Characterization of Parkinsonian Hand Tremor and Validation of a High-Order Tremor Estimator
The DOI matches its Crossref record; 59 of the 72 references it cites were found in a registry or an index.
Abstract
Recent progress in wearable technology has made wearable tremor suppression devices (WTSDs) for Parkinson's patients a potentially viable alternative solution for tremor management. So far, in contrast to wrist and elbow tremor, finger tremors have not been studied in depth despite the huge impact that they have on a patient's daily life. In addition, more evidence has been found showing that the performance of current tremor estimators may be limited by their model order due to the multiple harmonics present in tremor. The aim of this paper is to characterize finger and wrist tremor in both the time and frequency domains, and to propose a high-order tremor estimation algorithm. Tremor magnitudes are reported in the forms of linear acceleration, angular velocity, and angular displacement. The activation of forearm flexor and extensor muscles is also investigated. The frequency analysis shows that Parkinsonian tremors produce oscillations of the hand with pronounced harmonics. At last, a high-order weighted-frequency Fourier linear combiner (WFLC)-based Kalman filter is proposed. The percentage estimation accuracy achieved from the proposed estimator is 96.3 ± 1.7%, showing average improvements of 28.5% and 48.9% over its lower-order counterpart and the WFLC. The proposed estimator shows promise for use in a WTSD.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The evaluation showed that the eHWFLC-KF achieved better performance than its lower-order counterpart, since parkinsonian tremor consists of multiple frequencies [24], [30].”
From Real-Time Performance Assessment of High-Order Tremor Estimators Used in a Wearable Tremor Suppression Device (2022) · cites this paper as [29]
In the citing paper
“only 11 out of 18 postural tremor datasets present multiple harmonics [29]”
From Real-Time Performance Assessment of High-Order Tremor Estimators Used in a Wearable Tremor Suppression Device (2022) · cites this paper as [29]
In the citing paper
“Furthermore, their proposed feature of adaptively selecting a tremor frequency band is unnecessary in this application, as the frequency band of pathological tremor is well determined and fairly constant [29], [35].”
From Real-Time Performance Assessment of High-Order Tremor Estimators Used in a Wearable Tremor Suppression Device (2022) · cites this paper as [29]
In the citing paper
“most of the parkinsonian resting tremor (17 out of 18 datasets) contains multiple harmonics [29]”
From Real-Time Performance Assessment of High-Order Tremor Estimators Used in a Wearable Tremor Suppression Device (2022) · cites this paper as [29]
Citations
Cites
Goetz, C. G., Tilley, B. C., Shaftman, S. R., Stebbins, G. T., Fahn, S., Martinez‐Martin, P., Poewe, W., Sampaio, C., Stern, M. B., Dodel, R., et al. (2008) · Movement Disorders · doi:10.1002/mds.22340 · Cited by 7,536 · cited 1×
“The neurologist administered the MDS-Unified Parkinson’s Disease Rating Scale (MDS-UPDRS): Part III (Motor Assessment) (1) to quantify the severity of the disease [49], including the severity of the tremor, and to select the hand with the greatest amount of tremor for data collection.”
MethodConsensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981 · cited 1×
“to stay constant with slight variations; however, the amplitude of the tremor varies from person to person [1], [26], [32], [33].”
BackgroundMorgan, D. (1986) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1986.1164869 · Cited by 1,681
Rascol, O., Brooks, D. J., Korczyn, A. D., De Deyn, P. P., Clarke, C. E., & Lang, A. E. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005183422004 · Cited by 1,539 · cited 1×
“Medication is the mainstay of treatment; however, it often causes side effects and shows decreased effectiveness over time [5], [6].”
BackgroundDesign and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349 · cited 1×
“In most of the previous studies [24], [59], parkinsonian tremor was considered and reported as a mono-harmonic signal, its fundamental frequency lying within the range of 4 to 12 Hz.”
ResultAdaptive cancelling of physiological tremor for improved precision in microsurgery
Riviere, C. N., Rader, R. S., & Thakor, N. V. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686791 · Cited by 260 · cited 3×
“studies [21], [30], [42]–[44], [51] the WFLC was used to estimate only the fundamental frequency.”
BackgroundMethodThe dynamics of resting and postural tremor in Parkinson's disease
Vaillancourt, D. E., & Newell, K. M. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00467-3 · Cited by 210 · cited 2×
“This result is in line with the results from other studies [54], [60].”
BackgroundResultAdaptive Fourier estimation of time-varying evoked potentials
Vaz, C. A., & Thakor, N. V. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.18751 · Cited by 159
Preventing levodopa-induced dyskinesias.
Olanow, C. W., & Obeso, J. A. (2000) · PubMed · Cited by 155
Attenuation of pathological tremors by functional electrical stimulation I: Method
Prochazka, A., Elek, J., & Javidan, M. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368521 · Cited by 150 · cited 2×
“that applies functional electrical stimulation [16]–[23].”
Background
Research works printed but not linked: 5
- gonzález, 1995, A new approach to suppressing abnormal tremor through signal equalization, Proc RESNA Annu Conf, 707
- rocon, 2005, Estimation of biomechanical characteristics of tremorous movements based on gyroscopes, Virtual Reality and Assistive Technology, 138
- elble, 1990, Tremor, 54
- pons, 2012, A wearable neuroprosthesis for the suppression of pathological tremor, IEEE Life Sci Newslett
- 2012, Android SDK
Cited by
Smartwatch for the analysis of rest tremor in patients with Parkinson's disease
Blanco, R. L., Velasco, M. A., Méndez-Guerrero, A., Romero, J. P., del Castillo, M. D., Serrano, J. I., Rocón, E., & Benito‐León, J. (2019) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2019.04.011 · Cited by 97
Design and Preliminary Performance Assessment of a Wearable Tremor Suppression Glove
Zhou, Y., Ibrahim, A. H., Hardy, K. G., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3080622 · Cited by 37
Self-citationReal-Time Voluntary Motion Prediction and Parkinson’s Tremor Reduction Using Deep Neural Networks
Ibrahim, A. H., Zhou, Y., Jenkins, M. E., Trejos, A. L., & Naish, M. D. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3097007 · Cited by 34
Self-citationMenguc, E. C., cnar, S., Xiang, M., & P. Mandic, D. (2021) · IEEE Signal Processing Letters · doi:10.1109/lsp.2021.3097279 · Cited by 25
Peripherical Electrical Stimulation for Parkinsonian Tremor: A Systematic Review
Meng, L., Jin, M., Zhu, X., & Ming, D. (2022) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2022.795454 · Cited by 30
A Tremor Suppression and Noise Removal Algorithm for Microscopic Robot-Assisted Cataract Surgery
Bian, G., Wang, J., Fu, P., Wei, B.-T., Li, M., & Li, Z. (2023) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2023.3254161 · Cited by 22
Movement Disorders and Smart Wrist Devices: A Comprehensive Study
Caroppo, A., Manni, A., Rescio, G., Carluccio, A. M., Siciliano, P. A., & Leone, A. (2025) · Sensors · doi:10.3390/s25010266 · Cited by 25
Using Deep Learning for Task and Tremor Type Classification in People with Parkinson’s Disease
Farhani, G., Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2022) · Sensors · doi:10.3390/s22197322 · Cited by 24
“To assess these three tremors, the participants were asked to perform six different tasks as follows [46]:”
MethodSelf-citationZhang, Z., Chu, B., Liu, Y., Ren, H., Li, Z., & Owens, D. H. (2021) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2021.3111107 · Cited by 18
“Research results have shown that for different patients, tremor can have multiple frequencies, or even a frequency band [22], [23].”
BackgroundIbrahim, A., Zhou, Y., Jenkins, M. E., Luisa Trejos, A., & Naish, M. D. (2020) · 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176132 · Cited by 15
“ca to perform ADLs, yet the performance of these devices is limited by the tremor models they use [7].”
BackgroundInfluentialSelf-citationReal time estimation and suppression of hand tremor for surgical robotic applications
Kumar, A., Kumar, S., Kaushik, A. K., Kumar, A., & Saini, J. S. (2020) · Microsystem Technologies · doi:10.1007/s00542-019-04736-1 · Cited by 17
“It can affect various parts of the body such as hands, head, tongue, trunk and legs and can disturb the routine working of humans (Zhou et al. 2018; Wang et al. 2017, 2018a; Cole et al. 2014; Rocon et al. 2007; Herrnstadt and Menon 2016).”
BackgroundDeveloping an Assisting Device to Reduce the Vibration on the Hands of Elders
Van, H. P., & Ngo, H. Q. T. (2021) · Applied Sciences · doi:10.3390/app11115026 · Cited by 16
“In [37], the max value of the moment on the precession axis is:”
BackgroundMethodEnergetic Passivity Decoding of Human Hip Joint for Physical Human-Robot Interaction
Atashzar, S. F., Huang, H.-Y., Duca, F. D., Burdet, E., & Farina, D. (2020) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2020.3010459 · Cited by 15
“To achieve this goal, robotic systems should respond promptly to the patient’s voluntary motions [10], [11] while inhibiting involuntary actions [12], [13], [14], [15], [16].”
BackgroundLin, F., Wang, Z., Zhao, H., Qiu, S., Liu, R., Shi, X., Wang, C., & Yin, W. (2023) · IEEE Transactions on Cognitive and Developmental Systems · doi:10.1109/tcds.2023.3266812 · Cited by 15
“Zhou et al. [32] proposed a weighted frequency Fourier linear combiner (WFLC) to estimate the frequency and amplitude of earthquakes.”
BackgroundFitts’ Law Based Performance Metrics to Quantify Tremor in Individuals With Essential Tremor
Kim, J., Wichmann, T., Inan, O. T., & DeWeerth, S. P. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3129989 · Cited by 16
Berbakov, L., Jovanović, Č., Svetel, M. V., Vasiljević, J., Dimić, G., & Radulović, N. (2019) · Sensors · doi:10.3390/s19194246 · Cited by 17
“[15], where the results show that Parkinsonian tremor produce oscillations of the hand with different harmonics.”
BackgroundAnalysis of the Effect of Common Disturbances on the Safety of a Wearable Tremor Suppression Device
Zhou, Y., Ibrahim, A. H., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2021) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2021.3062592 · Cited by 14
“BMFLC, and the eHWFLC-KF were selected according to the values reported in [13], [15] and [19] with fine adjustments to achieve the tremor suppression performance as close as possible”
BackgroundMethodInfluentialSelf-citationMultimodal Tremor Suppression of the Wrist Using FES and Electric Motors–A Simulation Study
Habibollahi, Z., Zhou, Y., Jenkins, M. E., Garland, S. J., Naish, M. D., & Trejos, A. L. (2023) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2023.3316607 · Cited by 11
“), using a dataset from 18 participants (11 males, 7 females) with parkinsonian tremor [26].”
MethodSelf-citationTwo-channel lstm for severity rating of parkinson’s disease using 3d trajectory of hand motion
Zhao, A., & Li, J. (2022) · Multimedia Tools and Applications · doi:10.1007/s11042-022-12659-9 · Cited by 12
“The hand of patients with Parkinson’s disease is easily affected by muscle stiffness, and often presents a peculiar flexion posture, which makes it difficult to unfold the palm; while the extension of small joints between other fingers makes it difficult to clench the palm [24, 25, 36].”
BackgroundZhou, Y., Habibollahi, Z., Ibrahim, A., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3211450 · Cited by 8
“chosen according to the values reported in [22], and the bandwidth of the BMFLC was selected according to the tremor frequency reported in [29].”
BackgroundMethodResultInfluentialSelf-citationParkinson's Tremor Onset Detection and Active Tremor Classification Using a Multilayer Perceptron
Ibrahim, A., Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2020) · 2020 IEEE Canadian Conference on Electrical and Computer Engineering (CCECE) · doi:10.1109/ccece47787.2020.9255672 · Cited by 8
“Parkinsonian tremor consists of three harmonics with frequencies in the range of 3 to 17 Hz [5].”
BackgroundSelf-citationDaemi, P., Zhou, Y., Inzunza, K., Naish, M. D., Price, A. D., & Trejos, A. L. (2020) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob49111.2020.9224290 · Cited by 7
Self-citationZhou, Y., Daemi, P., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2024) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2024.3350769 · Cited by 6
“Following the fault detection schema, an Enhanced High-order Weighted-frequency Fourier Linear Combiner-based Kalman Filter [34] was configured to extract the tremor and voluntary motion from the filtered motion.”
BackgroundMethodInfluentialSelf-citationReal-World Parkinson’s Hand Tremor Detection Using Ensemble Learning Techniques
Hur, S., Zhang, J., Kim, M.-H., & Chung, T. (2025) · IEEE Access · doi:10.1109/access.2025.3534293 · Cited by 7
A Review of Techniques Used to Suppress Tremor
Saleh, S. K., Mohammed, S. L., & Al-Askery, A. J. (2022) · Journal of Techniques · doi:10.51173/jt.v4i4.774 · Cited by 9
Zhang, Z., Huo, B., Liu, Y., Dong, A., & Yu, H. (2024) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2024.3450599 · Cited by 12
FES based wrist tremor suppression using multi-periodic repetitive control
Zhang, Z., Chu, B., Liu, Y., & Owens, D. H. (2020) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2020.12.2739 · Cited by 5
“Research results on various patients showed that tremor is a multiple frequency signals, or even a signal with frequency band (Zhou et al. (2018)).”
BackgroundYousef, M., Hafizh, M., Sassi, S., & Muthalif, A. G. A. (2023) · Journal of Vibration and Control · doi:10.1177/10775463231158196 · Cited by 4
“In literature, a standard classi fi cation is through the use of frequency; tremors can be classi fi ed as postural (5 – 9 Hz), rest (3 – 6 Hz), or action (3 – 10 Hz) (Charles et al., 1999; Van et al., 2021; Y Zhou et al., 2018a).”
BackgroundMultiple Order Fourier Linear Combiner: Estimating Phase Shift for Real-Time Vibration Compensation
He, Y., Fan, Y., & Tan, U.-X. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3179703 · Cited by 3
Xiao, F., Zhong, B., Wu, Y., & Wang, Y. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3222299 · Cited by 2
“This has been commonly used in the research of pathological tremor [10], [39].”
BackgroundMethodZhang, Z., Huo, B., Liu, Y., Dong, A., & Yu, H. (2024) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2024.3427638 · Cited by 5
“Several repetitive control approaches have been devised for tremor suppression based on FES for different types of tremor signals [11], [12].”
da Silva, R. M., Vila, S. A., Toque, E., Gutiérrez, C., Torres, S., Elías, D. A., & Abarca, V. E. (2025) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-89510-4_5 · Cited by 2
Variability of Parkinsonian Tremor During Different Tasks and Under External Interference
Habibollahi, Z., Zhou, Y., Jenkins, M. E., Garland, S. J., Friedman, E., Naish, M. D., & Trejos, A. L. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3470556 · Cited by 2
“The first experiment aimed to collect tremor data during different tasks and compare tremor features [25].”
MethodSelf-citationMechatronic Devices for Upper Limb Tremor
Zhou, Y., Daemi, P., Edmonds, B. P. R., Habibollahi, Z., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2023) · Contemporary clinical neuroscience · doi:10.1007/978-3-031-26128-2_22 · Cited by 1
Self-citationZhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871546 · Cited by 1
“extract the user’s voluntary motion and tremor motion [12].”
BackgroundMethodInfluentialSelf-citationFace Validity and Usability Evaluation of a Wearable Upper-Limb Motion Sensing System for Home Use
Kalsi, J., Zhou, Y., Jenkins, M. E., Donelle, L., Trejos, A. L., & Naish, M. D. (2025) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr66766.2025.11063173
“Since the maximum frequency of typical voluntary motion is 4 Hz [5] and tremor is generally less than 12 Hz [6], the sampling frequency (28.6 Hz) is sufficient to capture both types of motion [13].”
InfluentialSelf-citationA Closed-Loop Deep Brain Stimulation Biomedical Model of Parkinson’s Disease
(2024) · doi:10.1109/cibcb58642.2024.10702117
“For example, Zhou et al. [29] showed that postural tremors are concentrated during certain intervals of time, surrounded by short periods of tremor-free movements.”
BackgroundWang, Y., Ou, S., & Gao, Y. (2022) · Chinese Control Conference (CCC) · doi:10.23919/ccc55666.2022.9901690
Gong, K., Jiang, L., Qiu, S., Tang, X., Wu, W., Yang, B., Guo, W., & Liu, H. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3643067 · Cited by 2
“In parallel, Zhou et al. [25] characterized Parkinsonian hand tremor and validated high-order WFLC (HWFLC)-type estimators and later presented a wearable suppression glove with preliminary performance assessment [26], demonstrating algorithmic and device-level advances on targeted tasks.”
InfluentialSakib, M., Khanom, S., Nahadi, T. M., Mithu, A. M., Ahmed, N., Islam, M., Sarker, T., Chisty, N., Ahad, A., Hossain, M. M., et al. (2025) · Biomedical Engineering Letters · doi:10.1007/s13534-025-00526-z · Cited by 2
Pathological Tremor Suppression Based on Adaptive Sliding Dual-Band FLC and LADRC
Li, T., Wu, Y. H., Ren, K., Chen, Z., & Zhao, J. (2026) · Chinese Control and Decision Conference (CCDC) · doi:10.1109/ccdc69976.2026.11560641
“Third, the algorithm couples the frequency and weight updates [7,8,10].”
Influential
Metadata
- Authors
- Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L.
- Affiliations
- Western University (CA)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2018-09
- Volume
- 26
- Issue
- 9
- Pages
- 1823-1834
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2883932938
- Cited by
- 42
- References
- 72
- Citations by year
- 2026: 2 · 2025: 6 · 2024: 5 · 2023: 5 · 2022: 9 · 2021: 7 · 2020: 6 · 2019: 2
- FWCI
- 1.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- Scholarship@Western (Western University) (submittedVersion)
- Funders
- Western University
- Natural Sciences and Engineering Research Council of Canada (RGPIN-2014-03815)
- Ontario Ministry of Economic Development, Trade and Employment and the Ontario Ministry of Research and Innovation through the Early Researcher Award
- Peter C. Maurice Research Fellowship in Biomedical Engineering
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Effects of Vibration on Health
- Keywords
- finger tremor, Kalman filter
- MeSH terms
- Wearable Electronic Devices, Aged, Aged, 80 and over, Algorithms, Biomechanical Phenomena, Elbow, Female, Fingers, Fourier Analysis, Hand, Humans, Male, Middle Aged, Tremor, Wrist, Reproducibility of Results, Parkinsonian Disorders
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.