Characterization of Parkinsonian Hand Tremor and Validation of a High-Order Tremor Estimator
The DOI matches its Crossref record; 59 of the 72 references it cites were found in a registry or an index.
Abstract
Recent progress in wearable technology has made wearable tremor suppression devices (WTSDs) for Parkinson's patients a potentially viable alternative solution for tremor management. So far, in contrast to wrist and elbow tremor, finger tremors have not been studied in depth despite the huge impact that they have on a patient's daily life. In addition, more evidence has been found showing that the performance of current tremor estimators may be limited by their model order due to the multiple harmonics present in tremor. The aim of this paper is to characterize finger and wrist tremor in both the time and frequency domains, and to propose a high-order tremor estimation algorithm. Tremor magnitudes are reported in the forms of linear acceleration, angular velocity, and angular displacement. The activation of forearm flexor and extensor muscles is also investigated. The frequency analysis shows that Parkinsonian tremors produce oscillations of the hand with pronounced harmonics. At last, a high-order weighted-frequency Fourier linear combiner (WFLC)-based Kalman filter is proposed. The percentage estimation accuracy achieved from the proposed estimator is 96.3 ± 1.7%, showing average improvements of 28.5% and 48.9% over its lower-order counterpart and the WFLC. The proposed estimator shows promise for use in a WTSD.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The evaluation showed that the eHWFLC-KF achieved better performance than its lower-order counterpart, since parkinsonian tremor consists of multiple frequencies [24], [30].”
From Real-Time Performance Assessment of High-Order Tremor Estimators Used in a Wearable Tremor Suppression Device (2022) · cites this paper as [29]
In the citing paper
“only 11 out of 18 postural tremor datasets present multiple harmonics [29]”
From Real-Time Performance Assessment of High-Order Tremor Estimators Used in a Wearable Tremor Suppression Device (2022) · cites this paper as [29]
In the citing paper
“Furthermore, their proposed feature of adaptively selecting a tremor frequency band is unnecessary in this application, as the frequency band of pathological tremor is well determined and fairly constant [29], [35].”
From Real-Time Performance Assessment of High-Order Tremor Estimators Used in a Wearable Tremor Suppression Device (2022) · cites this paper as [29]
In the citing paper
“most of the parkinsonian resting tremor (17 out of 18 datasets) contains multiple harmonics [29]”
From Real-Time Performance Assessment of High-Order Tremor Estimators Used in a Wearable Tremor Suppression Device (2022) · cites this paper as [29]
Citations
Cites
Goetz, C. G., Tilley, B. C., Shaftman, S. R., Stebbins, G. T., Fahn, S., Martinez‐Martin, P., Poewe, W., Sampaio, C., Stern, M. B., Dodel, R., et al. (2008) · Movement Disorders · doi:10.1002/mds.22340 · Cited by 7,536 · cited 1×
“The neurologist administered the MDS-Unified Parkinson’s Disease Rating Scale (MDS-UPDRS): Part III (Motor Assessment) (1) to quantify the severity of the disease [49], including the severity of the tremor, and to select the hand with the greatest amount of tremor for data collection.”
MethodConsensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981 · cited 1×
“to stay constant with slight variations; however, the amplitude of the tremor varies from person to person [1], [26], [32], [33].”
BackgroundMorgan, D. (1986) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1986.1164869 · Cited by 1,681
Rascol, O., Brooks, D. J., Korczyn, A. D., De Deyn, P. P., Clarke, C. E., & Lang, A. E. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005183422004 · Cited by 1,539 · cited 1×
“Medication is the mainstay of treatment; however, it often causes side effects and shows decreased effectiveness over time [5], [6].”
BackgroundDesign and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349 · cited 1×
“In most of the previous studies [24], [59], parkinsonian tremor was considered and reported as a mono-harmonic signal, its fundamental frequency lying within the range of 4 to 12 Hz.”
ResultAdaptive cancelling of physiological tremor for improved precision in microsurgery
Riviere, C. N., Rader, R. S., & Thakor, N. V. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686791 · Cited by 260 · cited 3×
“studies [21], [30], [42]–[44], [51] the WFLC was used to estimate only the fundamental frequency.”
BackgroundMethodThe dynamics of resting and postural tremor in Parkinson's disease
Vaillancourt, D. E., & Newell, K. M. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00467-3 · Cited by 210 · cited 2×
“This result is in line with the results from other studies [54], [60].”
BackgroundResultAdaptive Fourier estimation of time-varying evoked potentials
Vaz, C. A., & Thakor, N. V. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.18751 · Cited by 159
Preventing levodopa-induced dyskinesias.
Olanow, C. W., & Obeso, J. A. (2000) · PubMed · Cited by 155
Attenuation of pathological tremors by functional electrical stimulation I: Method
Prochazka, A., Elek, J., & Javidan, M. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368521 · Cited by 150 · cited 2×
“that applies functional electrical stimulation [16]–[23].”
BackgroundDeep Brain Stimulation and Tremor
Lyons, K. E., & Pahwa, R. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2008.01.004 · Cited by 143 · cited 1×
“In cases of severe tremor, surgical interventions, such as deep brain stimulator implantation and stereotactic thalamotomy [7], [8], have been performed.”
BackgroundTremor disorders. Diagnosis and management.
Anouti, A., & Koller, W. C. (1995) · PubMed Central · Cited by 139
Diagnosis and Treatment of Common Forms of Tremor
Puschmann, A., & Wszolek, Z. (2011) · Seminars in Neurology · doi:10.1055/s-0031-1271312 · Cited by 138
Neurological Tremor: Sensors, Signal Processing and Emerging Applications
Grimaldi, G., & Manto, M. (2010) · Sensors · doi:10.3390/s100201399 · Cited by 138
Electrical stimulation for the suppression of pathological tremor
Popović Maneski, L., Jorgovanović, N., Ilić, V., Došen, S., Keller, T., Popović, M. B., & Popović, D. B. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0803-6 · Cited by 129
Online tremor suppression using electromyography and low-level electrical stimulation
Dosen, S., Muceli, S., Dideriksen, J. L., Romero, J. P., Rocon, E., Pons, J., & Farina, D. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2328296 · Cited by 120
Estimation of physiological tremor from accelerometers for real-time applications
Veluvolu, K. C., & Ang, W. T. (2011) · Sensors · doi:10.3390/s110303020 · Cited by 117 · cited 1×
“Other WFLC derivatives [56], [57] use multiple frequency bands to increase the estimation accuracy.”
BackgroundThe Clinical Evaluation of Parkinson’s Tremor
Zach, H., Dirkx, M., Bloem, B. R., & Helmich, R. C. (2015) · Journal of Parkinson's Disease · doi:10.3233/jpd-150650 · Cited by 113 · cited 1×
“This finding is supported by a recent study showing that position change can reduce resting tremor amplitude [58].”
ResultAn adaptive estimation of periodic signals using a Fourier linear combiner
Vaz, C., Kong, X., & Thakor, N. (1994) · IEEE Transactions on Signal Processing · doi:10.1109/78.258116 · Cited by 108 · cited 2×
“The least mean squares algorithm was incorporated to update the parameters, without involving a large computational workload [40], and it was able to surpass any common filter with its zero-phase feature [41].”
BackgroundMethodFrequency spectrum analysis of wrist motion for activities of daily living
Mann, K. A., Wernere, F. W., & Palmer, A. K. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070219 · Cited by 107
Real-Time Estimation of Pathological Tremor Parameters from Gyroscope Data
Gallego, J., Rocon, E., Roa, J. O., Moreno, J., & Pons, J. L. (2010) · Sensors · doi:10.3390/s100302129 · Cited by 107
Design and Characterization of a Small-Scale Magnetorheological Damper for Tremor Suppression
Case, D., Taheri, B., & Richer, E. (2013) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2011.2151204 · Cited by 98
Zhang, D., Poignet, P., Widjaja, F., & Tech Ang, W. (2011) · Control Engineering Practice · doi:10.1016/j.conengprac.2010.08.009 · Cited by 88
Rehabilitation Robotics: a Wearable Exo-Skeleton for Tremor Assessment and Suppression
Rocon, E., Ruiz, A. F., Pons, J. L., Belda-Lois, J. M., & Sanchez-Lacuesta, J. J. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570451 · Cited by 87
Bandlimited Multiple Fourier Linear Combiner for Real-time Tremor Compensation
Veluvolu, K. C., Tan, U. X., Latt, W. T., Shee, C. Y., & Ang, W. T. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352922 · Cited by 83
Adaptive Fourier modeling for quantification of tremor
Riviere, C. N., Reich, S. G., & Thakor, N. V. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(97)02263-2 · Cited by 83 · cited 2×
“studies [21], [30], [42]–[44], [51] the WFLC was used to estimate only the fundamental frequency.”
MethodA neuroprosthesis for tremor management through the control of muscle co-contraction
Gallego, J. Á., Rocon, E., Belda-Lois, J. M., & Pons, J. L. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-36 · Cited by 81 · cited 1×
“studies [21], [30], [42]–[44], [51] the WFLC was used to estimate only the fundamental frequency.”
Method(1987) · PubMed · Cited by 75
Loureiro, R. C. V., Belda-Lois, J. M., Lima, E. R., Pons, J. L., Sanchez-Lacuesta, J. J., & Harwin, W. S. (2005) · 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005. · doi:10.1109/icorr.2005.1501065 · Cited by 70 · cited 3×
“viable alternative solution for tremor management [10]–[25].”
MethodA longitudinal study of tremor frequencies in Parkinson’s disease and essential tremor
Hellwig, B., Mund, P., Schelter, B., Guschlbauer, B., Timmer, J., & Lücking, C. H. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.11.002 · Cited by 65 · cited 1×
“Several studies [26]–[35] have been conducted to characterize the mechanical and electrical features of tremor.”
BackgroundRobust Controller for Tremor Suppression at Musculoskeletal Level in Human Wrist
Taheri, B., Case, D., & Richer, E. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2295034 · Cited by 64
Linear and nonlinear tremor acceleration characteristics in patients with Parkinson's disease
Meigal, A. Y., Rissanen, S. M., Tarvainen, M. P., Georgiadis, S. D., Karjalainen, P. A., Airaksinen, O., & Kankaanpää, M. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/3/395 · Cited by 63
Pathological Tremor and Voluntary Motion Modeling and Online Estimation for Active Compensation
Bo, A. P. L., Poignet, P., & Geny, C. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2091283 · Cited by 53
Stereotactic thalamotomy in tremor‐dominant Parkinson's disease: An H215O PET motor activation study
Boecker, H., Wills, A. J., Ceballos‐Baumann, A., Samuel, M., Thomas, D. G. T., Marsden, C. D., & Brooks, D. J. (1997) · Annals of Neurology · doi:10.1002/ana.410410118 · Cited by 52
Bilateral tremor relations in Parkinson's disease: Effects of mechanical coupling and medication
Morrison, S., Kerr, G., & Silburn, P. A. (2007) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2007.09.004 · Cited by 50
Zhou, Y., Naish, M. D., Jenkins, M. E., & Trejos, A. L. (2017) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2016.12.009 · Cited by 46 · cited 2×
“viable alternative solution for tremor management [10]–[25].”
MethodSelf-citationAdaptive sliding bandlimited multiple fourier linear combiner for estimation of pathological tremor
Wang, S., Gao, Y., Zhao, J., & Cai, H. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.10.004 · Cited by 42
A soft wearable robot for tremor assessment and suppression
Gallego, J. A., Rocon, E., Ibanez, J., Dideriksen, J. L., Koutsou, A. D., Paradiso, R., Popovic, M. B., Belda-Lois, J. M., Gianfelici, F., Farina, D., et al. (2011) · 2011 IEEE International Conference on Robotics and Automation · doi:10.1109/icra.2011.5979639 · Cited by 38
Tatinati, S., Veluvolu, K. C., Hong, S.-M., Latt, W. T., & Ang, W. T. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2271737 · Cited by 38
Pellegrini, B., Faes, L., Nollo, G., & Schena, F. F. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.04.025 · Cited by 37
Adaptive signal processing for adaptive control
Widrow, B. C., & Walach, E. (2005) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.1984.1172527 · Cited by 35
Reciprocal EMG Controlled FES for Pathological Tremor Suppression of Forearm
Zhang, D., & Ang, W. T. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4353416 · Cited by 34
The measurement and analysis of parkinsonian hand tremor
Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2016) · 2016 IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI) · doi:10.1109/bhi.2016.7455922 · Cited by 33 · cited 1×
“gradient search method [45]–[47].”
Self-citationOn-Off Tremor Suppression Orthosis with Electromagnetic Brake
Herrnstadt, G., & Menon, C. (2013) · International Journal of Mechanical Engineering and Mechatronics · doi:10.11159/ijmem.2013.002 · Cited by 32
Kazi, S., As’arry, A., Zain, M. Z. M., Mailah, M., & Hussein, M. (2010) · WSEAS TRANSACTIONS ON SYSTEMS AND CONTROL · Cited by 32
Saxena, A., & Patel, R. V. (2013) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2013.6696969 · Cited by 31
FES-controlled co-contraction strategies for pathological tremor compensation
Bo, A. P. L., Poignet, P., Zhang, D., & Ang, W. T. (2009) · 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2009.5354397 · Cited by 30
THE EFFECT OF MECHANICAL IMPEDANCE ON ABNORMAL INTENTION TREMOR
Adelstein, B. D., & Rosen, M. J. (1981) · Bioengineering · doi:10.1016/b978-0-08-027207-8.50047-3 · Cited by 28 · cited 1×
“Since Rosen and Aldenstein [9] first demonstrated that pathological tremor can be suppressed selectively, several research groups have proposed WTSDs as a potentially”
BackgroundOnline pathological tremor characterization using extended Kalman filtering
Bo, A. P. L., Poignet, P., Widjaja, F., & Ang, W. T. (2008) · 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2008.4649516 · Cited by 23
Widjaja, F., Shee, C. Y., Latt, W. T., Au, W. L., Poignet, P., & Ang, W. T. (2008) · 2008 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2008.4543706 · Cited by 23
Hybrid learning control for improving suppression of hand tremor
As’arry, A., Zain, M. Z. M., Mailah, M., & Hussein, M. (2013) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411913494325 · Cited by 19
Lambrecht, S., Gallego, J. A., Rocon, E., & Pons, J. L. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00221 · Cited by 16
Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2016) · 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7592069 · Cited by 16
Self-citationTaheri, B., Case, D., & Richer, E. (2013) · Volume 2: Control, Monitoring, and Energy Harvesting of Vibratory Systems; Cooperative and Networked Control; Delay Systems; Dynamical Modeling and Diagnostics in Biomedical Systems; Estimation and Id of Energy Systems; Fault Detection; Flow and Thermal Systems; Haptics and Hand Motion; Human Assistive Systems and Wearable Robots; Instrumentation and Characterization in Bio-Systems; Intelligent Transportation Systems; Linear Systems and Robust Control; Marine Vehicles; Nonholonomic Systems · doi:10.1115/dscc2013-3954 · Cited by 11
Prediction of pathological tremor using adaptive multiple oscillators linear combiner
Xiao, F., Gao, Y., Wang, S., & Zhao, J. (2016) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.01.006 · Cited by 11
Active vibration control of essential tremor.
Sitaram, S., Lavu, C., & Gupta, A. (2009) · Cited by 8
Active vibration control of essential tremor.
Lavu, S. S. C. (2011) · Huskie Commons (Northern Illinois University) · Cited by 4
Spectral and Higher-Order-Spectral Analysis of Tremor Time Series
Klatt, J. (2014) · Clinical and Experimental Pharmacology · doi:10.4172/2161-1459.1000149 · Cited by 3
Tracking Tremor Frequency in Spike Trains Using the Extended Kalman Filter
Kim, S., & McNames, J. (2005) · 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference · doi:10.1109/iembs.2005.1616265
Research works printed but not linked: 5
- gonzález, 1995, A new approach to suppressing abnormal tremor through signal equalization, Proc RESNA Annu Conf, 707
- rocon, 2005, Estimation of biomechanical characteristics of tremorous movements based on gyroscopes, Virtual Reality and Assistive Technology, 138
- elble, 1990, Tremor, 54
- pons, 2012, A wearable neuroprosthesis for the suppression of pathological tremor, IEEE Life Sci Newslett
- 2012, Android SDK
Cited by
Smartwatch for the analysis of rest tremor in patients with Parkinson's disease
Blanco, R. L., Velasco, M. A., Méndez-Guerrero, A., Romero, J. P., del Castillo, M. D., Serrano, J. I., Rocón, E., & Benito‐León, J. (2019) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2019.04.011 · Cited by 97
Design and Preliminary Performance Assessment of a Wearable Tremor Suppression Glove
Zhou, Y., Ibrahim, A. H., Hardy, K. G., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3080622 · Cited by 37
Self-citationReal-Time Voluntary Motion Prediction and Parkinson’s Tremor Reduction Using Deep Neural Networks
Ibrahim, A. H., Zhou, Y., Jenkins, M. E., Trejos, A. L., & Naish, M. D. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3097007 · Cited by 34
Self-citationMenguc, E. C., cnar, S., Xiang, M., & P. Mandic, D. (2021) · IEEE Signal Processing Letters · doi:10.1109/lsp.2021.3097279 · Cited by 25
Peripherical Electrical Stimulation for Parkinsonian Tremor: A Systematic Review
Meng, L., Jin, M., Zhu, X., & Ming, D. (2022) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2022.795454 · Cited by 30
Metadata
- Authors
- Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L.
- Affiliations
- Western University (CA)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2018-09
- Volume
- 26
- Issue
- 9
- Pages
- 1823-1834
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2883932938
- Cited by
- 42
- References
- 72
- Citations by year
- 2026: 2 · 2025: 6 · 2024: 5 · 2023: 5 · 2022: 9 · 2021: 7 · 2020: 6 · 2019: 2
- FWCI
- 1.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- Scholarship@Western (Western University) (submittedVersion)
- Funders
- Western University
- Natural Sciences and Engineering Research Council of Canada (RGPIN-2014-03815)
- Ontario Ministry of Economic Development, Trade and Employment and the Ontario Ministry of Research and Innovation through the Early Researcher Award
- Peter C. Maurice Research Fellowship in Biomedical Engineering
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Effects of Vibration on Health
- Keywords
- finger tremor, Kalman filter
- MeSH terms
- Wearable Electronic Devices, Aged, Aged, 80 and over, Algorithms, Biomechanical Phenomena, Elbow, Female, Fingers, Fourier Analysis, Hand, Humans, Male, Middle Aged, Tremor, Wrist, Reproducibility of Results, Parkinsonian Disorders
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.