CoChat

Improving Cochlear Implant Properties Through Conductive Hydrogel Coatings

Hassarati, Rachelle T., Dueck, Wolfram F., Tasche, Claudia, Carter, Paul M., Poole-Warren, Laura A., Green, Rylie A. · 2014 · IEEE Transactions on Neural Systems and Rehabilitation Engineering
Cited by 80

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Conductive hydrogel (CH) coatings for biomedical electrodes have shown considerable promise in improving electrode mechanical and charge transfer properties. While they have desirable properties as a bulk material, there is limited understanding of how these properties translate to a microelectrode array. This study evaluated the performance of CH coatings applied to Nucleus Contour Advance cochlear electrode arrays. Cyclic voltammetry and biphasic stimulation were carried out to determine electrical properties of the coated arrays. Electrical testing demonstrated that CH coatings supported up to 24 times increase in charge injection limit. Reduced impedance was also maintained for over 1 billion stimulations without evidence of delamination or degradation. Mechanical studies performed showed negligible effect of the coating on the pre-curl structure of the Contour Advance arrays. Testing the coating in a model human scala tympani confirmed that adequate contact was maintained across the lateral wall. CH coatings are a viable, stable coating for improving electrical properties of the platinum arrays while imparting a softer material interface to reduce mechanical mismatch. Ultimately, these coatings may act to minimize scar tissue formation and fluid accumulation around electrodes and thus improve the electrical performance of neural implants.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2014.2304559

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 80

Metadata

Authors
Hassarati, R. T., Dueck, W. F., Tasche, C., Carter, P. M., Poole-Warren, L. A., & Green, R. A.
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2014-03
Volume
22
Issue
2
Pages
411-418
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W1966811594
Cited by
80
References
11
FWCI
2.95
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improving Cochlear Implant Properties Through Conductive Hydrogel Coatings. https://app.cochat.ai/papers/10.1109/tnsre.2014.2304559
The paper
Hassarati, R. T., Dueck, W. F., Tasche, C., Carter, P. M., Poole-Warren, L. A., & Green, R. A. (2014). Improving Cochlear Implant Properties Through Conductive Hydrogel Coatings. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2014.2304559

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.