CoChat

Effects of Locomotion Mode Recognition Errors on Volitional Control of Powered Above-Knee Prostheses

Open access
Zhang, Fan, Liu, Ming, Huang, He · 2015 · IEEE Transactions on Neural Systems and Rehabilitation Engineering
Cited by 82

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Recent studies have reported various methods that recognize amputees' intent regarding locomotion modes, which is potentially useful for volitional control of powered artificial legs. However, occasional errors in locomotion mode recognition are inevitable. When these intent recognition decisions are used for volitional prosthesis control, the effects of the decision errors on the operation of the prosthesis and user's task performance is unknown. Hence, the goals of this study were to 1) systematically investigate the effects of locomotion mode recognition errors on volitional control of powered prosthetic legs and the user's gait stability, and 2) identify the critical mode recognition errors that impact safe and confident use of powered artificial legs in lower limb amputees. Five able-bodied subjects and two above-knee (AK) amputees were recruited and tested when wearing a powered AK prosthesis. Four types of locomotion mode recognition errors with different duration and at different gait phases were purposely applied to the prosthesis control. The subjects' gait stabilities were subjectively and objectively quantified. The results showed that not all of the mode recognition errors in volitional prosthesis control disturb the subjects' gait stability. The effects of errors on the user's balance depended on 1) the gait phase when the errors happened and 2) the amount of mechanical work change applied on the powered knee caused by the errors. Based on the study results, "critical errors" were defined and suggested as a new index to evaluate locomotion mode recognition algorithms for artificial legs. The outcome of this study might aid the future design of volitionally-controlled powered prosthetic legs that are reliable and safe for practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2014.2327230

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 20

  1. 10.1056/NEJMoa1300126 · DOI · Paper page
  2. 10.1007/s10846-013-9979-3 · DOI
  3. sup, 2009, A powered self-contained knee and ankle prosthesis for near normal gait in transfemoral amputees
  4. hogan, 1985, Impedance control: An approach to manipulation: Part II?Implementation, Trans ASME, 107, 8
  5. leonard, 1995, Gait Analysis Theory and Application
  6. 10.1109/EMBC.2013.6609818 · DOI · Paper page
  7. herr, 2008, Angular momentum in human walking, J Exp Biol, 211, 467, 10.1242/jeb.008573 · DOI · Paper page
  8. 10.1109/ROBOT.2004.1307421 · doi:10.1109/robot.2004.1307421
  9. 10.1093/gerona/53A.2.M126 · DOI
  10. hanavan, 1964, A mathematical model of the human body, 1
  11. 10.1177/0278364907084588 · DOI · Paper page
  12. 10.1682/JRRD.2008.09.0131 · doi:10.1682/jrrd.2008.09.0131
  13. 10.1109/TBME.2009.2034734 · DOI · Paper page
  14. 10.1016/j.neunet.2008.03.006 · DOI · Paper page
  15. 10.1109/TBME.2008.2003293 · DOI · Paper page
  16. 10.1109/JBHI.2012.2236563 · DOI · Paper page
  17. 0, The POWER KNEE
  18. 10.1016/S0003-9993(96)90151-3 · doi:10.1016/s0003-9993(96)90151-3
  19. 10.1016/S0966-6362(02)00010-3 · doi:10.1016/s0966-6362(02)00010-3
  20. nashner, 1980, Balance adjustments of humans perturbed while walking, J Neurophysiol, 44, 650, 10.1152/jn.1980.44.4.650 · DOI · Paper page

Cited by

See all 82

Metadata

Authors
Zhang, F., Liu, M., & Huang, H.
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2015-01
Volume
23
Issue
1
Pages
64-72
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2326837543
Cited by
82
References
1
FWCI
1.82
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.