrist, using surface electromyographic signals. The method is based on the nonnegative matrix factorization (NMF) of the wrist muscle activation to extract low-dimensional control signals translated by the user into kinematic variables. This procedure does not need a training set of signals for which the kinematics is known (labeled dataset) and is thus unsupervised (although it requires an initial calibration without labeled signals). The estimated control signals using NMF are used to directly control two DoFs of wrist. The method was tested on seven subjects with upper limb deficiency and on seven able-bodied subjects. The subjects performed online control of a virtual object with two DoFs to achieve goal-oriented tasks. The performance of the two subject groups, measured as the task completion rate, task completion time, and execution efficiency, was not statistically different. The approach was compared, and demonstrated to be superior to the online control by the industrial state-of-the-art approach. These results show that this new approach, which has several advantages over the previous myoelectric prosthetic control systems, has the potential of providing intuitive and dexterous control of artificial limbs for amputees.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In previous studies, investigators have provided prosthetic control signals by interfacing with intact muscles in the residual limb.”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [26]
In the citing paper
“This strategy has provided reasonable signal amplitude and some control of a prosthetic limb in patients undergoing transradial amputations (24–28).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [26]
In the citing paper
“Previous studies of simultaneous control of multiple DOFs have focused on controlling the wrist and hand open/closed (26, 28, 30).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [26]
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
Scheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Control of Fast-Reaching Movements by Muscle Synergy Combinations
d'Avella, A., Portone, A., Fernandez, L., & Lacquaniti, F. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.0830-06.2006 · Cited by 727
Computations Underlying the Execution of Movement: A Biological Perspective
Bizzi, E., Mussa-Ivaldi, F. A., & Giszter, S. (1991) · Science · doi:10.1126/science.1857964 · Cited by 677
Epidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508
Control of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495
Kuiken, T. A., Miller, L. A., Lipschutz, R. D., Lock, B. A., Stubblefield, K., Marasco, P. D., Zhou, P., & Dumanian, G. A. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60193-7 · Cited by 482
Jiang, N., Englehart, K. B., & Parker, P. A. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2007967 · Cited by 450
Self-citationMyoelectric Control of Artificial Limbs—Is There a Need to Change Focus? [In the Spotlight]
Jiang, N., Dosen, S., Muller, K.-R., & Farina, D. (2012) · IEEE Signal Processing Magazine · doi:10.1109/msp.2012.2203480 · Cited by 434
Self-citation
Research works printed but not linked: 1
- moore, 1920, On the reciprocal of the general algebraic matrix, Bull Am Math Soc, 26, 394
Cited by
Items 101–200 of 292
Li, D., Kang, P., Yu, Y., & Shull, P. B. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3373432 · Cited by 31
Design and testing of an under-actuated surface EMG-driven hand exoskeleton
Lince, A., Celadon, N., Battezzato, A., Favetto, A., Appendino, S., Ariano, P., & Paleari, M. (2017) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2017.8009325 · Cited by 31
Luo, X., Wu, X., Chen, L., Yun, Z., Zhang, L., Li, G., & Hou, W. (2019) · Sensors · doi:10.3390/s19030610 · Cited by 31
“[26] proposed an algorithm extracting neural control information from sEMG based on the synergy theorem, to drive myoelectric prostheses performing upper limb movements in multiple degrees of freedom [27].”
MethodData Management for Transfer Learning Approaches to Elbow EMG-Torque Modeling
Jiang, X., Bardizbanian, B., Dai, C., Chen, W., & Clancy, E. A. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3069961 · Cited by 33
A low-cost transradial prosthesis controlled by the intention of muscular contraction
Prakash, A., & Sharma, S. (2021) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-021-00972-w · Cited by 30
Wrist Torque Estimation via Electromyographic Motor Unit Decomposition and Image Reconstruction
Yu, Y., Chen, C., Sheng, X., & Zhu, X. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3041861 · Cited by 29
Evaluation of a Simultaneous Myoelectric Control Strategy for a Multi-DoF Transradial Prosthesis
Piazza, C., Rossi, M., Catalano, M. G., Bicchi, A., & Hargrove, L. J. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3016909 · Cited by 29
“matrix factorization [19], [20], [21], have been proposed and have recently gained popularity.”
BackgroundLukyanenko, P., Dewald, H. A., Lambrecht, J., Kirsch, R. F., Tyler, D. J., & Williams, M. R. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00833-3 · Cited by 27
Gurgone, S., Borzelli, D., Pasquale, P. D., Berger, D. J., Baldi, T. L., D’Aurizio, N., Prattichizzo, D., & d’Avella, A. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac47db · Cited by 27
“…a prosthetic limb by an amputee, as a replacement of the missing limb, can rely either on the detection of movement intention by EMG pattern recognition [16, 17] or on the direct control of one or multiple degrees of freedom (DoFs) using EMG signals recorded from many different muscles [4, 18, 19].”
Ebied, A., Kinney‐Lang, E., Spyrou, L., & Escudero, J. (2019) · IEEE Access · doi:10.1109/access.2019.2902122 · Cited by 27
“This application of muscle synergy has received substantial attention recently [29], [38]–[40] and we expect that its selection to illustrate our study will promote uptake of the methods.”
MethodFranzke, A. W., Kristoffersen, M., Jayaram, V., van der Sluis, C. K., Murgia, A., & Bongers, R. M. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3029873 · Cited by 27
Development of a control system for artificially rehabilitated limbs: a review
Bhuiyan, M. S. H., Choudhury, I. A., & Dahari, M. (2014) · Biological Cybernetics · doi:10.1007/s00422-014-0635-1 · Cited by 25
“10 A myoelectric control system based on pattern recognition (Asghari Oskoei and Hu 2007) Jiang et al. 2013, 2014).”
MethodThe MSC Prosthetic Hand: Rapid, Powerful, and Intuitive
Cho, Y., Lee, Y., Kim, P., Jeong, S., & Kim, K.-S. (2022) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2022.3140444 · Cited by 25
“finger movement or force in various ways, such as the linear matrix decomposition method [9], [10], the supervised learning method based on machine learning technology [11], and the”
MethodTask-Oriented Muscle Synergy Extraction Using An Autoencoder-Based Neural Model
Buongiorno, D., Cascarano, G. D., Camardella, C., Feudis, I. D., Frisoli, A., & Bevilacqua, V. (2020) · Information · doi:10.3390/info11040219 · Cited by 25
“Previous studies showed how synergistic models are useful for achieving either multi-DoF planar movements with the upper-limb [28] and wrist [29] or upper-limb force prediction during isometric contractions [14].”
BackgroundHe, Z., Qin, Z., & Koike, Y. (2022) · Applied Sciences · doi:10.3390/app12083772 · Cited by 25
“Several recent studies have used muscle synergy information for predictive analyses [27,28].”
BackgroundAn enhanced EMG-driven Musculoskeletal model based on non-negative matrix factorization
Li, J., Wang, R., & Pan, L. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.104178 · Cited by 24
Smith, L. H., Kuiken, T., & Hargrove, L. J. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2410755 · Cited by 24
“A few studies have recently demonstrated the potential benefit of providing simultaneous control compared to sequential control, allowing for faster completion times and greater efficiencies in tasks requiring use of more than one DOF [10], [16].”
Li, X., Fang, P., Tian, L., & Li, G. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8036848 · Cited by 24
Nizamis, K., Stienen, A. H. A., Kamper, D. G., Keller, T., Plettenburg, D. H., Rouse, E. J., Farina, D., Koopman, H. F. J. M., & Sartori, M. (2019) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2019.2912453 · Cited by 24
“The user intent is estimated by means of sEMG from the affected limb [32], [33].”
BackgroundMethodSelf-citationOlsson, A. E., Malešević, N., Björkman, A., & Antfolk, C. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00832-4 · Cited by 24
“As in previous studies [38, 44], a high value of R(2) was seen as indicative of the validity of the Fitts’s law test.”
ResultDirectional Forgetting for Stable Co-Adaptation in Myoelectric Control
Yeung, D., Farina, D., & Vujaklija, I. (2019) · Sensors · doi:10.3390/s19092203 · Cited by 24
“Four metrics were implemented to quantify each subject’s performance across the runs and such metrics have been used in past studies on myoelectric control [15,16,34].”
BackgroundMethodSelf-citationEffects of muscle fatigue on the usability of a myoelectric human-computer interface
Barszap, A. G., Skavhaug, I.-M., & Joshi, S. S. (2016) · Human Movement Science · doi:10.1016/j.humov.2016.06.009 · Cited by 23
Bakshi, K., Manjunatha, M., & Kumar, C. S. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.06.012 · Cited by 22
Yang, X., Yan, J., Yin, Z., & Liu, H. (2022) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2022.3207359 · Cited by 22
“[42] achieved simultaneous and proportional control of wrist flexion/extension and wrist pronation/supination using sEMG and nonnegative matrix factorization, with a CR of 95.”
MethodKim, P., Kim, K.-S., & Kim, S. (2017) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2017.2751549 · Cited by 22
“, that amputees and the able bodied have similar real-time performances [25], [35].”
BackgroundResultChen, C., Yu, Y., Sheng, X., Meng, J., & Zhu, X. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2023.3260209 · Cited by 21
“which is proposed based on muscle synergy [14], [15].”
BackgroundEngdahl, S. M., Dhawan, A. S., Bashatah, A., Diao, G., Mukherjee, B., Monroe, B., Holley, R. J., & Sikdar, S. (2022) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2022.3140973 · Cited by 21
e-Health: Biomedical instrumentation with Arduino
Méndez, S. T. P., Úbeda, A., & Torres, F. (2017) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2017.08.1724 · Cited by 21
Lobo-Prat, J., Nizamis, K., Janssen, M., Keemink, A., Veltink, P., Koopman, B., & Stienen, A. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0282-6 · Cited by 15
“In upper extremity prosthetic applications, more advanced sEMG-based control methods such as regression-based algorithms have shown simultaneous and proportional control over two DOF with sEMG signals [37] and three DOF with intramuscular EMG signals [29].”
MethodCole, N. M., & Ajiboye, A. B. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab2d47 · Cited by 20
“A major challenge for designing neuroprosthetic devices is the limited availability of voluntary command signals, such as residual myoelectric inputs, for coordinating the many DoFs of the hand.”
BackgroundInfluentialRealizing Efficient EMG-Based Prosthetic Control Strategy
Li, G., Samuel, O. W., Lin, C., Asogbon, M. G., Fang, P., & Idowu, O. P. (2019) · Advances in experimental medicine and biology · doi:10.1007/978-981-13-2050-7_6 · Cited by 20
Robust Continuous Hand Motion Recognition Using Wearable Array Myoelectric Sensor
Hu, X., Zeng, H., Song, A., & Chen, D. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3098120 · Cited by 20
Pan, L., Crouch, D. L., & Huang, H. (2017) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2017.8008356 · Cited by 19
Pradhan, A., Jiang, N., Chester, V. L., & Kuruganti, U. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.101984 · Cited by 19
Self-citationCampbell, E., Egle, F., Oßwald, M., Côté‐Allard, U., Pilarski, P. M., Boccardo, N., Meattini, R., Vujaklija, I., Hargrove, L. J., Canepa, M., et al. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3602397 · Cited by 18
“Bio-inspired regression-based techniques create a continuous mapping between EMG signals and estimated user intentions [45].”
Self-citationLi, X., Tian, L., Zheng, Y., Samuel, O. W., Fang, P., Wang, L., & Li, G. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102969 · Cited by 18
Frequency-Domain sEMG Classification Using a Single Sensor
Stefanou, T., Guiraud, D., Fattal, C., Coste, C., & da Fonseca, L. O. (2022) · Sensors · doi:10.3390/s22051939 · Cited by 18
Continuous Kalman Estimation Method for Finger Kinematics Tracking from Surface Electromyography
Zhang, H., Peng, B., Tian, L., Samuel, O. W., & Li, G. (2024) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0094 · Cited by 17
“The concept of proportional control inspired by muscle synergy has been introduced for robotic control involving two or three DOFs [7,8], but its current application has been limited to wrist tracking.”
BackgroundMagnetic-based detection of muscular contraction for controlling hand prosthesis
Prakash, A., Sharma, N., Katiyar, A. K., Dubey, S. K., & Sharma, S. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.113709 · Cited by 17
A Comprehensive Review of Myoelectric Prosthesis ControlPreprint
Mohebbian, M. R., Nosouhi, M., Fazilati, F., Esfahani, Z. N., Amiri, G., Malekifar, N., Yusefi, F., Rastegari, M., & Marateb, H. R. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2112.13192 · Cited by 20
Bridging Human-Robot Co-Adaptation via Biofeedback for Continuous Myoelectric Control
Hu, X., Song, A., Zeng, H., Wei, Z., Deng, H., & Chen, D. (2023) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2023.3330053 · Cited by 16
Comparison of hand and forearm muscle pairs in controlling of a novel myoelectric interface
Barnes, J., Dyson, M., & Nazarpour, K. (2016) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2016.7844671 · Cited by 16
“Towards this vision, many research studies have demonstrated the ability to reconstruct both wrist [8], [9] as well as finger movement trajectories [10]–[13] by using regression rather than classification.”
MethodJaquier, N., Connan, M., Castellini, C., & Calinon, S. (2017) · Technologies · doi:10.3390/technologies5040064 · Cited by 16
A Synergy-Based Motor Control Framework for the Fast Feedback Control of Musculoskeletal Systems
Razavian, R. S., Ghannadi, B., & McPhee, J. (2018) · Journal of Biomechanical Engineering · doi:10.1115/1.4042185 · Cited by 16
Transfer of mode switching performance: from training to upper-limb prosthesis use
Heerschop, A., van der Sluis, C. K., & Bongers, R. M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00878-4 · Cited by 16
Individual finger classification from surface EMG: Influence of electrode set
Celadon, N., Dosen, S. S., Paleari, M., Farina, D., & Ariano, P. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7320073 · Cited by 16
Self-citationEMG-Controlled Non-Anthropomorphic Hand Teleoperation Using a Continuous Teleoperation Subspace
Meeker, C., & Ciocarlie, M. (2019) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2019.8794108 · Cited by 16
“Studies which control more than one DOF usually control the wrist, often in a continuous and proportional manner [13][14][15][16].”
BackgroundZhu, Z., Martinez-Luna, C., Li, J., McDonald, B. E., Dai, C., Huang, X., Farrell, T. R., & Clancy, E. A. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3038322 · Cited by 16
“supervision are also emerging, including nonnegative matrix factorization [28], [29] and population-based assignment of”
BackgroundUse of probabilistic weights to enhance linear regression myoelectric control
Smith, L. H., Kuiken, T. A., & Hargrove, L. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/6/066030 · Cited by 15
“Both linear (Hahne et al., 2014, Jiang et al., 2014b, Smith et al., 2015a) and nonlinear (Jiang et al., 2012, Hahne et al., 2014, Kamavuako et al., 2012, Ameri et al., 2014, Ngeo et al., 2014, Muceli and Farina, 2012) methods of mapping EMG activity to prosthesis movement have been evaluated,…”
BackgroundMethodInfluentialTolooshams, B., & Jiang, N. (2017) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2017.00003 · Cited by 15
“A goal-directed motor task involving wrist contractions were used, similar to several previous studies (Ameri et al., 2014a,b; Jiang et al., 2014a,b,c) of multi-DoF real-time myoelectric control.”
BackgroundMethodSelf-citationPreliminary results toward a naturally controlled multi-synergistic prosthetic hand
Rossi, M., Santina, C. D., Piazza, C., Grioli, G., Catalano, M. G., & Bicchi, A. (2017) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2017.8009437 · Cited by 15
Hierarchical Graphical Models for Context-Aware Hybrid Brain-Machine Interfaces
Özdenizci, O., Günay, S. Y., Quivira, F., & Erdogmus, D. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512677 · Cited by 15
Toward Impedance Control in Human–Machine Interfaces for Upper-Limb Prostheses
Ferrante, L., Sridharan, M., Zito, C., & Farina, D. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3384340 · Cited by 14
Self-citationDeep Feature Learning From Electromyographic Signals for Gesture Recognition Systems
Zhong, W., Jiang, X., Szymaniak, K., Jabbari, M., Ma, C., & Nazarpour, K. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3635419 · Cited by 14
“Previous research has shown that o ffl ine assessments often do not reflect real-world conditions, as they overlook user adaptive behaviors in response to non-stationarity of the EMG signal [184], [185], [186], [187], [188], [189], [190].”
Teng, Z., Xu, G., Liang, R., Li, M., & Zhang, S. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3124744 · Cited by 14
Cho, Y., Kim, P., & Kim, K.-S. (2020) · IEEE Access · doi:10.1109/access.2020.3012741 · Cited by 14
“Previous research succeeded in estimating the motion of individual fingers proportionally using-modified non-negative matrix factorization (NMF), which is a semi-unsupervised learning method [18], [19].”
MethodIncremental Learning of Muscle Synergies: From Calibration to Interaction
Castellini, C. (2016) · Springer series on touch and haptic systems · doi:10.1007/978-3-319-26706-7_11 · Cited by 14
Wang, Z., Wang, H., Bi, Z.-Y., Zhou, Y. C., Zhou, Y., & Lv, X. (2016) · Neural Regeneration Research · doi:10.4103/1673-5374.197139 · Cited by 14
“Therefore, methods such as non-negative matrix factorization (Jiang et al., 2009, 2014) for extracting time-invariant synergies in multi-channel sEMG and multipad electrode surface stimulation system (Malešević et al., 2012; Popović-Maneski et al., 2013) are needed to realize multi-degree of…”
MethodŠavc, M., Glaser, V., Kranjec, J., Cikajlo, I., Matjačić, Z., & Holobar, A. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2869426 · Cited by 14
“during isometric [22] and dynamic contractions [23], [24].”
BackgroundA novel energy-motion model for continuous sEMG decoding: from muscle energy to motor pattern
Liu, G., Wang, L., & Wang, J. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abbece · Cited by 13
How Many Muscles? Optimal Muscles Set Search for Optimizing Myocontrol Performance
Camardella, C., Junata, M., Tse, K. C., Frisoli, A., & Tong, R. K. (2021) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2021.668579 · Cited by 13
An optoelectronic muscle contraction sensor for prosthetic hand application
Sharma, N., Prakash, A., & Sharma, S. (2023) · Review of Scientific Instruments · doi:10.1063/5.0130394 · Cited by 13
Human Movements Classification Using Multi-channel Surface EMG Signals and Deep Learning Technique
Zhang, J., Ling, C., & Li, S. (2019) · International Conference on Cyberworlds (CW) · doi:10.1109/cw.2019.00051 · Cited by 13
“The EMG pattern recognition algorithm can be applied to prosthesis control of patients with amputated limbs [2-5].”
MethodDimensionality analysis of forearm muscle activation for myoelectric control in transradial amputees
McClanahan, A. J., Moench, M., & Fu, Q. (2020) · PLoS ONE · doi:10.1371/journal.pone.0242921 · Cited by 13
Towards low-dimensionsal proportional myoelectric control
Krasoulis, A., Nazarpour, K., & Vijayakumar, S. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7320042 · Cited by 14
“[3] used a muscle synergy model based on non-negative matrix factorization (NMF) to decode wrist kinematics during real-time experiments with amputee subjects.”
BackgroundMethodBala, S., Vishnu, V. Y., & Joshi, D. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3431024 · Cited by 12
“In the following analyses the subjects were a random factor and were pooled together [47].”
MethodInfluentialCady, S. R., Lambrecht, J. M., Dsouza, K. T., Dunning, J. L., Anderson, J. R., Malone, K. J., Chepla, K. J., Graczyk, E. L., & Tyler, D. J. (2025) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-025-01613-z · Cited by 13
“…simultaneous nerve stimulation and myoelectric recording to support bidirectional control in a non‑percutaneous interface S01’s 3 DOF controller time-to-target in the virtual environment matched previously published trial durations for myoelectric controllers with multiple DOFs [14, 16, 69– 71].”
Precise Control Method on Prosthetic Hand Using sEMG Signals
Orban, M., Zhang, X., Lu, Z., Marcal, A., Emad, A., & Masengo, G. (2020) · IEEE International Conference on Cyber Technology in Automation, Control, and Intelligent Systems · doi:10.1109/cyber50695.2020.9279179 · Cited by 12
“proposed a new control strategy depends on a method called (NMF) Non-negative Matrix Factorization that allows the proportional and simultaneous control for 2 DOF in specific extension /flexion and prono/supination of the wrist, while it needs for initial calibration the success rate was around 95% although this high…”
MethodConstrained particle filtering for movement identification in forearm prosthesis
Amor, N., Rasool, G., Bouaynaya, N. C., & Shterenberg, R. (2019) · Signal Processing · doi:10.1016/j.sigpro.2019.03.012 · Cited by 12
Malešević, N., Björkman, A., Andersson, G. S., Cipriani, C., & Antfolk, C. (2022) · Sensors · doi:10.3390/s22135054 · Cited by 11
Discrete Action Control for Prosthetic Digits
Krasoulis, A., & Nazarpour, K. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3157710 · Cited by 11
Biorealistic hand prosthesis with compliance control and noninvasive somatotopic sensory feedback
Lan, N., Zhang, J., Zhang, Z., Chou, C.-H., Rymer, W. Z., Niu, C. M., & Fang, P. (2023) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/acc625 · Cited by 11
“The SPC approaches also include the use of artificial neural networks for joint kinematics predictions during upper-limb movements [47], analysis of the muscle synergies underlying a range of upper-limb movements [48], as well as the muscle synergy driven by nonnegative matrix factorization [49].”
Adaptive common average filtering for myocontrol applications
Rehbaum, H., & Farina, D. (2014) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-014-1215-1 · Cited by 11
“For a detailed description, see [11, 18]”
Self-citationKim, P., Kim, K.-S., & Kim, S. (2015) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2015.7354086 · Cited by 10
“researchers have employed the envelope of the signal as the input of a model [7, 10, 11, 17, 21].”
MethodZhao, K., Zhang, Z., Wen, H., & Scano, A. (2022) · Physiological Measurement · doi:10.1088/1361-6579/ac9773 · Cited by 10
“…(Tresch et al 1999, d’Avella et al 2003, Ting andMcKay 2007), physiological biomarkers for clinical assessment and rehabilitative treatment (Cheung et al 2012, Roh et al 2015, Pan et al 2018), and prostheses control (Jiang et al 2014, Lunardini et al 2016)have been demonstrated in several studies.”
BackgroundNgeo, J., Tamei, T., Ikeda, K., & Shibata, T. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318801 · Cited by 11
Davarinia, F., & Maleki, A. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102740 · Cited by 9
A three degrees of freedom switchable impedance myoelectric prosthetic wrist
Capsi‐Morales, P., Piazza, C., Grioli, G., Bicchi, A., & Catalano, M. G. (2024) · The International Journal of Robotics Research · doi:10.1177/02783649241231298 · Cited by 9
“Control strategies adopted for multi-digit hands in the clinic (Cipriani et al., 2011; Dalley et al., 2009; Weir et al., 2008) and the market (Belter et al., 2013) were also used for hand – wrist combinations (Jiang et al. 2012, 2014; Piazza et al., 2020; Young et al., 2013).”
A multifaceted suite of metrics for comparative myoelectric prosthesis controller research
Williams, H. E., Shehata, A. W., Cheng, K. Y., Hebert, J. S., & Pilarski, P. M. (2024) · PLoS ONE · doi:10.1371/journal.pone.0291279 · Cited by 9
Muscle Synergy during Wrist Movements Based on Non-Negative Tucker Decomposition
Chen, X., Feng, Y., Chang, Q., Yu, J., Chen, J., & Xie, P. (2024) · Sensors · doi:10.3390/s24103225 · Cited by 9
“The existing methods for muscle synergy are largely achieved by applying matrix factorization to surface electromyography (sEMG) data, which are decomposed into some matrices with spatial and temporal patterns [8,9].”
MethodFoot Gesture Recognition with Flexible High-Density Device Based on Convolutional Neural Network
Lin, C., Tang, Y., Yong, Z., Zhang, K., Fan, Z., Yang, Y., Leng, Y., & Fu, C. (2021) · International Conference on Advanced Robotics and Mechatronics (ICARM) · doi:10.1109/icarm52023.2021.9536141 · Cited by 9
Yu, Y., Chen, C., Sheng, X., & Zhu, X. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8716941 · Cited by 9
“Specifically, a series of work [5], [6]”
Wang, Z., Wang, H., Bi, Z.-Y., Zhou, Y., Zhou, Y., & Lv, X.-Y. (2017) · Neural Regeneration Research · doi:10.4103/1673-5374.199216 · Cited by 9
On the use of higher-order tensors to model muscle synergies
Ebied, A., Spyrou, L., Kinney‐Lang, E., & Escudero, J. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8037192 · Cited by 8
“X(m×n) = S(m×r) × W(r×n) (2) The most widely used matrix factorisation techniques for synergy estimation is the NMF [7].”
BackgroundMethodInfluentialChen, C., Yu, Y., Sheng, X., & Zhu, X. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176362 · Cited by 8
“Consequently, several myoelectric control strategies have been proposed such as state machine [2], pattern recognition [3], and proportional control [4].”
BackgroundVujaklija, I., & Farina, D. (2022) · Springer eBooks · doi:10.1007/978-3-031-10355-1_41 · Cited by 8
Self-citationFingertip Proximity-Based Grasping Pattern Prediction of Transradial Myoelectric Prosthesis
Yang, B., Shi, C., Liu, Z., Hu, Y., Cheng, M., & Li, J. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2023.3247580 · Cited by 8
Forearm Muscle Synergy Reducing Dimension of the Feature Matrix in Hand Gesture Recognition
Luo, X. Y., Wu, X. Y., Chen, L., Hu, N., Zhang, Y., Yun, Z., Hu, L. T., Yang, D., Hou, W., Wu, X. Y., et al. (2018) · International Conference on Advanced Robotics and Mechatronics (ICARM) · doi:10.1109/icarm.2018.8610832 · Cited by 8
“[8, 9] established the sEMG generation model to extract the control information according to muscle synergy principle, and NMF was used to extract the synergistic muscle activity to build low-dimensional control signals.”
MethodEbied, A., Kinney‐Lang, E., & Escudero, J. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8717076 · Cited by 8
“Moreover, the performance of proportional myoelectric control based on NMF synergies degrades significantly with the of increase task-space dimension into 3 degree of freedoms (DoF) of movement [6], [8].”
BackgroundMethodInfluentialPan, L., Harmody, A., & Huang, H. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512685 · Cited by 8
“[1, 4-9].”
Control interfaces to actively support the arm function of men with Duchenne Muscular Dystrophy
Lobo-Prat, J. (2016) · doi:10.3990/1.9789036541701 · Cited by 7
Wrist autonomy based on upper-limb synergy: a pilot study
Peng, C., Yang, D., Ge, Z., & Liu, H. (2023) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-023-02783-5 · Cited by 7
Enhanced myoelectric control against arm position change with weighted recursive Gaussian process
Jung, M. C., Chai, R., Zheng, J., & Nguyen, H. T. (2021) · Neural Computing and Applications · doi:10.1007/s00521-021-05743-y · Cited by 7
“In the literature, the connection between offline performance and real-time performance is clear in some methods and unclear in other methods [8, 18, 24, 30, 40, 41].”
BackgroundResultHigher order tensor decomposition for proportional myoelectric control based on muscle synergies
Ebied, A., Kinney‐Lang, E., & Escudero, J. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102523 · Cited by 7
Zhang, S., Lu, J., Huo, W., Yu, N., & Han, J. (2022) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2022.978014 · Cited by 7
“…which is widely accepted as a constitutional function unit of the central neural systems that control muscles in groups (d’Avella et al., 2003; Jiang et al., 2014; Dwivedi et al., 2020; Kubota et al., 2021), a group of related muscles’ activities have certain common components or patterns,…”
BackgroundPan, L., & Huang, H. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102509 · Cited by 7
Upper Limb Joint Angular Velocity Synergies of Human Reaching Movements
Tang, S., Barsotti, M., Stroppa, F., Frisoli, A., Wu, X., & Hou, W. (2018) · IEEE International Conference on Cyborg and Bionic Systems (CBS) · doi:10.1109/cbs.2018.8612235 · Cited by 7
Musculoskeletal Modeling Based on Muscle Synergy for Prediction of Hand and Wrist Movements
Pan, L., Li, Q., & Li, J. (2024) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2024.3503920 · Cited by 6
“…from EMG signals mainly with regression algorithms, such as linear regression (LR) models [15], artificial neural networks (ANNs) [16], [17], Gaussian Process (GP) regression models [18], non-negative matrix factorization (NMF) algorithms [19], and deep learning meth-ods [20], [21], [22].”
Real-time myoelectric control of wrist/hand motion in Duchenne muscular dystrophy: A case study
Nizamis, K., Ayvaz, A., Rijken, N. H. M., Koopman, H. F. J. M., & Sartori, M. (2023) · Frontiers in Robotics and AI · doi:10.3389/frobt.2023.1100411 · Cited by 6
sEMG-Based Gesture Classifier Through DTW and Enhanced Muscle Activity Detection
Chaves, G. S., Vieira, A. S., & Lima, M. V. S. (2024) · IEEE Access · doi:10.1109/access.2024.3448410 · Cited by 6
“In addition to being non-intrusive, a major advantage of sEMG sensors is their easiness of operation, which allows the existence of many simple and reliable commercial devices [11], [12], [13].”
Background
Metadata
- Authors
- Jiang, N., Rehbaum, H., Vujaklija, I., Graimann, B., & Farina, D.
- Affiliations
- Bernstein Center for Computational Neuroscience Göttingen (DE)
- Ottobock (Germany) (DE)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2014-05
- Volume
- 22
- Issue
- 3
- Pages
- 501-510
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2100338757
- Cited by
- 269
- References
- 22
- Citations by year
- 2026: 5 · 2025: 11 · 2024: 16 · 2023: 15 · 2022: 22 · 2021: 28 · 2020: 32 · 2019: 30 · 2018: 21 · 2017: 31 · 2016: 16 · 2015: 23 · 2014: 17
- FWCI
- 10.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- GRO (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- myoelectric control, upper limb amputees, two-degree-of-freedom control, surface electromyography, non-negative matrix factorization, proportional control, myoelectric prosthesis
- MeSH terms
- Adolescent, Adult, Aged, Algorithms, Amputation, Surgical, Amputees, Artificial Limbs, Biomechanical Phenomena, Calibration, Electromyography, Humans, Male, Middle Aged, Online Systems, Wrist, Upper Extremity, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.