Closed-Loop Continuous Hand Control via Chronic Recording of Regenerative Peripheral Nerve Interfaces
The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
Loss of the upper limb imposes a devastating interruption to everyday life. Full restoration of natural arm control requires the ability to simultaneously control multiple degrees of freedom of the prosthetic arm and maintain that control over an extended period of time. Current clinically available myoelectric prostheses do not provide simultaneous control or consistency for transradial amputees. To address this issue, we have implemented a standard Kalman filter for continuous hand control using intramuscular electromyography (EMG) from both regenerative peripheral nerve interfaces (RPNI) and an intact muscle within non-human primates. Seven RPNIs and one intact muscle were implanted with indwelling bipolar intramuscular electrodes in two rhesus macaques. Following recuperations, function-specific EMG signals were recorded and then fed through the Kalman filter during a hand-movement behavioral task to continuously predict the monkey's finger position. We were able to reconstruct continuous finger movement offline with an average correlation of and a root mean squared error (RMSE) of 0.12 between actual and predicted position from two macaques. This finger movement prediction was also performed in real time to enable closed-loop neural control of a virtual hand. Compared with physical hand control, neural control performance was slightly slower but maintained an average target hit success rate of 96.70%. Recalibration longevity measurements maintained consistent average correlation over time but had a significant change in RMSE ( ). Additionally, extracted single units varied in amplitude by a factor of +18.65% and -25.85% compared with its mean. This is the first demonstration of chronic indwelling electrodes being used for continuous position control via the Kalman filter. Combining these analyses with our novel peripheral nerve interface, we believe that this demonstrates an important step in providing patients with more naturalistic control of their prosthetic limbs.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This process creates a stable, peripheral nerve bioamplifier that produces high-amplitude EMG signals, which could be used to control a prosthetic device (14–17).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [14]
In the citing paper
“In another animal study, RPNIs were combined with intramuscular electrodes and demonstrated the chronic recording capability of this method for up to twenty months [43].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [43]
Citations
Cites
A New Approach to Linear Filtering and Prediction Problems
Kalman, R. E. (1960) · Journal of Basic Engineering · doi:10.1115/1.3662552 · Cited by 31,751 · cited 1×
“The Kalman filter is a recursive linear filter that tracks the state of a dynamical system throughout time using noisy measurements [27], [28], [30] relying on a trajectory model and an observation model.”
BackgroundEstimating the Prevalence of Limb Loss in the United States: 2005 to 2050
Ziegler-Graham, K., MacKenzie, E. J., Ephraim, P. L., Travison, T. G., & Brookmeyer, R. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.11.005 · Cited by 2,816
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 1×
“We extracted two temporal characteristic features of the EMG waveform: (1) mean absolute value (MAV) and (2) waveform line length (LL) [31], [32].”
MethodCombinations of muscle synergies in the construction of a natural motor behavior
d'Avella, A., Saltiel, P., & Bizzi, E. (2003) · Nature Neuroscience · doi:10.1038/nn1010 · Cited by 1,344
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089 · cited 1×
“jects [8], [10], [11], [12].”
Soukoreff, R. W., & MacKenzie, I. S. (2004) · International Journal of Human-Computer Studies · doi:10.1016/j.ijhcs.2004.09.001 · Cited by 1,064
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Limb Amputation and Limb Deficiency: Epidemiology and Recent Trends in the United States
DILLINGHAM, T. R., PEZZIN, L. E., & MACKENZIE, E. J. (2002) · Southern Medical Journal · doi:10.1097/00007611-200208000-00018 · Cited by 822
A wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697 · cited 2×
“pronation/supination, and radial/ulnar deviation [4], [5], [6] with further studies using EMG feature patterns to control”
BackgroundOrtiz-Catalan, M., Håkansson, B., & Brånemark, R. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008933 · Cited by 484 · cited 1×
“The higher SNR reported here and by others [37], [43], motivates additional development in multi-channel intramus-”
BackgroundBayesian Population Decoding of Motor Cortical Activity Using a Kalman Filter
Wu, W., Gao, Y., Bienenstock, E., Donoghue, J. P., & Black, M. J. (2006) · Neural Computation · doi:10.1162/089976606774841585 · Cited by 456
A heuristic fuzzy logic approach to EMG pattern recognition for multifunctional prosthesis control
Ajiboye, A. B., & Weir, R. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847357 · Cited by 415 · cited 1×
“jects [8], [10], [11], [12].”
Kim, S.-P., Simeral, J. D., Hochberg, L. R., Donoghue, J. P., & Black, M. J. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/4/010 · Cited by 397
Double nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396 · cited 4×
“8 but greater than the SNRs reported for intrafascicular electrodes [19], [22].”
BackgroundInfluentialLinear and Nonlinear Regression Techniques for Simultaneous and Proportional Myoelectric Control
Hahne, J. M., Biebmann, F., Jiang, N., Rehbaum, H., Farina, D., Meinecke, F. C., Muller, K.-R., & Parra, L. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305520 · Cited by 365
Dhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354
Chu, J.-U., Moon, I., & Mun, M.-S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883695 · Cited by 352
Chestek, C. A., Gilja, V., Nuyujukian, P., Foster, J. D., Fan, J. M., Kaufman, M. T., Churchland, M. M., Rivera-Alvidrez, Z., Cunningham, J. P., Ryu, S. I., et al. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/045005 · Cited by 350
Self-citationDecoding of Individuated Finger Movements Using Surface Electromyography
Tenore, F. V. G., Ramos, A., Fahmy, A., Acharya, S., Etienne-Cummings, R., & Thakor, N. V. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005485 · Cited by 342
Toward improved control of prosthetic fingers using surface electromyogram (EMG) signals
Khushaba, R. N., Kodagoda, S., Takruri, M., & Dissanayake, G. (2012) · Expert Systems with Applications · doi:10.1016/j.eswa.2012.02.192 · Cited by 323
Davis, T. S., Wark, H. A. C., Hutchinson, D. T., Warren, D. J., O’Neill, K., Scheinblum, T., Clark, G. A., Normann, R. A., & Greger, B. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036001 · Cited by 314
Young, A. J., Hargrove, L. J., & Kuiken, T. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2159216 · Cited by 287
Muceli, S., & Farina, D. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2178039 · Cited by 285
Jiang, N., Rehbaum, H., Vujaklija, I., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2278411 · Cited by 269 · cited 1×
“Previous continuous decoding studies have either used percutaneous fine-wire electrodes or surface electrodes to obtain EMG signals [13], [14], [35], [38] with few decoding isolated finger movements [16], [39].”
BackgroundImplantable Myoelectric Sensors (IMESs) for Intramuscular Electromyogram Recording
Weir, R. F., Troyk, P. R., DeMichele, G. A., Kerns, D. A., Schorsch, J. F., & Maas, H. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005942 · Cited by 266
Peripheral nerve fascicles: Anatomy and clinical relevance
Stewart, J. D. (2003) · Muscle & Nerve · doi:10.1002/mus.10454 · Cited by 265
Prosthetic Myoelectric Control Strategies: A Clinical Perspective
Roche, A. D., Rehbaum, H., Farina, D., & Aszmann, O. C. (2014) · Current Surgery Reports · doi:10.1007/s40137-013-0044-8 · Cited by 261
EMG Pattern Analysis and Classification for a Prosthetic Arm
Saridis, G. N., & Gootee, T. P. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324954 · Cited by 236
Online Myoelectric Control of a Dexterous Hand Prosthesis by Transradial Amputees
Cipriani, C., Antfolk, C., Controzzi, M., Lundborg, G., Rosen, B., Carrozza, M. C., & Sebelius, F. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2108667 · Cited by 233 · cited 1×
“jects [8], [10], [11], [12].”
Real-Time Myoprocessors for a Neural Controlled Powered Exoskeleton Arm
Cavallaro, E. E., Rosen, J., Perry, J. C., & Burns, S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.880883 · Cited by 230
Decoding a New Neural–Machine Interface for Control of Artificial Limbs
Zhou, P., Lowery, M. M., Englehart, K. B., Huang, H., Li, G., Hargrove, L., Dewald, J. P. A., & Kuiken, T. A. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00178.2007 · Cited by 215 · cited 1×
“We extracted two temporal characteristic features of the EMG waveform: (1) mean absolute value (MAV) and (2) waveform line length (LL) [31], [32].”
MethodSchieber, M. H. (1991) · Journal of Neurophysiology · doi:10.1152/jn.1991.65.6.1381 · Cited by 215
Pasquina, P. F., Evangelista, M., Carvalho, A. J., Lockhart, J., Griffin, S., Nanos, G., McKay, P., Hansen, M., Ipsen, D., Vandersea, J., et al. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.07.016 · Cited by 205
Ngeo, J. G., Tamei, T., & Shibata, T. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-122 · Cited by 198
Kung, T. A., Langhals, N. B., Martin, D. C., Johnson, P. J., Cederna, P. S., & Urbanchek, M. G. (2014) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000000168 · Cited by 181 · cited 2×
“The RPNIs can generate recordable high-amplitude EMG activity, acting as bioamplifiers for efferent peripheral nerve signals [23], [24].”
BackgroundSelf-citationCunningham, J. P., Nuyujukian, P., Gilja, V., Chestek, C. A., Ryu, S. I., & Shenoy, K. V. (2011) · Journal of Neurophysiology · doi:10.1152/jn.00503.2010 · Cited by 176
Self-citationSupport Vector Regression for Improved Real-Time, Simultaneous Myoelectric Control
Ameri, A., Kamavuako, E. N., Scheme, E. J., Englehart, K. B., & Parker, P. A. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2323576 · Cited by 171
Adaptive Decoding for Brain-Machine Interfaces Through Bayesian Parameter Updates
Li, Z., O'Doherty, J. E., Lebedev, M. A., & Nicolelis, M. A. L. (2011) · Neural Computation · doi:10.1162/neco_a_00207 · Cited by 128
Axon diameters and conduction velocities in the macaque pyramidal tract
Firmin, L., Field, P. M., Maier, M. A., Kraskov, A., Kirkwood, P., Nakajima, K., Lemon, R., & Glickstein, M. (2014) · Journal of Neurophysiology · doi:10.1152/jn.00720.2013 · Cited by 121
Muceli, S., Poppendieck, W., Negro, F., Yoshida, K., Hoffmann, K. P., Butler, J. E., Gandevia, S. C., & Farina, D. (2015) · The Journal of Physiology · doi:10.1113/jp270902 · Cited by 116
Evaluation of Linear Regression Simultaneous Myoelectric Control Using Intramuscular EMG
Smith, L. H., Kuiken, T. A., & Hargrove, L. J. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2469741 · Cited by 112
Neural Networks for Online Classification of Hand and Finger Movements Using Surface EMG signals
Tsenov, G., Zeghbib, A. H., Palis, F., Shoylev, N., & Mladenov, V. (2006) · 2006 8th Seminar on Neural Network Applications in Electrical Engineering · doi:10.1109/neurel.2006.341203 · Cited by 105
Micera, S., Citi, L., Rigosa, J., Carpaneto, J., Raspopovic, S., Di Pino, G., Rossini, L., Yoshida, K., Denaro, L., Dario, P., et al. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2038726 · Cited by 101
A Virtual Reality Environment for Designing and Fitting Neural Prosthetic Limbs
Hauschild, M., Davoodi, R., & Loeb, G. E. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891369 · Cited by 97
Performance measurement for brain–computer or brain–machine interfaces: a tutorial
Thompson, D. E., Quitadamo, L. R., Mainardi, L., Laghari, K. U. R., Gao, S., Kindermans, P.-J., Simeral, J. D., Fazel-Rezai, R., Matteucci, M., Falk, T. H., et al. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/035001 · Cited by 87
Self-citationMultichannel thin-film electrode for intramuscular electromyographic recordings
Farina, D., Yoshida, K., Stieglitz, T., & Koch, K. P. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00788.2007 · Cited by 85
Irwin, Z. T., Schroeder, K. E., Vu, P. P., Tat, D. M., Bullard, A. J., Woo, S. L., Sando, I. C., Urbanchek, M. G., Cederna, P. S., & Chestek, C. A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046007 · Cited by 78 · cited 4×
“[25].”
BackgroundMethodInfluentialSelf-citationSelf-recalibrating classifiers for intracortical brain–computer interfaces
Bishop, W., Chestek, C. C., Gilja, V., Nuyujukian, P., Foster, J. D., Ryu, S. I., Shenoy, K. V., & Yu, B. M. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026001 · Cited by 60
Self-citationSimultaneous and Proportional Force Estimation in Multiple Degrees of Freedom From Intramuscular EMG
Kamavuako, E. N., Englehart, K. B., Jensen, W., & Farina, D. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2197210 · Cited by 59
In vivo characterization of regenerative peripheral nerve interface function
Ursu, D. C., Urbanchek, M. G., Nedic, A., Cederna, P. S., & Gillespie, R. B. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026012 · Cited by 46
Self-citationReal-time myoelectric decoding of individual finger movements for a virtual target task
Smith, R. J., Huberdeau, D. M., Tenore, F. V., & Thakor, N. V. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5334981 · Cited by 35
A Fully Implanted Intramuscular Bipolar Myoelectric Signal Recording Electrode
Memberg, W. D., Stage, T. G., & Kirsch, R. F. (2014) · Neuromodulation Technology at the Neural Interface · doi:10.1111/ner.12165 · Cited by 34
A Novel Motion Estimate Method of Human Joint with EMG-Driven Model
Ding, Q., Zhao, X., Xiong, A., & Han, J. (2011) · International Conference on Bioinformatics and Biomedical Engineering · doi:10.1109/icbbe.2011.5780185 · Cited by 30
A lower limb EMG-driven biomechanical model for applications in rehabilitation robotics
Sartori, M., Reggiani, M., Mezzato, C., & Pagello, E. (2009) · Padua Research Archive (University of Padova) · Cited by 18
Use of probabilistic weights to enhance linear regression myoelectric control
Smith, L. H., Kuiken, T. A., & Hargrove, L. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/6/066030 · Cited by 15 · cited 3×
“[18], [35] has used the Wiener filter as a baseline comparison to their algorithm’s performance with”
BackgroundMethodDecoding individuated finger flexions with Implantable MyoElectric Sensors
Baker, J. J., Yatsenko, D., Schorsch, J. F., DeMichele, G. A., Troyk, P. R., Hutchinson, D. T., Weir, R. F. F., Clark, G. A., & Greger, B. E. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649123 · Cited by 11
Cited by
Vu, P. P., Vaskov, A. K., Irwin, Z. T., Henning, P. T., Lueders, D. R., Laidlaw, A. T., Davis, A. J., Nu, C. S., Gates, D. H., Gillespie, R. B., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aay2857 · Cited by 291
Self-citationToward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Intuitive neuromyoelectric control of a dexterous bionic arm using a modified Kalman filter
George, J. A., Davis, T. S., Brinton, M. R., & Clark, G. A. (2019) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108462 · Cited by 118
Human motor decoding from neural signals: a review
Tam, W.-K., Wu, T., Zhao, Q., Keefer, E. W., & Yang, Z. (2019) · BMC Biomedical Engineering · doi:10.1186/s42490-019-0022-z · Cited by 120
Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review
Yildiz, K. A., Shin, A. Y., & Kaufman, K. R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00667-5 · Cited by 113
Metadata
- Authors
- Vu, P. P., Irwin, Z. T., Bullard, A. J., Ambani, S. W., Sando, I. C., Urbanchek, M. G., Cederna, P. S., & Chestek, C. A.
- Affiliations
- University of Michigan (US)
- ORCID
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2018-02
- Volume
- 26
- Issue
- 2
- Pages
- 515-526
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2770125713
- Cited by
- 61
- References
- 56
- Citations by year
- 2026: 4 · 2025: 5 · 2024: 6 · 2023: 4 · 2022: 10 · 2021: 10 · 2020: 11 · 2019: 10 · 2018: 1
- FWCI
- 2.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Wallace H. Coulter Foundation
- Plastic Surgery Foundation
- Frederick A. Coller Surgical Society
- NSF Graduate Research Fellowships
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- regenerative peripheral nerve interface, Kalman filter, intramuscular electromyography, transradial amputation, upper limb prosthesis, rhesus monkeys, single-unit activity, recalibration, non-human primates
- MeSH terms
- Algorithms, Animals, Artificial Limbs, Calibration, Electric Stimulation, Electromyography, Fingers, Macaca mulatta, Peripheral Nerves, Prosthesis Design, Psychomotor Performance, User-Computer Interface, Upper Extremity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.