The effects of head movement on dual-axis cervical accelerometry signals
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Head motions can severely affect dual-axis cervical acceloremetry signals. A complete understanding of the effects of head motion is required before a robust accelerometry-based medical device can be developed. In this paper, we examine the spectral characteristics of dual-axis cervical accelerometry signals in the absence of swallowing but in the presence of head motions. FINDINGS: Data from 50 healthy adults were collected while participants performed five different head motions. Three different spectral features were extracted from each recording: peak frequency, spectral centroid and bandwidth. Statistical analyses showed that peak frequencies are independent of the type of head motion, participant gender and age. However, spectral centroids are statistically different between the anterior-posterior (A-P) and superior-inferior (S-I) directions and between different motion. Additionally, statistically different bandwidths are observed for head tilts down and back between the A-P and the S-I directions. CONCLUSIONS: These differences indicate that head motions induce additional non-dominant spectral components in dual-axis cervical recordings. The results presented here suggest that head motion ought to be considered in the development of medical devices based on dual-axis cervical accelerometery signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sejdic, E., Steele, C. M., & Chau, T. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2010504 · Cited by 73 · cited 3×
“However, recent studies have shown that dual-axis accelerometers yield more information and enhance analysis capabilities [7,8], likely due to the two-dimensional movement of the hyoid and the larynx during swallowing [[9]].”
BackgroundSelf-citation
Research works printed but not linked: 16
- Miller AJ: The neuroscientific principles of swallowing and dysphagia. 1999, San Diego, USA: Singular Publishing Group
- Logemann JA: Evaluation and treatment of swallowing disorders. 1998, Austin, Texas, USA: PRO-ED, second
- Steele C, Allen C, Barker J, Buen P, French R, Fedorak A, Day S, Lapointe J, Lewis L, MacKnight C, McNeil S, Valentine J, Walsh L: Dysphagia service delivery by speech-language pathologists in Canada: results of a national survey. Canadian Journal of Speech-Language Pathology and Audiology. 2007, 31 (4): 166-177.
- Ramsey DJC, Smithard DG, Kalra L: Can Pulse Oximetry or a Bedside Swallowing Assessment Be Used to Detect Aspiration After Stroke?. Stroke. 2006, 37 (12): 2984-2988. 10.1161/01.STR.0000248758.32627.3b. · DOI
- Reddy NP, Costarella BR, Grotz RC, Canilang EP: Biomechanical measurements to characterize the oral phase of dysphagia. IEEE Transactions on Biomedical Engineering. 1990, 37 (4): 392-397. 10.1109/10.52346. · DOI · Paper page
- Chau T, Chau D, Casas M, Berall G, Kenny DJ: Investigating the stationarity of paediatric aspiration signals. IEEE Transactions on Neural Systems and Rehabilitation Engineering. 2005, 13: 99-105. 10.1109/TNSRE.2004.841384. · DOI · Paper page
- Lee J, Steele CM, Chau T: Time and time-frequency characterization of dual-axis swallowing accelerometry signals. Physiological Measurement. 2008, 29 (9): 1105-1120. 10.1088/0967-3334/29/9/008. · DOI
- Sejdić E, Komisar V, Steele CM, Chau T: Baseline characteristics of dual-axis swallowing accelerometry signals. Annals of Biomedical Engineering. 2010, 38 (3): 1048-1059. 10.1007/s10439-009-9874-z. · DOI
- Donoho DL: De-noising by soft-thresholding. IEEE Transactions on Information Theory. 1995, 41 (3): 613-627. 10.1109/18.382009. · DOI · Paper page
- Sejdić E, Steele CM, Chau T: A procedure for denoising dual-axis swallowing accelerometry signals. Physiological Measurement. 2010, 31: N1-N9. 10.1088/0967-3334/31/1/N01. · DOI · Paper page
- Merletti R, Gulisashvili A, Lo Conte LR: Estimation of shape characteristics of surface muscle signal spectra from time domain data. IEEE Transactions on Biomedical Engineering. 1995, 42 (8): 769-776. 10.1109/10.398637. · doi:10.1109/10.398637
- Li SZ: Content-based classification and retrieval of audio using the nearest feature line method. IEEE Transactions on Speech and Audio Processing. 2000, 8 (5): 619-625. 10.1109/89.861383. · DOI
- Kruskal WH, Wallis WA: Use of ranks in one-criterion analysis of variance. Journal of the American Statistical Association. 1952, 47 (260): 583-621. 10.2307/2280779. · DOI · Paper page
- Mann HB, Whitney DR: On a Test of Whether one of Two Random Variables is Stochastically Larger than the Other. The Annals of Mathematical Statistics. 1947, 18: 50-60. 10.1214/aoms/1177730491. · DOI · Paper page
- Hung D, Sejdić E, Steele CM, Chau T: Extraction of average neck flexion angle during swallowing in neutral and chin-tuck positions. BioMedical Engineering OnLine. 2009, 8: 10.1186/1475-925X-8-25. 25-1-9 · doi:10.1186/1475-925x-8-25
- Liang H, Lin QH, Chen JDZ: Application of the empirical mode decomposition to the analysis of esophageal manometric data in gastroesophageal reflux disease. IEEE Transactions on Biomedical Engineering. 2005, 52 (10): 1692-1701. 10.1109/TBME.2005.855719. · DOI · Paper page
Cited by
Khalifa, Y., Donohue, C., Coyle, J. L., & Sejdic, E. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3000057 · Cited by 49
Self-citationDonohue, C., Khalifa, Y., Perera, S., Sejdić, E., & Coyle, J. L. (2021) · Dysphagia · doi:10.1007/s00455-020-10177-0 · Cited by 41
Self-citationQuantitative classification of pediatric swallowing through accelerometry
Celeste, M., Azadeh, K., Sejdić, E., Berall, G., & Chau, T. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-34 · Cited by 37
Self-citationSilent Aspiration Detection in High Resolution Cervical Auscultations
Yu, C., Khalifa, Y., & Sejdic, E. (2019) · 2019 IEEE EMBS International Conference on Biomedical & Health Informatics (BHI) · doi:10.1109/bhi.2019.8834576 · Cited by 22
Metadata
- Authors
- Sejdić, E., Steele, C. M., & Chau, T.
- Venue
- BMC Research Notes
- Published
- 2010-10-26
- Volume
- 3
- Issue
- 1
- Pages
- 269-269
- ISSN
- 1756-0500 (ISSN-L)
- OpenAlex
- W2065784508
- Cited by
- 32
- References
- 1
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- gold
- Licence
- creativecommons.org/licenses/by/2.0 (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The effects of head movement on dual-axis cervical accelerometry signals. https://app.cochat.ai/papers/10.1186/1756-0500-3-269
- The paper
- Sejdić, E., Steele, C. M., & Chau, T. (2010). The effects of head movement on dual-axis cervical accelerometry signals. BMC Research Notes. https://doi.org/10.1186/1756-0500-3-269
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.