Context-Dependent Upper Limb Prosthesis Control for Natural and Robust Use
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Pattern recognition and regression methods applied to the surface EMG have been used for estimating the user intended motor tasks across multiple degrees of freedom (DOF), for prosthetic control. While these methods are effective in several conditions, they are still characterized by some shortcomings. In this study we propose a methodology that combines these two approaches for mutually alleviating their limitations. This resulted in a control method capable of context-dependent movement estimation that switched automatically between sequential (one DOF at a time) or simultaneous (multiple DOF) prosthesis control, based on an online estimation of signal dimensionality. The proposed method was evaluated in scenarios close to real-life situations, with the control of a physical prosthesis in applied tasks of varying difficulties. Test prostheses were individually manufactured for both able-bodied and transradial amputee subjects. With these prostheses, two amputees performed the Southampton Hand Assessment Procedure test with scores of 58 and 71 points. The five able-bodied individuals performed standardized tests, such as the box&block and clothes pin test, reducing the completion times by up to 30%, with respect to using a state-of-the-art pure sequential control algorithm. Apart from facilitating fast simultaneous movements, the proposed control scheme was also more intuitive to use, since human movements are predominated by simultaneous activations across joints. The proposed method thus represents a significant step towards intelligent, intuitive and natural control of upper limb prostheses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 2×
“Here, the main processing took place, including extraction of root mean square (rms), zero crossings, slope sign change and waveform length features [20] as well as the estimation of all eight motions as described above.”
BackgroundMethodKuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583
Light, C. M., Chappell, P. H., & Kyberd, P. J. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2002.32737 · Cited by 417 · cited 2×
“For all tests and the exact test procedure, the reader is referred to [36] and in summary to Tables II and III.”
MethodOrtiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-33 · Cited by 144 · cited 1×
“In order to overcome this issue, direct control of multiple DOF through intra-muscular EMG recording [9], [10] has been proposed.”
Background
Research works printed but not linked: 41
- 0, Patterson Medical
- 10.5014/ajot.39.6.386 · DOI · Paper page
- holm, 1979, A simple sequentially rejective Bonferroni test procedure, Scand J Stat, 6, 65
- 10.1109/TBME.2013.2238939 · DOI · Paper page
- amsuess, 0, A novel multi-class proportional myocontrol algorithm for upper limb prosthesis control: Validation in real-life scenarios on amputees, IEEE Trans Neural Syst Rehabil Eng
- theodoridis, 2008, Pattern Recognition
- cromwell, 1960, Occupational therapist's manual for basic skills assessment or primary pre-vocational evaluation
- 10.1109/NER.2013.6695946 · doi:10.1109/ner.2013.6695946
- 10.1109/TNSRE.2014.2361478 · DOI
- smith, 2014, Simultaneous control of a multi-DOF wrist hand system using parallel dual site control with intramuscular EMG, Proc 2014 MyoElectric Controls Symp, 240
- 10.1109/EMBC.2012.6346886 · DOI
- 10.1186/1743-0003-11-5 · DOI · Paper page
- 10.1109/TBME.2003.820998 · DOI · Paper page
- 10.1109/TBME.2008.2007967 · DOI · Paper page
- 10.1109/TNSRE.2014.2305520 · DOI · Paper page
- 10.1109/TNSRE.2014.2323576 · DOI · Paper page
- 10.1109/IEMBS.2007.4353749 · DOI
- jiang, 2008, Extracting force functions from the multi-channel surface electromyographic signal
- 10.1109/TNSRE.2013.2287383 · DOI · Paper page
- bodesheim, 2013, KNFST MATLAB Code
- 10.3109/17483107.2011.635405 · DOI · Paper page
- ye, 2006, Computational and theoretical analysis of null space and orthogonal linear discriminant analysis, J Mach Learn Res, 7, 1183
- 10.1097/PHM.0b013e3181587f6c · DOI · Paper page
- finley, 1967, Myocoder-computer study of electromyographic patterns, Arch Phys Med Rehabil, 48, 20
- fukunaga, 1990, Introduction to statistical pattern recognition
- 10.1097/00008526-199600810-00003 · DOI · Paper page
- 10.1682/JRRD.2010.08.0161 · DOI · Paper page
- herberts, 1978, Clinical application study of multifunctional prosthetic hands, J Bone Joint Surg, 60 b, 552, 10.1302/0301-620X.60B4.711808 · DOI
- 10.1016/j.jphysparis.2009.07.009 · DOI
- chiovetto, 2014, Assessment of human-likeness and naturalness of interceptive arm reaching movement accomplished by a humanoid robot, ECVP2014
- 10.1186/1743-0003-11-75 · DOI
- castellini, 2014, EMG based prediction of multi-DOF activations using single-DOF training a preliminary resulto title, Proc 2014 MyoElectric Controls Symp, 45
- amsuess, 2012, Applying LDA to accomplish simultaneous 2-DOF movements using visual feedback, Proc Annu Int IEEE-EMBS Conf
- 10.1186/1743-0003-11-72 · DOI
- 10.1016/j.sigpro.2003.07.019 · DOI · Paper page
- 10.1682/JRRD.2011.09.0179 · DOI
- schoelkopf, 1999, Support vector method for novelty detection, NIPS, 12, 582
- stein, 1983, Functional comparison of upper extremity amputees using myoelectric and conventional prostheses, Arch Phys Med Rehabil, 64, 243
- 10.1109/CVPR.2013.433 · DOI · Paper page
- atkins, 2013, A Functional Baseline Index Standard for Electric Multi-Articulating Hands And Digits
- chih-chung, 0, Lib-SVM
Cited by
Farina, D., Vujaklija, I., Sartori, M., Kapelner, T., Negro, F., Jiang, N., Bergmeister, K., Andalib, A., Principe, J., & Aszmann, O. C. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0025 · Cited by 359
“= = = = arg d d R LR LR max 1 ( ) 1 ( ) (7) R j n”
Self-citationToward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citationSartori, M., Durandau, G., Došen, S., & Farina, D. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae26b · Cited by 148
“first was a block-turn task [43] involving a sequence of fine control actions including: grasping a narrow 384 wooden block placed on a high self, rotating it of 90 degrees, placing it back on the shelf, re-grasping the 385 block, rotating it back of 90 degrees, and replacing the block back to its initial position.”
BackgroundSelf-citationPeripheral nerve bionic interface: a review of electrodes
Russell, C., Roche, A. D., & Chakrabarty, S. (2019) · International Journal of Intelligent Robotics and Applications · doi:10.1007/s41315-019-00086-3 · Cited by 67
Self-citation
Metadata
- Authors
- Amsuess, S., Vujaklija, I., Goebel, P., Roche, A. D., Graimann, B., Aszmann, O. C., & Farina, D.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2016-07
- Volume
- 24
- Issue
- 7
- Pages
- 744-753
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W882418563
- Cited by
- 109
- References
- 4
- FWCI
- 4.40
- Type
- journal article
- Language
- en
- Open access
- green
- Funders
- Research Executive Agency (251555)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Context-Dependent Upper Limb Prosthesis Control for Natural and Robust Use. https://app.cochat.ai/papers/10.1109/tnsre.2015.2454240
- The paper
- Amsuess, S., Vujaklija, I., Goebel, P., Roche, A. D., Graimann, B., Aszmann, O. C., & Farina, D. (2016). Context-Dependent Upper Limb Prosthesis Control for Natural and Robust Use. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2015.2454240
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.