Detection of and Compensation for EMG Disturbances for Powered Lower Limb Prosthesis Control
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Myoelectric pattern recognition algorithms have been proposed for the control of powered lower limb prostheses, but electromyography (EMG) signal disturbances remain an obstacle to clinical implementation. To address this problem, we used a log-likelihood metric to detect simulated EMG disturbances and real disturbances acquired from EMG containing electrode shift. We found that features extracted from disturbed EMG have much lower log likelihoods than those from undisturbed signals and can be detected using a single threshold acquired from the training data. We designed a linear discriminant analysis (LDA) classifier that uses the log likelihood to decide between using a combination of EMG and mechanical sensors and using mechanical sensors only, to predict locomotion modes. When EMG contained disturbances, our classifier detected those disturbances and disregarded EMG data. Our classifier had significantly lower errors than a standard LDA classifier in the presence of EMG disturbances. The log-likelihood classifier had a low false positive threshold, and thus did not perform significantly differently from the standard LDA classifier when EMG did not contain disturbances. The log-likelihood threshold could also be applied to individual EMG channels, enabling specific channels containing EMG disturbances to be appropriately ignored when making locomotion mode predictions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, H., Zhang, F., Hargrove, L. J., Dou, Z., Rogers, D. R., & Englehart, K. B. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2161671 · Cited by 542 · cited 3×
“Adding EMG signal information to the information provided by mechanical sensors significantly reduces the error rates of the pattern recognition system and allows prediction of more locomotion modes [10].”
BackgroundMethodResultInfluentialSelf-citation
Research works printed but not linked: 22
- 10.1007/s10439-013-0909-0 · DOI · Paper page
- 10.1016/j.bspc.2007.11.005 · DOI · Paper page
- basmajian, 1985, Their functions revealed by Electromyography
- 10.1109/TNSRE.2009.2023282 · DOI · Paper page
- 10.1109/TITB.2010.2040832 · DOI · Paper page
- 10.1109/TRA.2003.808873 · DOI · Paper page
- du, 2013, Improving the performance of a neural-machine interface for prosthetic legs using adaptive pattern classifiers, Proc 35th Annu Int Conf IEEE Eng Med Biol Soc (EMBC), 1571
- zhang, 0, Real-time implementation of a self-recovery EMG pattern recognition interface for artificial arms, Proc 35th Annu Int Conf IEEE Eng Med Biol Soc (EMBC), 5926
- liu, 0, Trust sensor interface for improving reliability of EMG-based user intent recognition, Proc Annu Int Conf IEEE Eng Med Biol Soc (EMBC), 7516
- 10.1016/j.neunet.2008.03.006 · DOI · Paper page
- 2014, Rheo Knee 3
- 10.1109/TNSRE.2012.2225640 · DOI · Paper page
- 10.1109/BIOROB.2008.4762811 · DOI
- 10.1109/TBME.2009.2034734 · DOI · Paper page
- 10.1007/BF00431022 · DOI · Paper page
- 2013, C-Leg Above-Knee Prosthetic Leg
- 10.1016/j.jelekin.2006.08.006 · DOI · Paper page
- 10.1109/TBME.2008.2003293 · DOI · Paper page
- 10.1177/0278364907084588 · DOI · Paper page
- 10.1109/TBME.2005.856295 · DOI · Paper page
- 10.1109/TNSRE.2010.2087360 · DOI · Paper page
- 10.1088/1741-2560/11/5/056021 · DOI · Paper page
Cited by
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citationA Review on Electromyography Decoding and Pattern Recognition for Human-Machine Interaction
Simao, M., Mendes, N., Gibaru, O., & Neto, P. (2019) · IEEE Access · doi:10.1109/access.2019.2906584 · Cited by 234
Fleming, A., Stafford, N., Huang, S., Hu, X., Ferris, D. P., & Huang, H. (. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac1176 · Cited by 216
“Themost common classification error is between ramps and level-groundwalking [29, 92, 102].”
BackgroundCombined influence of forearm orientation and muscular contraction on EMG pattern recognition
Khushaba, R. N., Al-Timemy, A., Kodagoda, S., & Nazarpour, K. (2016) · Expert Systems with Applications · doi:10.1016/j.eswa.2016.05.031 · Cited by 196
Xu, D., Feng, Y., Mai, J., & Wang, Q. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2870152 · Cited by 67
“sEMG [34], [35].”
Zhu, J., Lei, Y., Shah, A., Schein, G., Ghaednia, H., Schwab, J., Harteveld, C., & Mueller, S. (2022) · Proceedings of the 35th Annual ACM Symposium on User Interface Software and Technology · doi:10.1145/3526113.3545705 · Cited by 40
“from knee replacement), signals captured with EMG are in the same order of magnitude as mechanical noises caused by motion and thus cannot be differentiated from motion artifacts [56].”
BackgroundWhole body awareness for controlling a robotic transfemoral prosthesis
Parri, A., Martini, E., Geeroms, J., Flynn, L., Pasquini, G., Crea, S., Molino Lova, R., Lefeber, D., Kamnik, R., Munih, M., et al. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00025 · Cited by 29
“Frontiers in Neurorobotics | www.frontiersin.org 2 May 2017 | Volume 11 | Article 25 In a recent work by Spanias et al. (2016), the authors built a classifier that, thanks to linear discriminant analysis, is capable to disregard the EMG signals when corrupted by long-term use and switch to…”
BackgroundMethod
Metadata
- Authors
- Spanias, J. A., Perreault, E. J., & Hargrove, L. J.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2016-02
- Volume
- 24
- Issue
- 2
- Pages
- 226-234
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2006749861
- Cited by
- 93
- References
- 1
- FWCI
- 3.15
- Type
- journal article
- Language
- en
- Open access
- closed
- Funders
- US Armys Telemedicine and Advanced Technology Research Center
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.