The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Latent Palmprint Matching
Abstract
The evidential value of palmprints in forensic applications is clear as about 30 percent of the latents recovered from crime scenes are from palms. While biometric systems for palmprint-based personal authentication in access control type of applications have been developed, they mostly deal with low-resolution (about 100 ppi) palmprints and only perform full-to-full palmprint matching. We propose a latent-to-full palmprint matching system that is needed in forensic applications. Our system deals with palmprints captured at 500 ppi (the current standard in forensic applications) or higher resolution and uses minutiae as features to be compatible with the methodology used by latent experts. Latent palmprint matching is a challenging problem because latent prints lifted at crime scenes are of poor image quality, cover only a small area of the palm, and have a complex background. Other difficulties include a large number of minutiae in full prints (about 10 times as many as fingerprints), and the presence of many creases in latents and full prints. A robust algorithm to reliably estimate the local ridge direction and frequency in palmprints is developed. This facilitates the extraction of ridge and minutiae features even in poor quality palmprints. A fixed-length minutia descriptor, MinutiaCode, is utilized to capture distinctive information around each minutia and an alignment-based minutiae matching algorithm is used to match two palmprints. Two sets of partial palmprints (150 live-scan partial palmprints and 100 latent palmprints) are matched to a background database of 10,200 full palmprints to test the proposed system. Despite the inherent difficulty of latent-to-full palmprint matching, rank-1 recognition rates of 78.7 and 69 percent, respectively, were achieved in searching live-scan partial palmprints and latent palmprints against the background database.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Distinctive Image Features from Scale-Invariant Keypoints
Lowe, D. G. (2004) · International Journal of Computer Vision · doi:10.1023/b:visi.0000029664.99615.94 · Cited by 55,589
Fischler, M. A., & Bolles, R. C. (1981) · Communications of the ACM · doi:10.1145/358669.358692 · Cited by 25,893
Atherosclerosis--an inflammatory disease
Ross, R. (1999) · New England Journal of Medicine · doi:10.1056/nejm199901143400207 · Cited by 21,725
Chan, T. F., & Vese, L. A. (2001) · IEEE Transactions on Image Processing · doi:10.1109/83.902291 · Cited by 10,304
Hulley, S. (1998) · JAMA · doi:10.1001/jama.280.7.605 · Cited by 6,216
Adaptive histogram equalization and its variations
Pizer, S. M., Amburn, E. P., Austin, J. D., Cromartie, R., Geselowitz, A., Greer, T., ter Haar Romeny, B., Zimmerman, J. B., & Zuiderveld, K. (1987) · Computer Vision, Graphics, and Image Processing · doi:10.1016/s0734-189x(87)80186-x · Cited by 4,012
Daugman, J. G. (1985) · Journal of the Optical Society of America A · doi:10.1364/josaa.2.001160 · Cited by 3,219
The Protective Effects of Estrogen on the Cardiovascular System
Mendelsohn, M. E., & Karas, R. H. (1999) · New England Journal of Medicine · doi:10.1056/nejm199906103402306 · Cited by 3,103
Handbook of Fingerprint Recognition
(2003) · Springer Professional Computing · doi:10.1007/b97303 · Cited by 2,820
Interleukin-6 and the acute phase response
Heinrich, P. C., Castell, J. V., & Andus, T. (1990) · Biochemical Journal · doi:10.1042/bj2650621 · Cited by 2,734
Yudkin, J. S., Stehouwer, C. D. A., Emeis, J. J., & Coppack, S. W. (1999) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.19.4.972 · Cited by 2,465
Fingerprint image enhancement: algorithm and performance evaluation
Hong, L., Wan, Y., & Jain, A. (1998) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.709565 · Cited by 2,097
Self-citationDirect Proinflammatory Effect of C-Reactive Protein on Human Endothelial Cells
Pasceri, V., Willerson, J. T., & Yeh, E. T. H. (2000) · Circulation · doi:10.1161/01.cir.102.18.2165 · Cited by 1,940
Ridker, P. M., Buring, J. E., Shih, J., Matias, M., & Hennekens, C. H. (1998) · Circulation · doi:10.1161/01.cir.98.8.731 · Cited by 1,642
Ridker, P. M., Rifai, N., Clearfield, M., Downs, J. R., Weis, S. E., Miles, J. S., & Gotto, A. M. (2001) · New England Journal of Medicine · doi:10.1056/nejm200106283442601 · Cited by 1,557
Online palmprint identification
Zhang, D., Kong, W.-K., You, J., & Wong, M. (2003) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2003.1227981 · Cited by 1,506
On-line fingerprint verification
Jain, A., Hong, L., & Bolle, R. (1997) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.587996 · Cited by 1,316
Self-citationThe Resonant Retina: Exploiting Vibration Noise to Optimally Detect Edges in an Image
Zhang, D. D., Kong, W.-K., You, J., & Wong, M. (2003) · IEEE Transactions on Pattern Analysis and Machine Intelligence · Cited by 901
Zwaka, T. P., Hombach, V., & Torzewski, J. (2001) · Circulation · doi:10.1161/01.cir.103.9.1194 · Cited by 845
C-reactive protein induces human peripheral blood monocytes to synthesize tissue factor
Cermak, J., Key, N., Bach, R., Balla, J., Jacob, H., & Vercellotti, G. (1993) · Blood · doi:10.1182/blood.v82.2.513.513 · Cited by 839
Tracy, R. P., Lemaitre, R. N., Psaty, B. M., Ives, D. G., Evans, R. W., Cushman, M., Meilahn, E. N., & Kuller, L. H. (1997) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.17.6.1121 · Cited by 836
Pasceri, V., Chang, J., Willerson, J. T., & Yeh, E. T. H. (2001) · Circulation · doi:10.1161/01.cir.103.21.2531 · Cited by 831
Jialal, I., Stein, D., Balis, D., Grundy, S. M., Adams-Huet, B., & Devaraj, S. (2001) · Circulation · doi:10.1161/01.cir.103.15.1933 · Cited by 730
Cushman, M., Legault, C., Barrett-Connor, E., Stefanick, M. L., Kessler, C., Judd, H. L., Sakkinen, P. A., & Tracy, R. P. (1999) · Circulation · doi:10.1161/01.cir.100.7.717 · Cited by 660
Generation of C-Reactive Protein and Complement Components in Atherosclerotic Plaques
Yasojima, K., Schwab, C., McGeer, E. G., & McGeer, P. L. (2001) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)64051-5 · Cited by 564
Finger Prints, Palms and Soles: an Introduction to Dermatoglyphics.
(1944) · Archives of Pediatrics & Adolescent Medicine · doi:10.1001/archpedi.1944.02020110063021 · Cited by 541
Fingerprint minutiae matching based on the local and global structures
Jiang, X., & Yau, W.-Y. (2002) · Proceedings 15th International Conference on Pattern Recognition. ICPR-2000 · doi:10.1109/icpr.2000.906252 · Cited by 478
Ordinal Palmprint Represention for Personal Identification
Sun, Z., Tan, T., Wang, Y., & Li, S. (2005) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.2005.267 · Cited by 469
Sparrow, C. P., Burton, C. A., Hernandez, M., Mundt, S., Hassing, H., Patel, S., Rosa, R., Hermanowski-Vosatka, A., Wang, P.-R., Zhang, D., et al. (2001) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.21.1.115 · Cited by 413
Weber, C., Erl, W., Weber, K. S. C., & Weber, P. C. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00324-0 · Cited by 411
(1999) · Taylor & Francis eBooks · doi:10.1201/9781420069006.ch5 · Cited by 322
Grodstein, F., Manson, J. E., & Stampfer, M. J. (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-135-1-200107030-00003 · Cited by 316
Quantitative-Qualitative Friction Ridge Analysis: An Introduction to Basic and Advanced Ridgeology
Ashbaugh, D. R. (1999) · Thammasat University Digital Collections · Cited by 302
Quantitative-Qualitative Friction Ridge Analysis: An Introduction to Basic and Advanced Ridgeology
Ashbaugh, D. R. (1999) · CRC Press eBooks · doi:10.1201/9781420048810 · Cited by 297
Wang, Y., Hu, J., & Phillips, D. (2007) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2007.1003 · Cited by 282
Vehkavaara, S., Silveira, A., Hakala-Ala-Pietilä, T., Virkamäki, A., Hovatta, O., Hamsten, A., Taskinen, M.-R., & Yki-Järvinen, H. (2001) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1615643 · Cited by 270
Fingerprint matching using transformation parameter clustering
Germain, R. S., Califano, A., & Colville, S. (1997) · IEEE Computational Science and Engineering · doi:10.1109/99.641608 · Cited by 246
Koh, K. K., Cardillo, C., Bui, M. N., Hathaway, L., Csako, G., Waclawiw, M. A., Panza, J. A., & Cannon, R. O. (1999) · Circulation · doi:10.1161/01.cir.99.3.354 · Cited by 244
Combining minutiae descriptors for fingerprint matching
Feng, J. (2008) · Pattern Recognition · doi:10.1016/j.patcog.2007.04.016 · Cited by 233
Self-citationA new algorithm for distorted fingerprints matching based on normalized fuzzy similarity measure
Chen, X., Tian, J., & Yang, X. M. (2006) · IEEE Transactions on Image Processing · doi:10.1109/tip.2005.860597 · Cited by 124
Jain, A. K., & Ross, A. A. (2002) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2002.5745550 · Cited by 118
Self-citationA Multispectral Whole-Hand Biometric Authentication System
Rowe, R. K., Uludağ, U., Demirkus, M., Parthasaradhi, S. T. V., & Jain, A. K. (2007) · Biometrics Symposium · doi:10.1109/bcc.2007.4430532 · Cited by 113
Self-citationHerrington, D. M., Brosnihan, K. B., Pusser, B. E., Seely, E. W., Ridker, P. M., Rifai, N., & MacLean, D. B. (2001) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.86.9.7799 · Cited by 79
Automated Fingerprint Identification Systems (AFIS)
Loll, A. (2013) · Encyclopedia of Forensic Sciences · doi:10.1016/b978-0-12-382165-2.00261-0 · Cited by 75
Walsh, B. W., Cox, D. A., Sashegyi, A. I., Dean, R. A., Tracy, R. P., & Anderson, P. W. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)01865-3 · Cited by 71
On matching latent fingerprints
Jain, A. K., Feng, J., Nagar, A., & Nandakumar, K. (2008) · 2009 IEEE Computer Society Conference on Computer Vision and Pattern Recognition Workshops · doi:10.1109/cvprw.2008.4563117 · Cited by 71
Self-citationFeature extraction method for palmprint considering elimination of creases
Funada, J., Ohta, N., Mizoguchi, M., et al. (2002) · Proceedings - International Conference on Pattern Recognition/Proceedings/International Conference on Pattern Recognition · doi:10.1109/icpr.1998.712091 · Cited by 59
Cited by
Human Identification Using Finger Images
Kumar, A., & Zhou, Y. (2012) · IEEE Transactions on Image Processing · doi:10.1109/tip.2011.2171697 · Cited by 624
Zhang, L., Li, L., Yang, A., Shen, Y., & Yang, M. (2017) · Pattern Recognition · doi:10.1016/j.patcog.2017.04.016 · Cited by 294
Human Identification Using Palm-Vein Images
Zhou, Y., & Kumar, A. (2011) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2011.2158423 · Cited by 290
Feature Extraction Methods for Palmprint Recognition: A Survey and Evaluation
Fei, L., Lu, G., Jia, W., Teng, S., & Zhang, D. (2019) · IEEE Transactions on Systems, Man, and Cybernetics: Systems · doi:10.1109/tsmc.2018.2795609 · Cited by 228
Biometric Recognition: An Overview
Jain, A. K., & Kumar, A. (2012) · The International Library of Ethics, Law and Technology · doi:10.1007/978-94-007-3892-8_3 · Cited by 176
Self-citation
Metadata
- Authors
- Jain, A. K., & Feng, J.
- Venue
- IEEE Transactions on Pattern Analysis and Machine Intelligence
- Published
- 2009-06
- Volume
- 31
- Issue
- 6
- Pages
- 1032-1047
- ISSN
- 0162-8828 (ISSN-L)
- OpenAlex
- W2148082513
- Cited by
- 341
- References
- 47
- FWCI
- 33.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.