A PWM Plus Phase-Shift Control Bidirectional DC–DC Converter
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
A pulse-width modulation (PWM) plus phase-shift control bidirectional dc-dc converter is proposed. In this converter, PWM control and phase-shift control are combined to reduce current stress and conduction losses, and to expand ZVS range. The operation principle and analysis of the converter are explained, and ZVS condition is derived. A prototype of PWM plus phase-shift bidirectional dc-dc converter is built to verify the analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Performance characterization of a high-power dual active bridge DC-to-DC converter
Kheraluwala, M. N., Gascoigne, R. W., Divan, D. M., & Baumann, E. D. (1992) · IEEE Transactions on Industry Applications · doi:10.1109/28.175280 · Cited by 1,496
Bi-directional DC to DC converters for fuel cell systems
Wang, K., Lin, C. Y., Zhu, L., Qu, D., Lee, F. C., & Lai, J. S. (2002) · Power Electronics in Transportation (Cat. No.98TH8349) · doi:10.1109/pet.1998.731056 · Cited by 208
A bi-directional DC-DC converter topology for low power application
Jain, M., Jain, P. K., & Daniele, M. (2002) · PESC97. Record 28th Annual IEEE Power Electronics Specialists Conference. Formerly Power Conditioning Specialists Conference 1970-71. Power Processing and Electronic Specialists Conference 1972 · doi:10.1109/pesc.1997.616811 · Cited by 205
Current mode controlled bidirectional flyback converter
Venkatesan, K. (2003) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.1989.48567 · Cited by 87
Bidirectional DC/DC power conversion using constant frequency multi-resonant topology
Martinez, Z. R., & Ray, B. (2002) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.1994.316291 · Cited by 47
Cited by
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Bai, H., & Mi, C. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2005103 · Cited by 1,121
Jung, J.-H., Kim, H.-S., Ryu, M.-H., & Baek, J.-W. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2213346 · Cited by 621
Pwm control of dual active bridge: Comprehensive analysis and experimental verification
Jain, A. K., & Ayyanar, R. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2070519 · Cited by 567
Industrial Electronics for Electric Transportation: Current State-of-the-Art and Future Challenges
Williamson, S. S., Rathore, A. K., & Musavi, F. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2409052 · Cited by 527
Analysis and Design of High-Frequency Isolated Dual-Bridge Series Resonant DC/DC Converter
Li, X., & Bhat, A. K. S. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2034662 · Cited by 493
Transformer-Coupled Multiport ZVS Bidirectional DC–DC Converter With Wide Input Range
Tao, H., Kotsopoulos, A., Duarte, J. L., & Hendrix, M. A. M. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.915129 · Cited by 478
Chen, W., Rong, P., & Lu, Z. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2037099 · Cited by 464
Three-Port Triple-Half-Bridge Bidirectional Converter With Zero-Voltage Switching
Tao, H., Duarte, J. L., & Hendrix, M. A. M. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.915023 · Cited by 404
Fan, H., & Li, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2160652 · Cited by 401
Self-citationResearch on voltage and power balance control for cascaded modular solid-state transformer
Shi, J., Gou, W., Yuan, H., Zhao, T., & Huang, A. Q. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2106803 · Cited by 362
Rodriguez, A., Vazquez, A., Lamar, D. G., Hernando, M. M., & Sebastian, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2309853 · Cited by 352
Zhao, B., Song, Q., Liu, W., & Sun, W. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2210374 · Cited by 345
Bai, H., Nie, Z., & Mi, C. C. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2039648 · Cited by 314
A ZVS Bidirectional DC–DC Converter With Phase-Shift Plus PWM Control Scheme
Xiao, H., & Xie, S. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.915188 · Cited by 299
Optimized Operation of Current-Fed Dual Active Bridge DC–DC Converter for PV Applications
Shi, Y., Li, R., Xue, Y., & Li, H. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2432093 · Cited by 298
Minimum Current Operation of Bidirectional Dual-Bridge Series Resonant DC/DC Converters
Corradini, L., Seltzer, D., Bloomquist, D., Zane, R., Maksimović, D., & Jacobson, B. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2181421 · Cited by 247
Zhang, Y., Gao, Y., Zhou, L., & Sumner, M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2788436 · Cited by 239
Zhang, Z., Ouyang, Z., Thomsen, O. C., & Andersen, M. A. E. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2159515 · Cited by 166
Onar, O. C., Kobayashi, J., Erb, D. C., & Khaligh, A. (2012) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2012.2192459 · Cited by 139
Zhang, Z., Thomsen, O. C., & Andersen, M. A. E. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2134051 · Cited by 102
Minimum-RMS-current operation of asymmetric dual active half-bridge converters with and without ZVS
Chakraborty, S., & Chattopadhyay, S. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2613874 · Cited by 72
A bidirectional three-phase push–pull converter with dual asymmetrical PWM method
Kwon, M., Park, J., & Choi, S. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2431273 · Cited by 47
Analysis and implementation of a bidirectional ZVS dc-dc converter with active clamp
Lin, B.-R., Chen, J.-J., Lee, Y.-E., & Chiang, H.-K. (2008) · 2008 3rd IEEE Conference on Industrial Electronics and Applications · doi:10.1109/iciea.2008.4582544 · Cited by 19
Xu, X., Khambadkone, A. M., & Oruganti, R. (2007) · IECON 2007 - 33rd Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2007.4460246 · Cited by 18
Metadata
- Authors
- Xu, D., Zhao, C., & Fan, H.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2004-05
- Volume
- 19
- Issue
- 3
- Pages
- 666-675
- ISSN
- 0885-8993 (ISSN-L)
- OpenAlex
- W2043183996
- Cited by
- 284
- References
- 5
- FWCI
- 5.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.