CoChat

Effects of Different Tactile Feedback on Myoelectric Closed-Loop Control for Grasping Based on Electrotactile Stimulation

Xu, Heng, Zhang, Dingguo, Huegel, Joel C., Xu, Wendong, Zhu, Xiangyang · 2016 · IEEE Transactions on Neural Systems and Rehabilitation Engineering
Cited by 44

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Closed-loop control is important for amputees to manipulate myoelectric prostheses intuitively and dexterously. Tactile feedback can help amputees improve myoelectric control performance for grasping objects. To investigate the effects of different tactile feedback, we performed experiments on six amputees and six able-bodied subjects via electrotactile stimulation. Using a virtual environment, six kinds of objects with different weights and stiffnesses were used for grasping tasks. Five feedback conditions (no feedback, pressure feedback, slip feedback, pressure + slip feedback, and vision feedback) were considered. Nine evaluation indexes and three control objectives (rapidity, economy, and stability) were proposed. Under the five feedback conditions, our study investigated four issues: 1) three types of grasping-related failures; 2) four types of grasping-related time measures; 3) average grasping force; 4) standard deviation of the grasping force. Results indicate that: 1) slip feedback is better than pressure feedback; 2) pressure + slip feedback can improve grasping rapidity; 3) slip feedback significantly contributes to grasping economy and stability; and 4) pressure + slip feedback can perform as well as vision feedback.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2015.2478153

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 44

Metadata

Authors
Xu, H., Zhang, D., Huegel, J. C., Xu, W., & Zhu, X.
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2016-08
Volume
24
Issue
8
Pages
827-836
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2403612607
Cited by
44
References
5
FWCI
1.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of Different Tactile Feedback on Myoelectric Closed-Loop Control for Grasping Based on Electrotactile Stimulation. https://app.cochat.ai/papers/10.1109/tnsre.2015.2478153
The paper
Xu, H., Zhang, D., Huegel, J. C., Xu, W., & Zhu, X. (2016). Effects of Different Tactile Feedback on Myoelectric Closed-Loop Control for Grasping Based on Electrotactile Stimulation. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2015.2478153

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.