Optimal Electric Stimulus Amplitude Improves the Selectivity Between Responses of ON Versus OFF Types of Retinal Ganglion Cells
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Outer retinal degenerative diseases destroy photoreceptors primarily in the retina, resulting in a profound vision loss. Fortunately, surviving retinal neurons can be electrically stimulated using retinal prostheses to re-transmit visual information. Although retinal prostheses are promising for sight restoration, the best performance is still sub-optimal. For the enhanced performance, it is critical to optimize stimulation parameters. This study explored how stimulus charge and current amplitude alters responses of retinal ganglion cells (RGCs). From the isolated mouse retina, spiking activities of alpha ON, OFF sustained, and OFF transient RGCs were recorded in response to epiretinally-delivered cathodal current pulses ranging from -10 to [Formula: see text]. We have found that intermediate current amplitudes (-30 and [Formula: see text]) maximize the response ratio of ON over OFF types. Also, the ON/OFF response ratio was always bigger for 10-ms-long than 5-ms-long stimuli. It was because, by the longer pulses, ON RGC responses were always significantly enhanced ( ) while OFF RGC responses were minimally changed ( ). Given the earlier work reporting electrically-elicited responses are more natural in ON than OFF RGCs, the present study suggests effect strategies of more selective activation of ON RGCs for improved efficacy of retinal implant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hartong, D. T., Berson, E. L., & Dryja, T. P. (2006) · The Lancet · doi:10.1016/s0140-6736(06)69740-7 · Cited by 2,924
The functional diversity of retinal ganglion cells in the mouse
Baden, T., Berens, P., Franke, K., Román Rosón, M., Bethge, M., & Euler, T. (2016) · Nature · doi:10.1038/nature16468 · Cited by 999 · cited 2×
“each of which conveys specific features of visual information to the brain in parallel [22], [23].”
BackgroundVisual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856 · cited 1×
“Multiple groups have demonstrated visual percepts can be artificially elicited [7]–[14], and some of those groups succeeded in the commercialization of microelectronic prosthetic devices: Argus II of Second Sight, Alpha IMS of Retinal Implant (but discontinues business in March 2019), and IRIS of Pixium Vision.”
BackgroundSubretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819 · cited 2×
“Although earlier clinical trials of the commerciallyavailable devices showed a somewhat useful level of restored vision [10]–[12], the best visual acuity achieved so far, 20/546, has reached neither the theoretical maximum visual acuity, 20/250 [15] nor the normal vision, 20/20.”
BackgroundRizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478
Artificial vision with wirelessly powered subretinal electronic implant alpha-IMS
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Braun, A., Bruckmann, A., Gekeler, F., Greppmaier, U., Hipp, S., Hörtdörfer, G., Kernstock, C., et al. (2013) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2013.0077 · Cited by 473 · cited 1×
“quite close to the one used by the majority of retinal implant users during clinical trials [10], [11], [15], [26].”
BackgroundSubretinal visual implant alpha IMS - clinical trial interim report
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Chee, C. K., Cottriall, C. L., Gekeler, F., Groppe, M., Jackson, T. L., MacLaren, R. E., Koitschev, A., et al. (2015) · Vision Research · doi:10.1016/j.visres.2015.03.001 · Cited by 387
da Cruz, L., Coley, B. F., Dorn, J., Merlini, F., Filley, E., Christopher, P., Chen, F. K., Wuyyuru, V., Sahel, J., Stanga, P., et al. (2013) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-301525 · Cited by 359 · cited 1×
“Although earlier clinical trials of the commerciallyavailable devices showed a somewhat useful level of restored vision [10]–[12], the best visual acuity achieved so far, 20/546, has reached neither the theoretical maximum visual acuity, 20/250 [15] nor the normal vision, 20/20.”
BackgroundMORPHOMETRIC ANALYSIS OF THE MACULA IN EYES WITH DISCIFORM AGE-RELATED MACULAR DEGENERATION
KIM, S. Y., SADDA, S., PEARLMAN, J., HUMAYUN, M. S., de JUAN, E., MELIA, B. M., & GREEN, W. R. (2002) · Retina · doi:10.1097/00006982-200208000-00012 · Cited by 158 · cited 1×
“those diseases [3]–[5], leaving a possibility of sight restoration.”
BackgroundImproving the spatial resolution of epiretinal implants by increasing stimulus pulse duration
Weitz, A. C., Nanduri, D., Behrend, M. R., Gonzalez-Calle, A., Greenberg, R. J., Humayun, M. S., Chow, R. H., & Weiland, J. D. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aac4877 · Cited by 154 · cited 4×
“activate RGCs [34] demonstrated more focal stimulation for improved spatial resolution of retinal prostheses [18].”
BackgroundInfluential
Cited by
Computational challenges and opportunities for a bi-directional artificial retina
Shah, N. P., & Chichilnisky, E. J. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/aba8b1 · Cited by 39
“This observation is in contrast to previous efforts to optimize the selectivity of activation, i.e. activating one or a few target cells while not activating non-target cells (see section 3 above) (Fried et al 2006, Wong et al 2009, Freeman et al 2010, Jepson et al 2013, 2014b, Lee and Im 2019).”
ResultAdvances in Neural Recording and Stimulation Integrated Circuits
Li, J., Liu, X., Mao, W., Chen, T., & Yu, H. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.663204 · Cited by 21
Human-in-the-loop optimization of visual prosthetic stimulation
Fauvel, T., & Chalk, M. (2021) · doi:10.1101/2021.11.24.469867 · Cited by 15
Human-in-the-loop optimization of visual prosthetic stimulation
Fauvel, T., & Chalk, M. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac7615 · Cited by 15
“Another line of research seeks to optimize the stimulation protocol so as to mimic the activity of retinal neurons under natural conditions (Nirenberg and Pandarinath 2012, Twyford et al 2014, Guo et al 2018, Lee and Im 2019, Shah et al 2019).”
Influential
Metadata
- Authors
- Lee, J.-I., & Im, M.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2019-10
- Volume
- 27
- Issue
- 10
- Pages
- 2015-2024
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2971703557
- Cited by
- 39
- References
- 14
- FWCI
- 2.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal Electric Stimulus Amplitude Improves the Selectivity Between Responses of ON Versus OFF Types of Retinal Ganglion Cells. https://app.cochat.ai/papers/10.1109/tnsre.2019.2939012
- The paper
- Lee, J.-I., & Im, M. (2019). Optimal Electric Stimulus Amplitude Improves the Selectivity Between Responses of ON Versus OFF Types of Retinal Ganglion Cells. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2019.2939012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.