Closed-Loop Continuous Hand Control via Chronic Recording of Regenerative Peripheral Nerve Interfaces
The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
Loss of the upper limb imposes a devastating interruption to everyday life. Full restoration of natural arm control requires the ability to simultaneously control multiple degrees of freedom of the prosthetic arm and maintain that control over an extended period of time. Current clinically available myoelectric prostheses do not provide simultaneous control or consistency for transradial amputees. To address this issue, we have implemented a standard Kalman filter for continuous hand control using intramuscular electromyography (EMG) from both regenerative peripheral nerve interfaces (RPNI) and an intact muscle within non-human primates. Seven RPNIs and one intact muscle were implanted with indwelling bipolar intramuscular electrodes in two rhesus macaques. Following recuperations, function-specific EMG signals were recorded and then fed through the Kalman filter during a hand-movement behavioral task to continuously predict the monkey's finger position. We were able to reconstruct continuous finger movement offline with an average correlation of and a root mean squared error (RMSE) of 0.12 between actual and predicted position from two macaques. This finger movement prediction was also performed in real time to enable closed-loop neural control of a virtual hand. Compared with physical hand control, neural control performance was slightly slower but maintained an average target hit success rate of 96.70%. Recalibration longevity measurements maintained consistent average correlation over time but had a significant change in RMSE ( ). Additionally, extracted single units varied in amplitude by a factor of +18.65% and -25.85% compared with its mean. This is the first demonstration of chronic indwelling electrodes being used for continuous position control via the Kalman filter. Combining these analyses with our novel peripheral nerve interface, we believe that this demonstrates an important step in providing patients with more naturalistic control of their prosthetic limbs.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This process creates a stable, peripheral nerve bioamplifier that produces high-amplitude EMG signals, which could be used to control a prosthetic device (14–17).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [14]
In the citing paper
“In another animal study, RPNIs were combined with intramuscular electrodes and demonstrated the chronic recording capability of this method for up to twenty months [43].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [43]
Citations
Cites
A New Approach to Linear Filtering and Prediction Problems
Kalman, R. E. (1960) · Journal of Basic Engineering · doi:10.1115/1.3662552 · Cited by 31,751 · cited 1×
“The Kalman filter is a recursive linear filter that tracks the state of a dynamical system throughout time using noisy measurements [27], [28], [30] relying on a trajectory model and an observation model.”
BackgroundEstimating the Prevalence of Limb Loss in the United States: 2005 to 2050
Ziegler-Graham, K., MacKenzie, E. J., Ephraim, P. L., Travison, T. G., & Brookmeyer, R. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.11.005 · Cited by 2,816
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 1×
“We extracted two temporal characteristic features of the EMG waveform: (1) mean absolute value (MAV) and (2) waveform line length (LL) [31], [32].”
MethodCombinations of muscle synergies in the construction of a natural motor behavior
d'Avella, A., Saltiel, P., & Bizzi, E. (2003) · Nature Neuroscience · doi:10.1038/nn1010 · Cited by 1,344
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089 · cited 1×
“jects [8], [10], [11], [12].”
Soukoreff, R. W., & MacKenzie, I. S. (2004) · International Journal of Human-Computer Studies · doi:10.1016/j.ijhcs.2004.09.001 · Cited by 1,064
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Limb Amputation and Limb Deficiency: Epidemiology and Recent Trends in the United States
DILLINGHAM, T. R., PEZZIN, L. E., & MACKENZIE, E. J. (2002) · Southern Medical Journal · doi:10.1097/00007611-200208000-00018 · Cited by 822
A wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697 · cited 2×
“pronation/supination, and radial/ulnar deviation [4], [5], [6] with further studies using EMG feature patterns to control”
BackgroundOrtiz-Catalan, M., Håkansson, B., & Brånemark, R. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008933 · Cited by 484 · cited 1×
“The higher SNR reported here and by others [37], [43], motivates additional development in multi-channel intramus-”
Background
Cited by
Vu, P. P., Vaskov, A. K., Irwin, Z. T., Henning, P. T., Lueders, D. R., Laidlaw, A. T., Davis, A. J., Nu, C. S., Gates, D. H., Gillespie, R. B., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aay2857 · Cited by 291
Self-citationToward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Intuitive neuromyoelectric control of a dexterous bionic arm using a modified Kalman filter
George, J. A., Davis, T. S., Brinton, M. R., & Clark, G. A. (2019) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108462 · Cited by 118
Human motor decoding from neural signals: a review
Tam, W.-K., Wu, T., Zhao, Q., Keefer, E. W., & Yang, Z. (2019) · BMC Biomedical Engineering · doi:10.1186/s42490-019-0022-z · Cited by 120
Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review
Yildiz, K. A., Shin, A. Y., & Kaufman, K. R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00667-5 · Cited by 113
When Bio Meets Technology: Biohybrid Neural Interfaces
Rochford, A. E., Carnicer‐Lombarte, A., Curto, V. F., Malliaras, G. G., & Barone, D. G. (2019) · Advanced Materials · doi:10.1002/adma.201903182 · Cited by 111
Regenerative Peripheral Nerve Interfaces for Prevention and Management of Neuromas
Santosa, K. B., Oliver, J. D., Cederna, P. S., & Kung, T. A. (2020) · Clinics in Plastic Surgery · doi:10.1016/j.cps.2020.01.004 · Cited by 97
Self-citationVu, P. P., Vaskov, A. K., Lee, C., Jillala, R., Wallace, D. M., Davis, A. J., Kung, T. A., Kemp, S. W. P., Gates, D. H., Chestek, C. A., et al. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/accb0c · Cited by 66
Self-citationArtificial Intelligence Enables Real-Time and Intuitive Control of Prostheses via Nerve Interface
Luu, D. K., Nguyen, A. T., Jiang, M. X., Drealan, M. W., Xu, J., Wu, T., Tam, W.-K., Zhao, W., Lim, B. Z. H., Overstreet, C. K., et al. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2022.3160618 · Cited by 65
“Decreasing Postamputation Pain with the Regenerative Peripheral Nerve Interface (RPNI)”
Kubiak, C. A., Adidharma, W., Kung, T. A., Kemp, S. W. P., Cederna, P. S., & Vemuri, C. (2021) · Annals of Vascular Surgery · doi:10.1016/j.avsg.2021.08.014 · Cited by 58
Self-citationA bioelectric neural interface towards intuitive prosthetic control for amputees
Nguyen, A. T., Xu, J., Jiang, M., Luu, D. K., Wu, T., Tam, W.-K., Zhao, W., Drealan, M. W., Overstreet, C. K., Zhao, Q., et al. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abc3d3 · Cited by 52
A Wireless Multi-Channel Peripheral Nerve Signal Acquisition System-on-Chip
Ng, K. A., Yuan, C., Rusly, A., Do, A.-T., Zhao, B., Liu, S.-C., Peh, W. Y. X., Thow, X. Y., Voges, K., Lee, S., et al. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2909158 · Cited by 47
Selective peripheral nerve recordings from nerve cuff electrodes using convolutional neural networks
Koh, R. G. L., Balas, M., Nachman, A., & Zariffa, J. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab4ac4 · Cited by 52
Regenerative Peripheral Nerve Interface Surgery: Anatomic and Technical Guide
Leach, G. A., Dean, R. A., Kumar, N. G., Tsai, C., Chiarappa, F. E., Cederna, P. S., Kung, T. A., & Reid, C. M. (2023) · Plastic & Reconstructive Surgery Global Open · doi:10.1097/gox.0000000000005127 · Cited by 49
Self-citationVaskov, A. K., Vu, P. P., North, N., Davis, A. J., Kung, T. A., Gates, D. H., Cederna, P. S., & Chestek, C. A. (2022) · IEEE Transactions on Robotics · doi:10.1109/tro.2022.3170720 · Cited by 45
Self-citationPaskett, M. D., Brinton, M. R., Hansen, T. C., George, J. A., Davis, T. S., Duncan, C. C., & Clark, G. A. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00839-x · Cited by 43
Regenerative peripheral nerve interface free muscle graft mass and function
Hu, Y., Ursu, D. C., Sohasky, R. A., Sando, I. C., Ambani, S. W., French, Z. P., Mays, E. A., Nedic, A., Moon, J. D., Kung, T. A., et al. (2020) · Muscle & Nerve · doi:10.1002/mus.27138 · Cited by 42
Self-citationKoh, R. G. L., Nachman, A., & Zariffa, J. (2019) · Scientific Reports · doi:10.1038/s41598-019-47450-8 · Cited by 41
The future of upper extremity rehabilitation robotics: research and practice
Vu, P. P., Chestek, C. A., Nason, S. R., Kung, T. A., Kemp, S. W. P., & Cederna, P. S. (2020) · Muscle & Nerve · doi:10.1002/mus.26860 · Cited by 38
Self-citationGuo, Y., Sun, L., Zhong, W., Zhang, N., Zhao, Z., & Tian, W. (2024) · PubMed Central · doi:10.4103/1673-5374.380909 · Cited by 35
Deep Learning-Based Approaches for Decoding Motor Intent From Peripheral Nerve Signals
Luu, D. K., Nguyen, A. T., Jiang, M. X., Xu, J., Drealan, M. W., Cheng, J., Keefer, E. W., Zhao, Q., & Yang, Z. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.667907 · Cited by 31
Kubiak, C. A., Svientek, S. R., Dehdashtian, A., Lawera, N. G., Nadarajan, V., Bratley, J. V., Kung, T. A., Cederna, P. S., & Kemp, S. W. P. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac1b6b · Cited by 30
Self-citationStrategies for neural control of prosthetic limbs: from electrode interfacing to 3D printing
Ngan, C., Kapsa, R. M. I., & Choong, P. (2019) · Materials · doi:10.3390/ma12121927 · Cited by 26
Regenerative Peripheral Nerve Interfaces for Advanced Control of Upper Extremity Prosthetic Devices
Kumar, N. G., Kung, T. A., & Cederna, P. S. (2021) · Hand Clinics · doi:10.1016/j.hcl.2021.04.005 · Cited by 26
Self-citationWu, J., Zhang, Y., Zhang, X., Lin, Z., & Li, G. (2022) · Frontiers in Molecular Neuroscience · doi:10.3389/fnmol.2022.938930 · Cited by 22
Regenerative peripheral nerve interfaces (RPNIs): an overview of innovative surgical approaches
Berberoglu, I., Burke, K. L., Cederna, P. S., & Kemp, S. W. P. (2024) · Plastic and Aesthetic Research · doi:10.20517/2347-9264.2023.101 · Cited by 20
Self-citationTutorial: a guide to techniques for analysing recordings from the peripheral nervous system
Koh, R. G. L., Zariffa, J., Jabban, L., Yen, S., Donaldson, N., & Metcalfe, B. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac7d74 · Cited by 19
Experimental Testing of Bionic Peripheral Nerve and Muscle Interfaces: Animal Model Considerations
Aman, M., Bergmeister, K. D., Festin, C., Sporer, M. E., Russold, M., Gstoettner, C., Podesser, B. K., Gail, A., Farina, D., Cederna, P. S., et al. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.01442 · Cited by 17
Self-citationRegenerative peripheral nerve interfaces (RPNIs): current status and future direction
Burke, K. L., Kung, T. A., Hooper, R. C., Kemp, S. W. P., & Cederna, P. S. (2022) · Plastic and Aesthetic Research · doi:10.20517/2347-9264.2022.26 · Cited by 15
Self-citationGonzález-Prieto, J., Cristóbal, L., Arenillas, M., Giannetti, R., Frías, J. D. M., Rivas, E. A., Barbero, E. S., Gutiérrez-Pecharromán, A., Montero, F. D., & Maldonado, A. A. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms25021141 · Cited by 15
Spike detection: The first step towards an ENG-based neuroprosheses
Noce, E., Ciancio, A. L., & Zollo, L. (2018) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2018.07.008 · Cited by 12
Lee, H., Lee, Y. A., Jiang, L., Chen, J., Lam, W., & Lo, Y.-T. (2025) · Advanced Technology in Neuroscience · doi:10.4103/atn.atn-d-25-00007 · Cited by 5
Svientek, S. R., Wisely, J. P., Dehdashtian, A., Bratley, J. V., Cederna, P. S., & Kemp, S. W. P. (2022) · Journal of Visualized Experiments · doi:10.3791/63222 · Cited by 9
Self-citationSammut, S., Koh, R. G. L., & Zariffa, J. (2021) · Sensors · doi:10.3390/s21020506 · Cited by 9
Merging Humans and Neuroprosthetics through Regenerative Peripheral Nerve Interfaces
Tian, Y., Vaskov, A. K., Adidharma, W., Cederna, P. S., & Kemp, S. W. P. (2024) · Seminars in Plastic Surgery · doi:10.1055/s-0044-1779028 · Cited by 8
Self-citationVujaklija, I., & Farina, D. (2022) · Springer eBooks · doi:10.1007/978-3-031-10355-1_41 · Cited by 8
Feasibility of Using the Utah Array for Long-Term Fully Implantable Neuroprosthesis Systems
Bullard, A. J. (2019) · Deep Blue (University of Michigan) · Cited by 8
Self-citationIn-silico development and assessment of a Kalman filter motor decoder for prosthetic hand control
Gamal, M., Mousa, M. H., Eldawlatly, S., & Elbasiouny, S. M. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104353 · Cited by 6
Merging Neuroscience and Engineering Through Regenerative Peripheral Nerve Interfaces
Wang, M. J., Kung, T. A., Snyder‐Warwick, A. K., & Cederna, P. S. (2025) · Prosthesis · doi:10.3390/prosthesis7040097 · Cited by 5
Self-citationClinical Basis for Creating an Osseointegrated Neural Interface
Karczewski, A. M., Zeng, W., Stratchko, L. M., Bachus, K. N., Poore, S. O., & Dingle, A. M. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.828593 · Cited by 5
Hard-wired Epimysial Recordings from Normal and Reinnervated Muscle Using a Bone-anchored Device
Lancashire, H. T., Al-Ajam, Y., Dowling, R., Pendegrass, C. J., & Blunn, G. W. (2019) · Plastic & Reconstructive Surgery Global Open · doi:10.1097/gox.0000000000002391 · Cited by 4
Design Methodology for Energy-constrained AI Edge Inference in Implantable Medical Devices
Filho, J. S., Xu, J., Kanchwala, M., O’Leary, G., Zariffa, J., & Genov, R. (2023) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas58349.2023.10388749 · Cited by 3
A comparison of extraneural approaches for selective recording in the peripheral nervous system
Koh, R. G. L., Jabban, L., Fukushi, M., Adeyinka, I. C., Zariffa, J., & Metcalfe, B. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871727 · Cited by 3
A Compact 16-Channel Neural Signal Recorder with Wireless Power and Data Transmission
Huang, H., Luo, D., Song, W., Zhang, M., Wang, Z., & Li, G. (2023) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas46773.2023.10181720 · Cited by 2
Regenerative Peripheral Nerve Interfaces for Treatment of Symptomatic Neuromas
Kumar, N. G., Cederna, P. S., & Kung, T. A. (2024) · Springer eBooks · doi:10.1007/978-3-031-59758-9_18 · Cited by 2
Self-citationWang, M. J., Cubillos, L. H., Kung, T. A., Kemp, S. W. P., Snyder‐Warwick, A. K., & Cederna, P. S. (2025) · Artificial Intelligence Surgery · doi:10.20517/ais.2025.03 · Cited by 2
Self-citationBiotic‐Abiotic Interface Engineering for Peripheral Nerve Modulation and Repair
Jekal, J., Park, J. T., Kim, E., Lee, Y., & Jang, K. (2025) · Small Methods · doi:10.1002/smtd.202501620 · Cited by 2
Sammut, S., Koh, R. G. L., & Zariffa, J. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176736 · Cited by 2
Training Movement Velocity Significantly Affects the Performance of Myoelectric Control
Tully, T. N., Nelson, A. E., & George, J. A. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3610352 · Cited by 2
Segil, J. L., Lukyanenko, P., Lambrecht, J., Weir, R. F. F., & Tyler, D. J. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630845 · Cited by 2
Modulating and Monitoring Autonomic Nerves for Glycemic Control
Jiman, A. A. (2020) · Deep Blue (University of Michigan) · Cited by 2
Chen, T., Mohanty, A. J., Yucheng, T., Kemp, S. W. P., Cederna, P. S., & Kung, T. A. (2026) · Expert Review of Medical Devices · doi:10.1080/17434440.2026.2615785 · Cited by 1
Self-citationSammut, S., Koh, R. G. L., & Zariffa, J. (2020) · Asilomar Conference on Signals, Systems and Computers (ACSSC) · doi:10.1109/ieeeconf51394.2020.9443545 · Cited by 1
Emergence of Nerve Interfaces with Robotic Applications
Burke, K. L., Dumanian, G. A., & Cederna, P. S. (2024) · Springer eBooks · doi:10.1007/978-3-031-57132-9_6 · Cited by 1
Self-citationRestoring Fine Motor Prosthetic Hand Control via Peripheral Neural Technology
Vu, P. P. (2019) · Deep Blue (University of Michigan) · Cited by 1
Self-citationVaskov, A. K., Vu, P. P., Davis, A. J., Kung, T. A., Cederna, P. S., & Chestek, C. A. (2020) · UNB Conferences · doi:10.57922/mec.38
Self-citationKumar, N. G., Cederna, P. S., & Kung, T. A. (2021) · Techniques in Orthopaedics · doi:10.1097/bto.0000000000000542
Self-citationAutomatic Segmentation and Three-dimensional Reconstruction of Fascicles in Peripheral Nerves
Tovbis, D. (2019) · TSpace (University of Toronto)
Implantable Neural Interfaces for Direct Control of Hand Prostheses
Vaskov, A. K. (2021) · Deep Blue (University of Michigan) · doi:10.7302/2843
Preciado, J. D. M., Gámiz, D. G., Royo, M., & Hontanilla, B. (2026) · PLoS ONE · doi:10.1371/journal.pone.0350845 · Cited by 2
Brain Machine Interfaces for the Control of Prosthetic Fingers
Chestek, C. A. (2025) · Biosystems & biorobotics · doi:10.1007/978-3-031-77588-8_1
Self-citationSammut, S. (2020) · TSpace (University of Toronto)
Regenerative Peripheral Nerve Interface and the Future of Intuitive Control
Wang, M. J., Kung, T. A., Cederna, P. S., & Kemp, S. W. P. (2026) · Hand Clinics · doi:10.1016/j.hcl.2026.03.009
Self-citationGonzález-Prieto, J., Arenillas, M., Barbero, E. S., Pecharromán, A. G., Muñoz, J. D., Rivas, E. A., Morillo, M. D. C., Cristóbal, L., Giannetti, R., & Maldonado, A. A. (2026) · Journal of Translational Medicine · doi:10.1186/s12967-026-08453-y
A Miniaturized Neural Recording Microprobe Using an On-Chip Antenna for RF Uplink Communication
Atzeni, G., Lim, J., Liao, J., Lee, J., Letner, J. G., Mazzarella, G., Fanti, A., Kim, H.-S., Chestek, C. A., Phillips, J., et al. (2026) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2026.3718769
Self-citationEvaluation of a Virtual Box and Blocks Test (BBT) for Assessing Upper Limb Prosthetic Dexterity
Carlson, J. S., Surkin, J. A. W., & Gates, D. H. (2026) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob66782.2026.11681215 · Cited by 1
Lee, O. G., Cubillos, L. H., Temmar, H., Wallace, D. M., Hite, A., DeMatteo, J. C., Costello, J. T., Joseph, J. J., Kelberman, M. M., Copenhaver, M. G., et al. (2026) · Bioelectronic Medicine · doi:10.1186/s42234-026-00217-9
Self-citation
Metadata
- Authors
- Vu, P. P., Irwin, Z. T., Bullard, A. J., Ambani, S. W., Sando, I. C., Urbanchek, M. G., Cederna, P. S., & Chestek, C. A.
- Affiliations
- University of Michigan (US)
- ORCID
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2018-02
- Volume
- 26
- Issue
- 2
- Pages
- 515-526
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2770125713
- Cited by
- 61
- References
- 56
- Citations by year
- 2026: 4 · 2025: 5 · 2024: 6 · 2023: 4 · 2022: 10 · 2021: 10 · 2020: 11 · 2019: 10 · 2018: 1
- FWCI
- 2.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Wallace H. Coulter Foundation
- Plastic Surgery Foundation
- Frederick A. Coller Surgical Society
- NSF Graduate Research Fellowships
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- regenerative peripheral nerve interface, Kalman filter, intramuscular electromyography, transradial amputation, upper limb prosthesis, rhesus monkeys, single-unit activity, recalibration, non-human primates
- MeSH terms
- Algorithms, Animals, Artificial Limbs, Calibration, Electric Stimulation, Electromyography, Fingers, Macaca mulatta, Peripheral Nerves, Prosthesis Design, Psychomotor Performance, User-Computer Interface, Upper Extremity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.