Characterization of a Benchmark Database for Myoelectric Movement Classification
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
In this paper, we characterize the Ninapro database and its use as a benchmark for hand prosthesis evaluation. The database is a publicly available resource that aims to support research on advanced myoelectric hand prostheses. The database is obtained by jointly recording surface electromyography signals from the forearm and kinematics of the hand and wrist while subjects perform a predefined set of actions and postures. Besides describing the acquisition protocol, overall features of the datasets and the processing procedures in detail, we present benchmark classification results using a variety of feature representations and classifiers. Our comparison shows that simple feature representations such as mean absolute value and waveform length can achieve similar performance to the computationally more demanding marginal discrete wavelet transform. With respect to classification methods, the nonlinear support vector machine was found to be the only method consistently achieving high performance regardless of the type of feature representation. Furthermore, statistical analysis of these results shows that classification accuracy is negatively correlated with the subject's Body Mass Index. The analysis and the results described in this paper aim to be a strong baseline for the Ninapro database. Thanks to the Ninapro database (and the characterization described in this paper), the scientific community has the opportunity to converge to a common position on hand movement recognition by surface electromyography, a field capable to strongly affect hand prosthesis capabilities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breitung, J., & Hamilton, J. D. (1995) · Contemporary Sociology · doi:10.2307/2076916 · Cited by 10,966
Hamilton, J. D. (1994) · Princeton University Press eBooks · doi:10.1515/9780691218632 · Cited by 7,293
Hudak, P. L., Amadio, P. C., Bombardier, C., Beaton, D., Cole, D., Davis, A., Hawker, G., Katz, J. N., Makela, M., Marx, R. G., et al. (1996) · American Journal of Industrial Medicine · doi:10.1002/(sici)1097-0274(199606)29:6<602::aid-ajim4>3.0.co;2-l · Cited by 5,025
A benchmark for the evaluation of RGB-D SLAM systems
Sturm, J., Engelhard, N., Endres, F., Burgard, W., & Cremers, D. (2012) · 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2012.6385773 · Cited by 3,976
SUN database: Large-scale scene recognition from abbey to zoo
Xiao, J., Hays, J., Ehinger, K. A., Oliva, A., & Torralba, A. (2010) · 2010 IEEE Computer Society Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2010.5539970 · Cited by 3,283
(2007) · CaltechAUTHORS (California Institute of Technology) · Cited by 2,274
The PASCAL visual object classes challenge 2006 (VOC2006) results
Everingham, M., Zisserman, A., Williams, C. K. I., & Gool, L. V. (2006) · Cited by 2,223
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
On grasp choice, grasp models, and the design of hands for manufacturing tasks
Cutkosky, M. R. (1989) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.34763 · Cited by 1,513
Cram's introduction to surface electromyography
Criswell, E. E. (2011) · Jones and Bartlett Publishers, Inc. eBooks · Cited by 958
Support Vector Machine-Based Classification Scheme for Myoelectric Control Applied to Upper Limb
Oskoei, M. A., & Hu, H. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.919734 · Cited by 829
Classification of the myoelectric signal using time-frequency based representations
Englehart, K., Hudgins, B., Parker, P. A., & Stevenson, M. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00066-1 · Cited by 645
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 570
A Comparison of Surface and Intramuscular Myoelectric Signal Classification
Hargrove, L. J., Englehart, K., & Hudgins, B. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889192 · Cited by 518
Epidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508
A human-assisting manipulator teleoperated by EMG signals and arm motions
Fukuda, O., Tsuji, T., Kaneko, M., & Otsuka, A. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.808873 · Cited by 483
Smith, L. H., Hargrove, L. J., Lock, B. A., & Kuiken, T. A. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2100828 · Cited by 443
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Influence of anatomical, physical, and detection-system parameters on surface EMG
Farina, D., Cescon, C., & Merletti, R. (2002) · Biological Cybernetics · doi:10.1007/s00422-002-0309-2 · Cited by 373
Decoding of Individuated Finger Movements Using Surface Electromyography
Tenore, F. V. G., Ramos, A., Fahmy, A., Acharya, S., Etienne-Cummings, R., & Thakor, N. V. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005485 · Cited by 342
Building the Ninapro database: A resource for the biorobotics community
Atzori, M., Gijsberts, A., Heynen, S., Hager, A.-G. M., Deriaz, O., van der Smagt, P., Castellini, C., Caputo, B., & Muller, H. (2012) · 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290287 · Cited by 262
Self-citationNielsen, J. L. G., Holmgaard, S., Jiang, N., Englehart, K. B., Farina, D., & Parker, P. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2068298 · Cited by 260
Lucas, M.-F., Gaufriau, A., Pascual, S., Doncarli, C., & Farina, D. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.002 · Cited by 253
Patterns of Static Prehension in Normal Hands
Kamakura, N., Matsuo, M., Ishii, H., Mitsuboshi, F., & Miura, Y. (1980) · The American Journal of Occupational Therapy · doi:10.5014/ajot.34.7.437 · Cited by 249
Objective motor response onset detection in surface myoelectric signals
Staude, G., & Wolf, W. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00067-3 · Cited by 217
The effect of subcutaneous fat on myoelectric signal amplitude and cross-talk
Kuiken, T. A., Lowery, M. M., & Stoykov, N. S. (2003) · Prosthetics & Orthotics International · doi:10.3109/03093640309167976 · Cited by 196
Selective Classification for Improved Robustness of Myoelectric Control Under Nonideal Conditions
Scheme, E. J., Englehart, K. B., & Hudgins, B. S. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2113182 · Cited by 172
Fine detection of grasp force and posture by amputees via surface electromyography
Castellini, C., Gruppioni, E., Davalli, A., & Sandini, G. (2009) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2009.08.008 · Cited by 160
Self-citationFarrell, T. R., & Weir, R. F. F. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.923917 · Cited by 159
Multi-subject/daily-life activity EMG-based control of mechanical hands
Castellini, C., Fiorilla, A. E., & Sandini, G. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-41 · Cited by 155
Self-citationOn the challenge of classifying 52 hand movements from surface electromyography
Kuzborskij, I., Gijsberts, A., & Caputo, B. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347099 · Cited by 126
Self-citationSebelius, F., Rosén, B., & Lundborg, G. (2005) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2005.01.002 · Cited by 125
Real-time classification of electromyographic signals for robotic control
Crawford, B., Miller, K. J., Shenoy, P., & Rao, R. P. N. (2005) · Cited by 115
Learning to Control Opening and Closing a Myoelectric Hand
Bouwsema, H., van der Sluis, C. K., & Bongers, R. M. (2010) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2010.06.025 · Cited by 81
Myocoder studies of multiple myopotential response.
Finley, F. R., & Wirta, R. W. (1967) · PubMed · Cited by 67
Developmental and Functional Hand Grasps
Edwards, S. J., Buckland, D. J., & McCoy-Powlen, J. D. (2002) · Medical Entomology and Zoology · Cited by 66
A reference data set for the evaluation of medical image retrieval systems
Müller, H., Rosset, A., Vallée, J., Terrier, F., & Geissbühler, A. (2004) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2004.04.005 · Cited by 63
Tsuji, T., Ichinobe, H., Ito, K., & Nagamachi, M. (1993) · Transactions of the Society of Instrument and Control Engineers · doi:10.9746/sicetr1965.29.1213 · Cited by 44
The wartenweiler memorial lecture the use of surface electromyography in biomechanics
Luca, C. J. D. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)91124-x · Cited by 39
FFLS: An accurate linear device for measuring synergistic finger contractions
Kõiva, R., Hilsenbeck, B., & Castellini, C. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6345985 · Cited by 36
Self-citationUsing surface electromyography to predict single finger forces
Castellini, C., & Kõiva, R. (2012) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290294 · Cited by 23
Self-citationCompetitive learning method for robust EMG-to-motion classifier
Kato, R., Yokoi, H., & Arai, T. (2006) · International Conference on Intelligent Autonomous Systems · Cited by 20
Cited by
Deep learning for healthcare applications based on physiological signals: A review
Faust, O., Hagiwara, Y., Hong, T. J., Lih, O. S., & Acharya, U. R. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.04.005 · Cited by 1,026
Electromyography data for non-invasive naturally-controlled robotic hand prostheses
Atzori, M., Gijsberts, A., Castellini, C., Caputo, B., Hager, A.-G. M., Elsig, S., Giatsidis, G., Bassetto, F., & Müller, H. (2014) · Scientific Data · doi:10.1038/sdata.2014.53 · Cited by 969
Self-citationAtzori, M., Cognolato, M., & Müller, H. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00009 · Cited by 684
“In 2014, the biggest publicly available benchmark database was released by the NinaPro project (Atzori et al., 2015).”
BackgroundComparison of six electromyography acquisition setups on hand movement classification tasks
Pizzolato, S., Tagliapietra, L., Cognolato, M., Reggiani, M., Müller, H., & Atzori, M. (2017) · PLOS ONE · doi:10.1371/journal.pone.0186132 · Cited by 421
Self-citationEMG Pattern Recognition in the Era of Big Data and Deep Learning
Phinyomark, A., & Scheme, E. (2018) · Big Data and Cognitive Computing · doi:10.3390/bdcc2030021 · Cited by 272
“Ninapro 1 [37] EMG armband 27N (20M 7F) 52 + rest 10 14,040 5 10 100 RMS, LPF at 5 12”
Metadata
- Authors
- Atzori, M., Gijsberts, A., Kuzborskij, I., Elsig, S., Mittaz Hager, A.-G., Deriaz, O., Castellini, C., Muller, H., & Caputo, B.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2015-01
- Volume
- 23
- Issue
- 1
- Pages
- 73-83
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2082480549
- Cited by
- 293
- References
- 43
- FWCI
- 5.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.