Simultaneous Neural Control of Simple Reaching and Grasping With the Modular Prosthetic Limb Using Intracranial EEG
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Intracranial electroencephalographic (iEEG) signals from two human subjects were used to achieve simultaneous neural control of reaching and grasping movements with the Johns Hopkins University Applied Physics Lab (JHU/APL) Modular Prosthetic Limb (MPL), a dexterous robotic prosthetic arm. We performed functional mapping of high gamma activity while the subject made reaching and grasping movements to identify task-selective electrodes. Independent, online control of reaching and grasping was then achieved using high gamma activity from a small subset of electrodes with a model trained on short blocks of reaching and grasping with no further adaptation. Classification accuracy did not decline (p < 0.05, one-way ANOVA) over three blocks of testing in either subject. Mean classification accuracy during independently executed overt reach and grasp movements for (Subject 1, Subject 2) were (0.85, 0.81) and (0.80, 0.96), respectively, and during simultaneous execution they were (0.83, 0.88) and (0.58, 0.88), respectively. Our models leveraged knowledge of the subject's individual functional neuroanatomy for reaching and grasping movements, allowing rapid acquisition of control in a time-sensitive clinical setting. We demonstrate the potential feasibility of verifying functionally meaningful iEEG-based control of the MPL prior to chronic implantation, during which additional capabilities of the MPL might be exploited with further training.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848 · cited 1×
“Although iEEG macroelectrodes [13], [14], iEEG microelectrodes [39], and multi-electrode arrays [40], [41] have all been used to demonstrate effective BMI control in small populations, no large-scale longitudinal studies have compared the tissue response and control performance between these classes of implants.”
BackgroundThe organization of the cortical motor system: new concepts
Rizzolatti, G., Luppino, G., & Matelli, M. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00022-4 · Cited by 1,127
Different Origins of Gamma Rhythm and High-Gamma Activity in Macaque Visual Cortex
Ray, S., & Maunsell, J. H. R. (2011) · PLoS Biology · doi:10.1371/journal.pbio.1000610 · Cited by 1,012
Electroencephalographic (EEG) control of three-dimensional movement
McFarland, D. J., Sarnacki, W. A., & Wolpaw, J. R. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/3/036007 · Cited by 454
Signal quality of simultaneously recorded invasive and non-invasive EEG
Ball, T., Kern, M., Mutschler, I., Aertsen, A., & Schulze-Bonhage, A. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.028 · Cited by 403
Filimon, F. (2010) · The Neuroscientist · doi:10.1177/1073858410375468 · Cited by 265
Electrocorticographic control of a prosthetic arm in paralyzed patients
Yanagisawa, T., Hirata, M., Saitoh, Y., Kishima, H., Matsushita, K., Goto, T., Fukuma, R., Yokoi, H., Kamitani, Y., & Yoshimine, T. (2012) · Annals of Neurology · doi:10.1002/ana.22613 · Cited by 256 · cited 3×
“A large amount of decoding and BMI success has been achieved using command signals derived from iEEG [6], [7], [13], [14], [38].”
BackgroundMethodReal-time control of a prosthetic hand using human electrocorticography signals: Technical note
Yanagisawa, T., Hirata, M., Saitoh, Y., Goto, T., Kishima, H., Fukuma, R., Yokoi, H., Kamitani, Y., & Yoshimine, T. (2011) · Journal of Neurosurgery · doi:10.3171/2011.1.jns101421 · Cited by 208 · cited 2×
“A large amount of decoding and BMI success has been achieved using command signals derived from iEEG [6], [7], [13], [14], [38].”
BackgroundMethodFifer, M. S., Acharya, S., Benz, H. L., Mollazadeh, M., Crone, N. E., & Thakor, N. V. (2012) · IEEE Pulse · doi:10.1109/mpul.2011.2175636 · Cited by 74 · cited 1×
“which allow pre-programmed hand grasp patterns to be actuated in a coordinated fashion as a single degree of freedom [23], [24].”
BackgroundSelf-citation
Cited by
A comprehensive review of EEG-based brain–computer interface paradigms
Abiri, R., Borhani, S., Sellers, E. W., Jiang, Y., & Zhao, X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf12e · Cited by 946
Hotson, G., McMullen, D. P., Fifer, M. S., Johannes, M. S., Katyal, K. D., Para, M. P., Armiger, R., Anderson, W. S., Thakor, N. V., Wester, B. A., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026017 · Cited by 201
“a prosthetic limb was demonstrated with mean accuracies of 84% and 81% for reach and grasp respectively [12].”
BackgroundMethodSelf-citationHuman brain mapping with multithousand-channel PtNRGrids resolves spatiotemporal dynamics
Tchoe, Y., Bourhis, A. M., Cleary, D. R., Stedelin, B., Lee, J., Tonsfeldt, K. J., Brown, E. C., Siler, D. A., Paulk, A. C., Yang, J. C., et al. (2022) · Science Translational Medicine · doi:10.1126/scitranslmed.abj1441 · Cited by 135
Systems Neuroengineering: Understanding and Interacting with the Brain
Edelman, B. J., Johnson, N., Sohrabpour, A., Tong, S., Thakor, N., & He, B. (2015) · Engineering · doi:10.15302/j-eng-2015078 · Cited by 45
“These systems are thus able to detect individual finger activity as well as kinematic information of the arm, and have shared in the success of controlling prosthetic devices [97].”
BackgroundSelf-citation
Metadata
- Authors
- Fifer, M. S., Hotson, G., Wester, B. A., McMullen, D. P., Wang, Y., Johannes, M. S., Katyal, K. D., Helder, J. B., Para, M. P., Vogelstein, R. J., Anderson, W. S., Thakor, N. V., & Crone, N. E.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2014-05
- Volume
- 22
- Issue
- 3
- Pages
- 695-705
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W1969010174
- Cited by
- 88
- References
- 10
- FWCI
- 3.53
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous Neural Control of Simple Reaching and Grasping With the Modular Prosthetic Limb Using Intracranial EEG. https://app.cochat.ai/papers/10.1109/tnsre.2013.2286955
- The paper
- Fifer, M. S., Hotson, G., Wester, B. A., McMullen, D. P., Wang, Y., Johannes, M. S., Katyal, K. D., Helder, J. B., Para, M. P., Vogelstein, R. J., Anderson, W. S., Thakor, N. V., & Crone, N. E. (2014). Simultaneous Neural Control of Simple Reaching and Grasping With the Modular Prosthetic Limb Using Intracranial EEG. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2013.2286955
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.