Improving the Performance Against Force Variation of EMG Controlled Multifunctional Upper-Limb Prostheses for Transradial Amputees
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
We investigate the problem of achieving robust control of hand prostheses by the electromyogram (EMG) of transradial amputees in the presence of variable force levels, as these variations can have a substantial impact on the robustness of the control of the prostheses. We also propose a novel set of features that aim at reducing the impact of force level variations on the prosthesis controlled by amputees. These features characterize the EMG activity by means of the orientation between a set of spectral moments descriptors extracted from the EMG signal and a nonlinearly mapped version of it. At the same time, our feature extraction method processes the EMG signals directly from the time-domain to reduce computational cost. The performance of the proposed features is tested on EMG data collected from nine transradial amputees performing six classes of movements each with three force levels. Our results indicate that the proposed features can achieve significant reductions in classification error rates in comparison to other well-known feature extraction methods, achieving improvements of ≈ 6% to 8% in the average classification performance across all subjects and force levels, when training with all forces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
Estimating the Prevalence of Limb Loss in the United States: 2005 to 2050
Ziegler-Graham, K., MacKenzie, E. J., Ephraim, P. L., Travison, T. G., & Brookmeyer, R. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.11.005 · Cited by 2,816
EEG analysis based on time domain properties
Hjorth, B. (1970) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(70)90143-4 · Cited by 1,504
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244 · cited 6×
“The utilized ANOVA test results indicated significant differences with p 0.001for TD-PSD vs. VD-MOM, p 0.001 for TD-PSD vs. AR+RMS, p 0.001 for TD-PSD vs. TD, and p 0.001for TD-PSD vs. Wavelet features (all results were corrected with Bonferroni analysis).”
InfluentialFarina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Scheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Mechanical design and performance specifications of anthropomorphic prosthetic hands: A review
Belter, J. T., Segil, J. L., Dollar, A. M., & Weir, R. F. (2013) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.10.0188 · Cited by 716
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606 · cited 1×
“The waveform length feature was shown to be very relevant for EMG classification tasks [38].”
BackgroundThe cepstrum: A guide to processing
Childers, D. G., Skinner, D. P., & Kemerait, R. C. (1977) · Proceedings of the IEEE · doi:10.1109/proc.1977.10747 · Cited by 600
Study of stability of time-domain features for electromyographic pattern recognition
Tkach, D., Huang, H., & Kuiken, T. A. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-21 · Cited by 582
Cited by
Surface EMG-Based Inter-Session Gesture Recognition Enhanced by Deep Domain Adaptation
Du, Y., Jin, W., Wei, W., Hu, Y., & Geng, W. (2017) · Sensors · doi:10.3390/s17030458 · Cited by 363
Feature Extraction and Selection for Myoelectric Control Based on Wearable EMG Sensors
Phinyomark, A., N. Khushaba, R., & Scheme, E. (2018) · Sensors · doi:10.3390/s18051615 · Cited by 352
Parajuli, N., Sreenivasan, N., Bifulco, P., Cesarelli, M., Savino, S., Niola, V., Esposito, D., Hamilton, T. J., Naik, G. R., Gunawardana, U., et al. (2019) · Sensors · doi:10.3390/s19204596 · Cited by 332
EMG Pattern Recognition in the Era of Big Data and Deep Learning
Phinyomark, A., & Scheme, E. (2018) · Big Data and Cognitive Computing · doi:10.3390/bdcc2030021 · Cited by 272
“[84] b Amputation, Contraction intensity (3 levels), EMG armband 9A (7M 2F) 6 5–11 1077 8–12 8 2000 16”
A review of the key technologies for sEMG-based human-robot interaction systems
Li, K., Zhang, J., Wang, L., Zhang, M., Li, J., & Bao, S. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102074 · Cited by 233
Combined influence of forearm orientation and muscular contraction on EMG pattern recognition
Khushaba, R. N., Al-Timemy, A., Kodagoda, S., & Nazarpour, K. (2016) · Expert Systems with Applications · doi:10.1016/j.eswa.2016.05.031 · Cited by 196
Self-citationSamuel, O. W., Asogbon, M. G., Geng, Y., Al-Timemy, A. H., Pirbhulal, S., Ji, N., Chen, S., Fang, P., & Li, G. (2019) · IEEE Access · doi:10.1109/access.2019.2891350 · Cited by 185
“[30] was applied to minimize the degradation in classification caused by variation in muscle contraction force level and a reduction in CE in the range of 6% to 8% was achieved.”
BackgroundMethodSelf-citationTransfer learning for sEMG hand gestures recognition using convolutional neural networks
Cote-Allard, U., Fall, C. L., Campeau-Lecours, A., Gosselin, C., Laviolette, F., & Gosselin, B. (2017) · 2017 IEEE International Conference on Systems, Man, and Cybernetics (SMC) · doi:10.1109/smc.2017.8122854 · Cited by 175
“As suggested in [16], [17], to account for the natural variability of each gesture within the same subject (i.”
BackgroundExploration of Force Myography and surface Electromyography in hand gesture classification
Jiang, X., Merhi, L.-K., Xiao, Z. G., & Menon, C. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2017.01.015 · Cited by 172
Karnam, N. K., Dubey, S. R., Turlapaty, A. C., & Gokaraju, B. (2022) · Biocybernetics and Biomedical Engineering · doi:10.1016/j.bbe.2022.02.005 · Cited by 172
“In Altimemy et al. [18], a classification of 15 hand movements for persons with intact-limbs and 12 hand movements for am-putees is performed with the Linear Discriminant Analysis (LDA) and the SVM based on the Auto Regressive (AR) features.”
MethodVidovic, M. M.-C., Hwang, H.-J., Amsuss, S., Hahne, J. M., Farina, D., & Muller, K.-R. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2492619 · Cited by 171
“It has been recently shown [16] that training and testing at different force levels is detrimental to classification performance, however proportional control is essential for good prosthesis handling.”
BackgroundEvaluating EMG feature and classifier selection for application to partial-hand prosthesis control
Adewuyi, A. A., Hargrove, L. J., & Kuiken, T. A. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00015 · Cited by 85
“…motion and are minimally sensitive to factors that degrade performance by altering the EMG signals – such as electrode shift (Young et al., 2012), muscle fatigue, muscle contraction effort (Tkach et al., 2010), force variation (Al-Timemy et al., 2015), and limb position (Al-Angari et al., 2016).”
BackgroundFukuhara, S., & Oka, H. (2019) · Advanced Biomedical Engineering · doi:10.14326/abe.8.185 · Cited by 10
Metadata
- Authors
- Al-Timemy, A. H., Khushaba, R. N., Bugmann, G., & Escudero, J.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2016-06
- Volume
- 24
- Issue
- 6
- Pages
- 650-661
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2243789297
- Cited by
- 336
- References
- 40
- FWCI
- 9.12
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.