CoChat

The Association of High Resolution Cervical Auscultation Signal Features With Hyoid Bone Displacement During Swallowing

Open access
He, Qifan, Perera, Subashan, Khalifa, Yassin, Zhang, Zhenwei, Mahoney, Amanda S., Sabry, Aliaa, Donohue, Cara, Coyle, James L., Sejdic, Ervin · 2019 · IEEE Transactions on Neural Systems and Rehabilitation Engineering
Cited by 39

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Recent publications have suggested that high-resolution cervical auscultation (HRCA) signals may provide an alternative non-invasive option for swallowing assessment. However, the relationship between hyoid bone displacement, a key component to safe swallowing, and HRCA signals is not thoroughly understood. Therefore, in this work we investigated the hypothesis that a strong relationship exists between hyoid displacement and HRCA signals. Videofuoroscopy data was collected for 129 swallows, simultaneously with vibratory/acoustic signals. Horizontal, vertical and hypotenuse displacements of the hyoid bone were measured through manual expert analysis of videofluoroscopy images. Our results showed that the vertical displacement of both the anterior and posterior landmarks of the hyoid bone was strongly associated with the Lempel-Ziv complexity of superior-inferior and anterior-posterior vibrations from HRCA signals. Horizontal and hypotenuse displacements of the posterior aspect of the hyoid bone were strongly associated with the standard deviation of swallowing sounds. Medial-Lateral vibrations and patient characteristics such as age, sex, and history of stroke were not significantly associated with the hyoid bone displacement. The results imply that some vibratory/acoustic features extracted from HRCA recordings can provide information about the magnitude and direction of hyoid bone displacement. These results provide additional support for using HRCA as a non-invasive tool to assess physiological aspects of swallowing such as the hyoid bone displacement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2019.2935302

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Research works printed but not linked: 36

  1. 10.1007/s00455-007-9135-y · DOI · Paper page
  2. 10.1007/s00455-009-9224-1 · DOI
  3. 10.1016/S0165-0270(00)00356-3 · DOI · Paper page
  4. hu, 2006, Analysis of biomedical signals by the Lempel-Ziv complexity: The effect of finite data size, IEEE Trans Biomed Eng, 53, 2606, 10.1109/TBME.2006.883825 · DOI · Paper page
  5. 10.1109/TBME.2006.883696 · DOI · Paper page
  6. sejdi?, 2009, A procedure for denoising dual-axis swallowing accelerometry signals, Physiolog Meas, 31, 1n
  7. 10.1044/2014_JSLHR-S-13-0152 · DOI · Paper page
  8. 10.1016/0016-5085(89)90391-0 · DOI · Paper page
  9. 10.1115/IMECE2016-66133 · DOI
  10. steele, 2007, Dysphagia service delivery by speech-language pathologists in Canada: Results of a national survey, Canadian Journal of Speech- Language Pathology and Audiology, 31, 166
  11. 10.1007/s00455-002-0064-5 · DOI · Paper page
  12. 10.1007/s00455-006-9031-x · DOI
  13. 10.1007/BF02638588 · doi:10.1007/bf02638588
  14. 10.1109/MSP.2018.2875863 · DOI
  15. 10.1109/TNSRE.2016.2577882 · DOI · Paper page
  16. 10.1109/TBME.2015.2431999 · DOI
  17. 10.1186/1743-0003-3-14 · DOI · Paper page
  18. 10.1088/0967-3334/29/9/008 · DOI
  19. 10.1016/0141-5425(91)90018-3 · DOI
  20. 10.1186/1756-0500-3-269 · DOI · Paper page
  21. 10.1007/s10439-009-9874-z · DOI
  22. 10.1007/s00455-007-9084-5 · DOI
  23. 10.1016/j.pmrj.2011.09.006 · DOI
  24. 10.1371/journal.pone.0033464 · DOI
  25. 10.1007/s00455-002-0094-z · DOI
  26. 10.1038/ncpgasthep1153 · DOI
  27. 10.1097/00020840-199706000-00001 · DOI
  28. 10.1097/00020840-199812000-00008 · DOI · Paper page
  29. 10.1097/01.COT.0000358150.50765.f2 · doi:10.1097/01.cot.0000358150.50765.f2
  30. 10.1177/0194599814549156 · DOI · Paper page
  31. 10.1016/S1350-4533(00)00047-3 · DOI
  32. 10.1088/0967-3334/31/6/008 · DOI
  33. 10.1109/THMS.2015.2408615 · DOI
  34. rebrion, 2018, High-resolution cervical auscultation signal features reflect vertical and horizontal displacements of the hyoid bone during swallowing, IEEE J Transl Eng Health Med, 7
  35. 10.1016/j.jelekin.2006.09.011 · DOI
  36. 10.1044/1058-0360(2007/018) · doi:10.1044/1058-0360(2007/018 · Paper page

Cited by

See all 39

Metadata

Authors
He, Q., Perera, S., Khalifa, Y., Zhang, Z., Mahoney, A. S., Sabry, A., Donohue, C., Coyle, J. L., & Sejdic, E.
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2019-09
Volume
27
Issue
9
Pages
1810-1816
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2914392558
Cited by
39
References
4
FWCI
7.78
Type
journal article
Language
en
Open access
green
Funders
Eunice Kennedy Shriver National Institute of Child Health and Human Development (R01HD092239, R01HD074819)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Association of High Resolution Cervical Auscultation Signal Features With Hyoid Bone Displacement During Swallowing. https://app.cochat.ai/papers/10.1109/tnsre.2019.2935302
The paper
He, Q., Perera, S., Khalifa, Y., Zhang, Z., Mahoney, A. S., Sabry, A., Donohue, C., Coyle, J. L., & Sejdic, E. (2019). The Association of High Resolution Cervical Auscultation Signal Features With Hyoid Bone Displacement During Swallowing. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2019.2935302

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.