Evaluation of Current Controllers for Distributed Power Generation Systems
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
This paper discusses the evaluation of different current controllers employed for grid-connected distributed power generation systems having variable input power, such as wind turbines and photovoltaic systems. The focus is mainly set on linear controllers such as proportional-integral, proportional-resonant, and deadbeat (DB) controllers. Additionally, an improved DB controller robust against grid impedance variation is also presented. Since the paper discusses the implementation of these controllers for grid-connected applications, their evaluation is made in three operating conditions. First, in steady-state conditions, the contribution of controllers to the total harmonic distortion of the grid current is pursued. Further on, the behavior of controllers in the case of transient conditions like input power variations and grid voltage faults is also examined. Experimental results in each case are presented in order to evaluate the performance of the controllers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey
Carrasco, J. M., Franquelo, L. G., Bialasiewicz, J. T., Galvan, E., PortilloGuisado, R. C., Prats, M. A. M., Leon, J. I., & Moreno-Alfonso, N. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878356 · Cited by 4,018
Power electronics as efficient interface in dispersed power generation systems
Blaabjerg, F., Chen, Z., & Kjaer, S. B. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833453 · Cited by 2,588
Self-citationUnderstanding power quality problems: voltage sags and interruptions
(2000) · Choice Reviews Online · doi:10.5860/choice.37-4522 · Cited by 1,791
Grid current regulation of a three-phase voltage source inverter with an LCL input filter
Twining, E., & Holmes, D. G. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810838 · Cited by 901
Yuan, X., Merk, W., Stemmler, H., & Allmeling, J. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/28.993175 · Cited by 896
Grid Code, high and extra high voltage
Netz, E. O. (2006) · Medical Entomology and Zoology · Cited by 835
Flexible Active Power Control of Distributed Power Generation Systems During Grid Faults
Rodriguez, P., Timbus, A. V., Teodorescu, R., Liserre, M., & Blaabjerg, F. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.899914 · Cited by 726
Self-citationYuan, X., Allmeling, J., Merk, W., & Stemmler, H. (2002) · Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129) · doi:10.1109/ias.2000.883122 · Cited by 663
Sato, Y., Ishizuka, T., Nezu, K., & Kataoka, T. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.673717 · Cited by 265
Sato, Y., Ishizuka, T., Nezu, K., & Kataoka, T. (2002) · IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting · doi:10.1109/ias.1997.629051 · Cited by 208
Cited by
Control of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723
Self-citationOlivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137
“A general overview of grid-side converter controllers is given in [54], [64], in which controllers are categorized based on their reference frame: synchronous ( ), stationary ( ), and natural ( ).”
BackgroundFuture on Power Electronics for Wind Turbine Systems
Blaabjerg, F., & Ma, K. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2275978 · Cited by 860
Self-citationAgorreta, J. L., Borrega, M., López, J., & Marroyo, L. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2095429 · Cited by 596
Kim, J.-Y., Jeon, J.-H., Kim, S.-K., Cho, C., Park, J. H., Kim, H.-M., & Nam, K.-Y. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2073488 · Cited by 468
Single-Phase On-Board Bidirectional PEV Charger for V2G Reactive Power Operation
Kisacikoglu, M. C., Kesler, M., & Tolbert, L. M. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2360685 · Cited by 381
“The most inner loop (i-loop) is controlled using a nonideal proportional and resonant (PR) controller [28], [29].”
BackgroundA high-efficiency grid-tie battery energy storage system
Qian, H., Zhang, J., Lai, J.-S., & Yu, W. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2096562 · Cited by 360
Wang, F., Duarte, J. L., & Hendrix, M. A. M. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2052289 · Cited by 327
Novel High Step-Up DC–DC Converter With Coupled-Inductor and Switched-Capacitor Techniques
Hsieh, Y.-P., Chen, J.-F., Liang, T.-J., & Yang, L.-S. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2151828 · Cited by 326
Mohamed, Y. A.-R. I., & Radwan, A. A. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2136362 · Cited by 309
Reyes, M., Rodriguez, P., Vazquez, S., Luna, A., Teodorescu, R., & Carrasco, J. M. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2190147 · Cited by 309
Self-citationSon, J.-Y., & Ma, K. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2695485 · Cited by 295
Novel High Step-Up DC–DC Converter for Distributed Generation System
Hsieh, Y.-P., Chen, J.-F., Liang, T.-J., & Yang, L.-S. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2107721 · Cited by 295
Serban, I., & Marinescu, C. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2283298 · Cited by 274
Cooperative Control of Distributed Energy Storage Systems in a Microgrid
Xu, Y., Zhang, W., Hug, G., Kar, S., & Li, Z. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2354033 · Cited by 265
Miret, J., Castilla, M., Camacho, A., Vicuña, L. G. D., & Matas, J. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2191306 · Cited by 243
Matas, J., Castilla, M., Miret, J., Garcia de Vicuna, L., & Guzman, R. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2274414 · Cited by 233
“Different control schemes can be found in literature to overcome these problems in which the current controller and the employed synchronization technique play an important role [14]–[21].”
BackgroundA New Directional Element for Microgrid Protection
Hooshyar, A., & Iravani, R. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2727400 · Cited by 223
“A generic VSC current control includes feedforward compensation of the VSC filter’s grid-side voltage, Vg, at the outputs of the controllers [14].”
BackgroundJia, J., Yang, G., & Nielsen, A. H. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2682164 · Cited by 219
A Nonlinear-Disturbance-Observer-Based DC-Bus Voltage Control for a Hybrid AC/DC Microgrid
Wang, C., Li, X., Guo, L., & Li, Y. W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2297376 · Cited by 215
Grid Integration of Small-Scale Photovoltaic Systems in Secondary Distribution Network—A Review
Panigrahi, R., Mishra, S. K., Srivastava, S. C., Srivastava, A. K., & Schulz, N. N. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.2979789 · Cited by 214
“A comparison of different current controllers and their advantages and disadvantages is listed in Table IX [80], [83].”
BackgroundClosed-Loop Control of DC–DC Dual-Active-Bridge Converters Driving Single-Phase Inverters
Qin, H., & Kimball, J. W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2257859 · Cited by 212
Overview of AC Microgrid Controls with Inverter-Interfaced Generations
Hossain, M., Pota, H., Issa, W., & Hossain, M. (2017) · Energies · doi:10.3390/en10091300 · Cited by 205
“The main difficulty of the controller is its sensitivity to the network parameters [50].”
Kouadri, A., Hajji, M., Harkat, M.-F., Abodayeh, K., Mansouri, M., Nounou, H., & Nounou, M. (2020) · Renewable Energy · doi:10.1016/j.renene.2020.01.010 · Cited by 159
Xu, J., Xie, S., & Tang, T. (2014) · IET Power Electronics · doi:10.1049/iet-pel.2013.0666 · Cited by 158
Metadata
- Authors
- Timbus, A., Liserre, M., Teodorescu, R., Rodriguez, P., & Blaabjerg, F.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2009-03
- Volume
- 24
- Issue
- 3
- Pages
- 654-664
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2148782894
- Cited by
- 934
- References
- 11
- FWCI
- 93.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.