Simulating Transcranial Direct Current Stimulation With a Detailed Anisotropic Human Head Model
The DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
Transcranial direct current stimulation (tDCS) is a noninvasive brain stimulation technique able to induce long-lasting changes in cortical excitability that can benefit cognitive functioning and clinical treatment. In order to both better understand the mechanisms behind tDCS and possibly improve the technique, finite element models are used to simulate tDCS of the human brain. With the detailed anisotropic head model presented in this study, we provide accurate predictions of tDCS in the human brain for six of the practically most-used setups in clinical and cognitive research, targeting the primary motor cortex, dorsolateral prefrontal cortex, inferior frontal gyrus, occipital cortex, and cerebellum. We present the resulting electric field strengths in the complete brain and introduce new methods to evaluate the effectivity in the target area specifically, where we have analyzed both the strength and direction of the field. For all cerebral targets studied, the currently accepted configurations produced sub-optimal field strengths. The configuration for cerebellum stimulation produced relatively high field strengths in its target area, but it needs higher input currents than cerebral stimulation does. This study suggests that improvements in the effects of transcranial direct current stimulation are achievable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970
Nitsche, M. A., & Paulus, W. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00633.x · Cited by 5,656
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270
The dielectric properties of biological tissues: I. Literature survey
Gabriel, C., Gabriel, S., & Corthout, E. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/001 · Cited by 3,156
Characterization and propagation of uncertainty in diffusion-weighted MR imaging
Behrens, T. E. J., Woolrich, M. W., Jenkinson, M., Johansen‐Berg, H., Nunes, R. G., Clare, S., Matthews, P. M., Brady, J. M., & Smith, S. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10609 · Cited by 3,038
Sustained excitability elevations induced by transcranial DC motor cortex stimulation in humans
Nitsche, M. A., & Paulus, W. (2001) · Neurology · doi:10.1212/wnl.57.10.1899 · Cited by 2,617
A Multiphase Level Set Framework for Image Segmentation Using the Mumford and Shah Model
Vese, L. A., & Chan, T. F. (2002) · International Journal of Computer Vision · doi:10.1023/a:1020874308076 · Cited by 2,384
A signal processing approach to fair surface design
Taubin, G. (1995) · Proceedings of the 22nd annual conference on Computer graphics and interactive techniques - SIGGRAPH '95 · doi:10.1145/218380.218473 · Cited by 1,855
Datta, A., Bansal, V., Diaz, J., Patel, J., Reato, D., & Bikson, M. (2009) · Brain Stimulation · doi:10.1016/j.brs.2009.03.005 · Cited by 1,290
The B‐matrix must be rotated when correcting for subject motion in DTI data
Leemans, A., & Jones, D. K. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21890 · Cited by 1,281
Cited by
A technical guide to tDCS, and related non-invasive brain stimulation tools
Woods, A. J., Antal, A., Bikson, M., Boggio, P. S., Brunoni, A. R., Celnik, P., Cohen, L. G., Fregni, F., Herrmann, C. S., Kappenman, E. S., et al. (2016) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.11.012 · Cited by 1,439
Safety of Transcranial Direct Current Stimulation: Evidence Based Update 2016
Bikson, M., Grossman, P., Thomas, C., Zannou, A. L., Jiang, J., Adnan, T., Mourdoukoutas, A. P., Kronberg, G., Truong, D., Boggio, P., et al. (2016) · Brain Stimulation · doi:10.1016/j.brs.2016.06.004 · Cited by 1,396
Antal, A., Alekseichuk, I., Bikson, M., Brockmöller, J., Brunoni, A. R., Chen, R., Cohen, L. G., Dowthwaite, G., Ellrich, J., Flöel, A., et al. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.06.001 · Cited by 1,301
Siebner, H. R., Funke, K., Aberra, A. S., Antal, A., Bestmann, S., Chen, R., Classen, J., Davare, M., Di Lazzaro, V., Fox, P. T., et al. (2022) · Clinical Neurophysiology · doi:10.1016/j.clinph.2022.04.022 · Cited by 566
Consensus Paper: Cerebellum and Social Cognition
Van Overwalle, F., Manto, M., Cattaneo, Z., Clausi, S., Ferrari, C., Gabrieli, J. D. E., Guell, X., Heleven, E., Lupo, M., Ma, Q., et al. (2020) · The Cerebellum · doi:10.1007/s12311-020-01155-1 · Cited by 442
Grimaldi, G., Argyropoulos, G. P., Bastian, A., Cortes, M., Davis, N. J., Edwards, D. J., Ferrucci, R., Fregni, F., Galea, J. M., Hamada, M., et al. (2016) · The Neuroscientist · doi:10.1177/1073858414559409 · Cited by 230
Summers, J. J., Kang, N., & Cauraugh, J. H. (2016) · Ageing Research Reviews · doi:10.1016/j.arr.2015.11.004 · Cited by 184
“In terms of site of stimulation, moderate effect sizes were evident for stimulation of the DLPFC (mean effect size = 0.39) and other non-motor sites (mean effect size = 0.52).”
InfluentialPhase Entrainment of Brain Oscillations Causally Modulates Neural Responses to Intelligible Speech
Zoefel, B., Archer-Boyd, A., & Davis, M. H. (2018) · Current Biology · doi:10.1016/j.cub.2017.11.071 · Cited by 183
Elsner, B., Kwakkel, G., Kugler, J., & Mehrholz, J. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0301-7 · Cited by 171
“In popular electrode settings most of the current is redirected by the skin covering the skull, hence being unable to ‘trigger’ neurons effectively [14].”
Prospects for transcranial temporal interference stimulation in humans: A computational study
Rampersad, S., Roig-Solvas, B., Yarossi, M., Kulkarni, P. P., Santarnecchi, E., Dorval, A. D., & Brooks, D. H. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116124 · Cited by 166
Self-citationVan Hoornweder, S., Nuyts, M., Frieske, J., Verstraelen, S., Meesen, R. L. J., & Caulfield, K. A. (2023) · doi:10.1101/2023.02.22.529540 · Cited by 37
“R eg io n of In te re st Cylinder Average 1 1 [10, 20] Percentile 1 [20] Cube Average 2 [19, 45] Percentile 1 [46] Sphere Average 16 13 [4, 6, 11, 17, 18, 22, 26, 30, 44, 47-64] Percentile 3 1 [11, 21, 65]”
Background
Metadata
- Authors
- Rampersad, S. M., Janssen, A. M., Lucka, F., Aydin, U., Lanfer, B., Lew, S., Wolters, C. H., Stegeman, D. F., & Oostendorp, T. F.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2014-05
- Volume
- 22
- Issue
- 3
- Pages
- 441-452
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2138150447
- Cited by
- 206
- References
- 62
- FWCI
- 8.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.