Improving the Performance Against Force Variation of EMG Controlled Multifunctional Upper-Limb Prostheses for Transradial Amputees
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
We investigate the problem of achieving robust control of hand prostheses by the electromyogram (EMG) of transradial amputees in the presence of variable force levels, as these variations can have a substantial impact on the robustness of the control of the prostheses. We also propose a novel set of features that aim at reducing the impact of force level variations on the prosthesis controlled by amputees. These features characterize the EMG activity by means of the orientation between a set of spectral moments descriptors extracted from the EMG signal and a nonlinearly mapped version of it. At the same time, our feature extraction method processes the EMG signals directly from the time-domain to reduce computational cost. The performance of the proposed features is tested on EMG data collected from nine transradial amputees performing six classes of movements each with three force levels. Our results indicate that the proposed features can achieve significant reductions in classification error rates in comparison to other well-known feature extraction methods, achieving improvements of ≈ 6% to 8% in the average classification performance across all subjects and force levels, when training with all forces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
Estimating the Prevalence of Limb Loss in the United States: 2005 to 2050
Ziegler-Graham, K., MacKenzie, E. J., Ephraim, P. L., Travison, T. G., & Brookmeyer, R. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.11.005 · Cited by 2,816
EEG analysis based on time domain properties
Hjorth, B. (1970) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(70)90143-4 · Cited by 1,504
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244 · cited 6×
“The utilized ANOVA test results indicated significant differences with p 0.001for TD-PSD vs. VD-MOM, p 0.001 for TD-PSD vs. AR+RMS, p 0.001 for TD-PSD vs. TD, and p 0.001for TD-PSD vs. Wavelet features (all results were corrected with Bonferroni analysis).”
InfluentialFarina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Scheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Mechanical design and performance specifications of anthropomorphic prosthetic hands: A review
Belter, J. T., Segil, J. L., Dollar, A. M., & Weir, R. F. (2013) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.10.0188 · Cited by 716
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606 · cited 1×
“The waveform length feature was shown to be very relevant for EMG classification tasks [38].”
BackgroundThe cepstrum: A guide to processing
Childers, D. G., Skinner, D. P., & Kemerait, R. C. (1977) · Proceedings of the IEEE · doi:10.1109/proc.1977.10747 · Cited by 600
Study of stability of time-domain features for electromyographic pattern recognition
Tkach, D., Huang, H., & Kuiken, T. A. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-21 · Cited by 582
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 570
SRDA: An Efficient Algorithm for Large-Scale Discriminant Analysis
Cai, D., He, X., & Han, J. (2007) · IEEE Transactions on Knowledge and Data Engineering · doi:10.1109/tkde.2007.190669 · Cited by 451
The optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438
Ambulatory and inpatient procedures in the United States, 1994.
Pokras, R., Kozak, L. J., & McCarthy, E. (1997) · PubMed · Cited by 436
Myoelectric Control of Artificial Limbs—Is There a Need to Change Focus? [In the Spotlight]
Jiang, N., Dosen, S., Muller, K.-R., & Farina, D. (2012) · IEEE Signal Processing Magazine · doi:10.1109/msp.2012.2203480 · Cited by 434
Resolving the Limb Position Effect in Myoelectric Pattern Recognition
Fougner, A., Scheme, E., Chan, A. D. C., Englehart, K., & Stavdahl, Ø. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2163529 · Cited by 402
Al-Timemy, A. H., Bugmann, G., Escudero, J., & Outram, N. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2249590 · Cited by 326
Self-citationYoung, A. J., Hargrove, L. J., & Kuiken, T. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2159216 · Cited by 287
The SmartHand transradial prosthesis
Cipriani, C., Controzzi, M., & Carrozza, M. C. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-29 · Cited by 286
Jiang, N., Rehbaum, H., Vujaklija, I., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2278411 · Cited by 269 · cited 1×
“In addition, advanced control techniques such as pattern recognition (PR) based EMG control [13], [14] and regression techniques [14], [15] were also proposed and investigated.”
MethodProsthetic Myoelectric Control Strategies: A Clinical Perspective
Roche, A. D., Rehbaum, H., Farina, D., & Aszmann, O. C. (2014) · Current Surgery Reports · doi:10.1007/s40137-013-0044-8 · Cited by 261
Results of an internet survey of myoelectric prosthetic hand users
Pylatiuk, C., Schulz, S., & Döderlein, L. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640601061265 · Cited by 257 · cited 1×
“hand and finger movements were not investigated, which are the main movements needed by the transradial amputees for prosthesis control [27].”
BackgroundYoung, A. J., Hargrove, L. J., & Kuiken, T. A. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2177662 · Cited by 251
Khushaba, R. N., Takruri, M., Miro, J. V., & Kodagoda, S. (2014) · Neural Networks · doi:10.1016/j.neunet.2014.03.010 · Cited by 204
Self-citationEffect of elbow joint angle on force–EMG relationships in human elbow flexor and extensor muscles
Doheny, E. P., Lowery, M. M., FitzPatrick, D. P., & O’Malley, M. J. (2008) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2007.03.006 · Cited by 185
Geng, Y., Zhou, P., & Li, G. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-74 · Cited by 183
Development of a lightweight and adaptable multiple-axis hand prosthesis
Light, C. M., & Chappell, P. H. (2000) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00017-0 · Cited by 178
Lorrain, T., Jiang, N., & Farina, D. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-25 · Cited by 165
Daley, H., Englehart, K. B., Hargrove, L. J., & Kuruganti, U. (2012) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2011.12.012 · Cited by 143
He, J., Zhang, D., Sheng, X., Li, S., & Zhu, X. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2330356 · Cited by 134
Effect of arm position on the prediction of kinematics from EMG in amputees
Jiang, N., Muceli, S., Graimann, B., & Farina, D. (2012) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-0979-4 · Cited by 126
Correlation Analysis of Electromyogram Signals for Multiuser Myoelectric Interfaces
Khushaba, R. N. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2304470 · Cited by 122
Self-citationA note on the probability distribution function of the surface electromyogram signal
Nazarpour, K., Al-Timemy, A. H., Bugmann, G., & Andrew, J. O. (2012) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2012.09.012 · Cited by 112
Self-citationOn desensitizing the Mel-Cepstrum to spurious spectral components for Robust Speech Recognition
Tyagi, V., & Wellekens, C. J. (2006) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2005.1415167 · Cited by 79
Long term stability of surface EMG pattern classification for prosthetic control
Amsüss, S., Paredes, L. P., Rudigkeit, N., Graimann, B., Herrmann, J. M., & Farina, D. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610327 · Cited by 68
Determining delay created by multifunctional prosthesis controllers
Farrell, T. R. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.03.0055 · Cited by 39
An Overview Of The UNB Hand System
Losier, Y. G., Clawson, A. J., Wilson, A. W., Scheme, E., Englehart, K. B., Kyberd, P., & Hudgins, B. S. (2011) · DukeSpace (Duke University) · Cited by 37
Kumar, D., Arjunan, S. P., & Singh, V. P. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-50 · Cited by 35
Time-dependent spectral features for limb position invariant myoelectric pattern recognition
Khushaba, R. N., Shi, L., & Kodagoda, S. (2012) · International Symposium on Communications and Information Technologies · doi:10.1109/iscit.2012.6380840 · Cited by 29
Self-citationKryger, M., Schultz, A. E., & Kuiken, T. (2011) · Prosthetics and Orthotics International · doi:10.1177/0309364611420905 · Cited by 25
Cited by
Surface EMG-Based Inter-Session Gesture Recognition Enhanced by Deep Domain Adaptation
Du, Y., Jin, W., Wei, W., Hu, Y., & Geng, W. (2017) · Sensors · doi:10.3390/s17030458 · Cited by 363
Feature Extraction and Selection for Myoelectric Control Based on Wearable EMG Sensors
Phinyomark, A., N. Khushaba, R., & Scheme, E. (2018) · Sensors · doi:10.3390/s18051615 · Cited by 352
Parajuli, N., Sreenivasan, N., Bifulco, P., Cesarelli, M., Savino, S., Niola, V., Esposito, D., Hamilton, T. J., Naik, G. R., Gunawardana, U., et al. (2019) · Sensors · doi:10.3390/s19204596 · Cited by 332
EMG Pattern Recognition in the Era of Big Data and Deep Learning
Phinyomark, A., & Scheme, E. (2018) · Big Data and Cognitive Computing · doi:10.3390/bdcc2030021 · Cited by 272
“[84] b Amputation, Contraction intensity (3 levels), EMG armband 9A (7M 2F) 6 5–11 1077 8–12 8 2000 16”
A review of the key technologies for sEMG-based human-robot interaction systems
Li, K., Zhang, J., Wang, L., Zhang, M., Li, J., & Bao, S. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102074 · Cited by 233
Metadata
- Authors
- Al-Timemy, A. H., Khushaba, R. N., Bugmann, G., & Escudero, J.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2016-06
- Volume
- 24
- Issue
- 6
- Pages
- 650-661
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2243789297
- Cited by
- 336
- References
- 40
- FWCI
- 9.12
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.