A Wireless Multi-Channel Peripheral Nerve Signal Acquisition System-on-Chip
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The adoption of chronic implantable peripheral nerve-based prosthetic devices is currently hampered by the lack of a highly integrated neural signal acquisition system-on-chip (SoC). We report a ten-channel peripheral nervous system (PNS) electroneurogram (ENG) signal acquisition SoC within an implantable package. Requiring only four off-chip capacitors, this SoC can be co-encapsulated with flexible nerve electrodes and a resonant coil antenna to form a 3.4 cm3 and 3.9 g implantable device for chronic ENG acquisition. This SoC is inductively powered and controlled through a resonant coil at 22 MHz and transmits the digitized neural signal through a near-infrared LED (NIR-LED). Fabricated in 0.18-μm CMOS, each amplifier channel exhibits an input referred noise of 1.9 μVrms and a noise efficiency factor (NEF) of 4.0 within the signal bandwidth of 5.5 kHz. Each amplifier channel within the SoC is digitized with 10-bit resolution at 17.5 ksps, and the total power consumption (SoC and NIR-LED) is 4.4 mW when the NIR-LED is driven at 3 Mb/s. An electrode impedance measurement circuit with <;10% magnitude and <;8° angle error for measuring impedances up to 1 MQ is also incorporated in this SoC. This wireless, low noise ENG acquisition SoC package has been validated in vivo while implanted on a rodent to acquire ENG from its sciatic nerve.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Restoring cortical control of functional movement in a human with quadriplegia
Bouton, C. E., Shaikhouni, A., Annetta, N. V., Bockbrader, M. A., Friedenberg, D. A., Nielson, D. M., Sharma, G., Sederberg, P. B., Glenn, B. C., Mysiw, W. J., et al. (2016) · Nature · doi:10.1038/nature17435 · Cited by 924 · cited 1×
“, recording from proximal nerves while performing functional electrical stimulation of hand muscles in paralyzed patients [15].”
BackgroundOptimal Frequency for Wireless Power Transmission Into Dispersive Tissue
Poon, A. S. Y., O'Driscoll, S., & Meng, T. H. (2010) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2010.2044310 · Cited by 469 · cited 11×
“Transcutaneous attenuation of electromagnetic fields remains minimal even at 22 MHz [42].”
BackgroundInfluentialA 1-V 450-nW fully integrated programmable biomedical sensor interface chip.
Zou, X., Xu, X., Yao, L., & Lian, Y. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2014707 · Cited by 414 · cited 1×
“This is the main contribution to the signal distortion [33], especially when the output signal swing is large.”
BackgroundPolytrodes: High-Density Silicon Electrode Arrays for Large-Scale Multiunit Recording
Blanche, T. J., Spacek, M. A., Hetke, J. F., & Swindale, N. V. (2005) · Journal of Neurophysiology · doi:10.1152/jn.01023.2004 · Cited by 282
Micera, S., Rossini, P. M., Rigosa, J., Citi, L., Carpaneto, J., Raspopovic, S., Tombini, M., Cipriani, C., Assenza, G., Carrozza, M. C., et al. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-53 · Cited by 100
A Compact, Low Input Capacitance Neural Recording Amplifier
Ng, K. A., & Xu, Y. P. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2280066 · Cited by 81 · cited 2×
“1 dB) by turning on switches G2 to enable a T-capacitor feedback path [29].”
BackgroundSelf-citationDesign of a low-noise preamplifier for nerve cuff electrode recording
Rieger, R., Taylor, J., Demosthenous, A., Donaldson, N., & Langlois, P. J. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.814437 · Cited by 78 · cited 2×
“Very low noise peripheral nerve ENG amplifiers were previously reported in [25] and [26], and were designed to acquire very low amplitude signals (<10 μVpp) [27] from extraneural electrodes.”
BackgroundVu, P. P., Irwin, Z. T., Bullard, A. J., Ambani, S. W., Sando, I. C., Urbanchek, M. G., Cederna, P. S., & Chestek, C. A. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2772961 · Cited by 61
Very Low-Noise ENG Amplifier System Using CMOS Technology
Rieger, R., Schuettler, M., Pal, D., Clarke, C., Langlois, P., Taylor, J., & Donaldson, N. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.886731 · Cited by 57
Stable Detection of Movement Intent From Peripheral Nerves: Chronic Study in Dogs
Dweiri, Y. M., Eggers, T. E., Gonzalez-Reyes, L. E., Drain, J., McCallum, G. A., & Durand, D. M. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2607520 · Cited by 44 · cited 13×
“Very low noise peripheral nerve ENG amplifiers were previously reported in [25] and [26], and were designed to acquire very low amplitude signals ( 10 μVpp) [27] from extraneural electrodes.”
BackgroundInfluential
Cited by
ElAnsary, M., Xu, J., Filho, J. S., Dutta, G., Long, L., Tejeiro, C., Shoukry, A., Tang, C., Kilinc, E., Joshi, J., et al. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3113354 · Cited by 48
An ultra-low-power neural signal acquisition analog front-end IC
Tran, L., & Cha, H.-K. (2021) · Microelectronics Journal · doi:10.1016/j.mejo.2020.104950 · Cited by 26
High-density neural recording system design
Lee, H.-S., Eom, K., Park, M., Ku, S.-B., Lee, K., & Lee, H.-M. (2022) · Biomedical Engineering Letters · doi:10.1007/s13534-022-00233-z · Cited by 17
Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11
“Alternative structures such as the fascicle-selective, die-on-cuff interface, flat-interface cuff electrodes (FINE) and thin-film longitudinal intra-fascicular electrodes (tfLIFE) have also been developed with ICs to achieve selective, active neural interfaces [54], [55], [56], [57].”
Metadata
- Authors
- Ng, K. A., Yuan, C., Rusly, A., Do, A.-T., Zhao, B., Liu, S.-C., Peh, W. Y. X., Thow, X. Y., Voges, K., Lee, S., Gammad, G. G. L., Leong, K.-W., Ho, J. S., Bossi, S., Taverni, G., Cutrone, A., Yen, S.-C., & Xu, Y. P.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2019-08
- Volume
- 54
- Issue
- 8
- Pages
- 2266-2280
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2944787947
- Cited by
- 47
- References
- 10
- FWCI
- 1.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Wireless Multi-Channel Peripheral Nerve Signal Acquisition System-on-Chip. https://app.cochat.ai/papers/10.1109/jssc.2019.2909158
- The paper
- Ng, K. A., Yuan, C., Rusly, A., Do, A.-T., Zhao, B., Liu, S.-C., Peh, W. Y. X., Thow, X. Y., Voges, K., Lee, S., Gammad, G. G. L., Leong, K.-W., Ho, J. S., Bossi, S., Taverni, G., Cutrone, A., Yen, S.-C., & Xu, Y. P. (2019). A Wireless Multi-Channel Peripheral Nerve Signal Acquisition System-on-Chip. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2019.2909158
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.